{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV1200A6603333","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV1200A6603333","canonicalUrl":"https://aoctrl.com/schneider/ATV1200A6603333","factsUrl":"https://aoctrl.com/api/mcp/products/ATV1200A6603333","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 1200 ATV1200A6603333 medium-voltage AC drive, 552 kW, 660 kVA, 18-pulse diode rectifier, 2970...3630 V supply, floor-standing enclosure.","salesMarkdown":"## What this drive handles and where it fits The ATV1200A6603333 is a medium-voltage Altivar 1200 drive rated for 552 kW motor power at 660 kVA apparent power, accepting a supply range of 2970...3630 V. It drives both synchronous and asynchronous motors — common for large pumps, fans, compressors, and conveyors in process plants, water treatment, and mining. The 18-pulse diode rectifier bridge on the input side draws 135 A line current and keeps harmonic distortion low enough to meet IEEE 519 without external filters in most installations. Integrated EMC filter is standard. ## Overload profile and fault handling Standard overload rating holds 1.2× In for 60 s and 1.5× In for 3 s; high overload pushes to 1.5× In for 60 s and 1.85× In for 3 s. This gives headroom for starting high-inertia loads or clearing transient overloads without tripping. The drive withstands a prospective line short-circuit current of 31.5 kA for 150 ms — enough to coordinate with upstream MV switchgear on most distribution networks. Ground-fault protection is built into the drive. ## Cooling, enclosure, and installation constraints The drive ships in a floor-standing enclosure with separate airflows for the transformer and power cells. Forced convection cooling moves 9900 m³/h (standard efficiency) or 13 200 m³/h (high efficiency). Noise level is 80 dB — plan for hearing protection if the drive is in a manned area. Dimensions: 2760 mm wide (3060 mm high-efficiency), 2520 mm tall (2670 mm high-efficiency), 1400 mm deep (1500 mm high-efficiency). Pollution degree 2 per EN/IEC 61800-5-1. ## Auxiliary supplies and control wiring The control electronics require an external 220 V AC supply at 3 kVA; the cooling fan runs on 380 V AC internal supply. Optional external supplies for both are available. Electrical isolation between power and control circuits is standard. Six discrete inputs (10 optional) and four software-configurable analogue inputs (0...20 mA / 4...20 mA, 250 Ω impedance) handle most process signals. One analogue output (same current range) is provided. Dielectric strength between earth and power terminals is 10 kV AC.","metaTitle":"Schneider Electric ATV1200A6603333 AC Drive (VFD) 480V","metaDescription":"Schneider Electric ATV1200A6603333 Altivar 1200 medium-voltage drive, 552 kW, 660 kVA, 18-pulse input. CE marked. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"1400 mm (standard efficiency) 1500 mm (high efficiency)","Width":"2760 mm (standard efficiency) 3060 mm (high efficiency)","title":"ATV1200A6603333","Height":"2520 mm standard efficiency 2670 mm high efficiency","Supply":"External supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)","Marking":"CE","Isolation":"Electrical between power and control","Standards":"EN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1","EMC filter":"Integrated","Input type":"18 pulse diode rectifier bridge","Noise level":"80 dB","Speed range":"20...100","description":"medium voltage variable speed drive ATV1200 - 3.3 kV - 660 kVA","Line current":"135 A","Apparent power":"660 kVA","Assembly style":"In floor-standing enclosure with separate air flows","Motor power kW":"552 kW","Output voltage":"<= power supply voltage","Protection type":"Ground fault protection: drive","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to EN/IEC 61800-5-1","Range of product":"Altivar 1200","Device short name":"ATV1200","Relative humidity":"0...90 % 0...95 % optional","Operating altitude":"1000...2000 m with current derating 0.6 % per 100 m","Operating position":"Vertical +/- 10 degree","Overload withstand":"1.2 In, standard overload, 60 s 1.5 In, standard overload, 3 s 1.5 In, high overload, 60 s 1.85 In, high overload, 3 s","Analogue input type":"software-configurable current: 0...20 mA/4...20 mA, 24 V max, impedance: 250 Ohm","Colour of enclosure":"Grey (RAL 7032)","Dielectric strength":"10 kV AC between earth and power terminals","Product Composition":"2 x plinth Phase-shifting transformer 9 x power cells Medium voltage arrestors Cooling fans Human machine interface","Product destination":"Synchronous motors Asynchronous motors","Analogue output type":"software-configurable current: 0...20 mA/4...20 mA DC, impedance: 250 Ohm","Overvoltage category":"II conforming to EN/IEC 61800-5-1","Prospective line Isc":"31.5 kA for 150 ms","Vibration resistance":"4.9 m/s² (f= 10...50 Hz)","Analogue input number":"4","Discrete input number":"6 10 (optional)","Electrical connection":"Bar - screw type M10, clamping capacity: 6 x 40 mm² (L1/R, L2/S, L3/T) entry from the bottom or from the top","Supply voltage limits":"2970...3630 V","Volume of cooling air":"9900 m3/h (standard efficiency) 13200 m3/h (high efficiency)","Analogue output number":"2 4 (optional)","Discrete output number":"10 14 (optional)","IP degree of protection":"IP42 IP41 IP31","Network number of phases":"3 phases","Continuous output current":"116 A (standard overload) 93 A (high overload)","Maximum transient current":"139 A for 60 s","Product or component type":"Medium voltage variable speed drive","[Us] rated supply voltage":"3.3 kV +/- 10 %","Communication port protocol":"Human machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9","Nominal switching frequency":"600 Hz","Product specific application":"Fan, pump, compressor, conveyor","Speed drive output frequency":"0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback","[Uc] control circuit voltage":"220 V","Synchronous motor control profile":"Voltage/frequency ratio (V/f) Closed-loop control with encoder","Asynchronous motor control profile":"Vector control with sensor, optional Closed-loop control with encoder Sensorless flux vector control Voltage/frequency ratio (V/f)","Acceleration and deceleration ramps":"Linear from 0...3200 s","Ambient air temperature for storage":"-10...60 °C","Ambient air temperature for operation":"0...40 °C 40...50 °C (with current derating of 2 % per °C)","Total Losses At 100 % Load Including Fan Power":"22 kW (standard efficiency) 19 kW (high efficiency)","Drive Efficiency With Transformer (Including Fan Power)":"96 % (standard efficiency) 96.5 % (high efficiency)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/vn/en/product/download-pdf/ATV1200A6603333?filename=Schneider+Electric_Altivar-1200_ATV1200A6603333.pdf', 'path_name': 'dea624be7cc5931ceef593891c823d0e.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/dea624be7cc5931ceef593891c823d0e.pdf', 'status': 1}","sourceUrl":"https://www.se.com/vn/en/product/ATV1200A6603333/medium-voltage-variable-speed-drive-atv1200-3-3-kv-660-kva/"},"ai":{"faq":[{"question":"What is ATV1200A6603333's listed depth and width?","answer":"Depth is 1400 mm (standard efficiency) or 1500 mm (high efficiency). Width is 2760 mm (standard efficiency) or 3060 mm (high efficiency). Height is 2520 mm (standard efficiency) or 2670 mm (high efficiency)."},{"question":"What compliance documentation does Schneider Electric provide for ATV1200A6603333?","answer":"The drive carries CE marking and is designed to EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. Overvoltage category II, pollution degree 2 per EN/IEC 61800-5-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV1200A6603333","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV1200A6603333 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}