{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV1200A66606363","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV1200A66606363","canonicalUrl":"https://aoctrl.com/schneider/ATV1200A66606363","factsUrl":"https://aoctrl.com/api/mcp/products/ATV1200A66606363","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 1200 series, ATV1200A66606363 AC drive, 5016 kW motor power, 36-pulse diode rectifier input, 2970-3630 V supply, floor-standing enclosure.","salesMarkdown":"## What this drive is and what it powers The ATV1200A66606363 is a Schneider Electric Altivar 1200 medium-voltage AC drive rated for 5016 kW motor power, designed for asynchronous motors in heavy industrial applications. It sits in a floor-standing enclosure with separate air flows for the power section and control electronics. The 36-pulse diode rectifier bridge on the input side means this drive draws line current with low harmonic distortion — 550 A line current at 6000 kVA apparent power — which keeps the upstream transformer and switchgear from overheating on harmonic-rich loads. ## Physical size and site planning This is a large unit: 3040 mm tall, 8570 mm wide, 1800 mm deep. The volume of cooling air required is 90,000 m³/h, so the installation room needs substantial ventilation or ducted exhaust. Forced-convection cooling with separate air flows means the power cell heat is rejected directly rather than warming the control cabinet. ## Overload capability and protection Standard overload rating: 1.2× rated current for 60 seconds, or 1.5× for 3 seconds. High overload profile: 1.5× for 60 seconds, 1.85× for 3 seconds. This matters when the driven load has a heavy breakaway torque or a short-duration peak — a crusher or a centrifuge, for example — because the drive holds torque through the transient without tripping. Ground fault protection is built into the drive, and the prospective short-circuit current withstand is 31.5 kA for 150 ms. Dielectric strength between earth and power terminals is 20 kV AC. The pollution degree is 2 per EN/IEC 61800-5-1, which covers the normal industrial environment with non-conductive dust. ## Control supply and I/O The control electronics need an external 220 V AC supply rated at 3 kVA. There is also an optional external 220 V AC/DC supply. The cooling fans run on a separate 380 V AC supply — this separation means you can keep the control alive while the main power is off, which helps during commissioning and fault-finding. Four software-configurable analogue inputs (0-20 mA / 4-20 mA, 250 Ω impedance) and one analogue output (same range). Six discrete inputs standard, expandable to ten. The I/O is electrically isolated from the power stage, so field wiring faults on the control side won't propagate into the drive's power section. CE marked, with integrated EMC filter. Standards compliance includes EN/IEC 60204-11 (electrical equipment of machines), EN/IEC 60529 (IP enclosure), EN/IEC 61800-3 (EMC for drives), EN/IEC 61800-4 (drive performance), and EN/IEC 61800-5-1 (electrical safety). Overvoltage category II per the same safety standard.","metaTitle":"Schneider Electric ATV1200A66606363 AC Drive, 5016 kW","metaDescription":"Schneider Electric ATV1200A66606363 Altivar 1200 AC drive, 5016 kW motor power, 36-pulse input, 2970-3630 V supply. CE marked, active production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"1800 mm (standard efficiency)","Width":"8570 mm (standard efficiency)","title":"ATV1200A66606363","Height":"3040 mm standard efficiency","Supply":"External supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)","Marking":"CE","Isolation":"Electrical between power and control","Standards":"EN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1","EMC filter":"Integrated","Input type":"36 pulse diode rectifier bridge","Noise level":"80 dB","Speed range":"20...100","description":"medium voltage variable speed drive ATV1200 - 6.3 kV - 6000 kVA","Line current":"550 A","Apparent power":"6000 kVA","Assembly style":"In floor-standing enclosure with separate air flows","Motor power kW":"5016 kW","Output voltage":"<= power supply voltage","Protection type":"Ground fault protection: drive","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to EN/IEC 61800-5-1","Range of product":"Altivar 1200","Device short name":"ATV1200","Relative humidity":"0...90 % 0...95 % optional","Operating altitude":"1000...2000 m with current derating 0.6 % per 100 m","Operating position":"Vertical +/- 10 degree","Overload withstand":"1.2 In, standard overload, 60 s 1.5 In, standard overload, 3 s 1.5 In, high overload, 60 s 1.85 In, high overload, 3 s","Analogue input type":"software-configurable current: 0...20 mA/4...20 mA, 24 V max, impedance: 250 Ohm","Colour of enclosure":"Grey (RAL 7032)","Dielectric strength":"20 kV AC between earth and power terminals","Product Composition":"2 x plinth Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface 18 x power cells","Product destination":"Asynchronous motors","Analogue output type":"software-configurable current: 0...20 mA/4...20 mA DC, impedance: 250 Ohm","Overvoltage category":"II conforming to EN/IEC 61800-5-1","Prospective line Isc":"31.5 kA for 150 ms","Vibration resistance":"4.9 m/s² (f= 10...50 Hz)","Analogue input number":"4","Discrete input number":"6 10 (optional)","Electrical connection":"Bar - screw type M10, clamping capacity: 6 x 40 mm² (L1/R, L2/S, L3/T) entry from the bottom or from the top","Supply voltage limits":"2970...3630 V","Volume of cooling air":"90000 m3/h (standard efficiency)","Analogue output number":"2 4 (optional)","Discrete output number":"10 14 (optional)","IP degree of protection":"IP31 IP41 IP42","Network number of phases":"3 phases","Continuous output current":"550 A (standard overload) 440 A (high overload)","Maximum transient current":"660 A for 60 s","Product or component type":"Medium voltage variable speed drive","[Us] rated supply voltage":"6.3 kV +/- 10 %","Communication port protocol":"Human machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9","Nominal switching frequency":"600 Hz","Product specific application":"Fan, pump, compressor, conveyor","Speed drive output frequency":"0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback","[Uc] control circuit voltage":"220 V","Synchronous motor control profile":"Closed-loop control with encoder Voltage/frequency ratio (V/f)","Asynchronous motor control profile":"Closed-loop control with encoder Sensorless flux vector control Voltage/frequency ratio (V/f) Vector control with sensor, optional","Acceleration and deceleration ramps":"Linear from 0...3200 s","Ambient air temperature for storage":"-10...60 °C","Ambient air temperature for operation":"0...40 °C 40...50 °C (with current derating of 2 % per °C)","Total Losses At 100 % Load Including Fan Power":"186 kW (standard efficiency)","Drive Efficiency With Transformer (Including Fan Power)":"96 % (standard efficiency)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/vn/en/product/download-pdf/ATV1200A66606363?filename=Schneider+Electric_Altivar-1200_ATV1200A66606363.pdf', 'path_name': '167dcc2e5ec9f5820e75e1fcd795e4bf.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/167dcc2e5ec9f5820e75e1fcd795e4bf.pdf', 'status': 1}","sourceUrl":"https://www.se.com/vn/en/product/ATV1200A66606363/medium-voltage-variable-speed-drive-atv1200-6-3-kv-6000-kva/"},"ai":{"faq":[{"question":"What supply voltage does the ATV1200A66606363 need?","answer":"The supply voltage limits are 2970 to 3630 V AC. The input is a 36-pulse diode rectifier bridge drawing 550 A line current at 6000 kVA apparent power."},{"question":"What overload ratings does this drive support?","answer":"Standard overload: 1.2× rated current for 60 seconds or 1.5× for 3 seconds. High overload: 1.5× for 60 seconds or 1.85× for 3 seconds. This gives flexibility for applications with high breakaway torque or short-duration peak loads."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV1200A66606363","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV1200A66606363 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}