{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV1200A71001010","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV1200A71001010","canonicalUrl":"https://aoctrl.com/schneider/ATV1200A71001010","factsUrl":"https://aoctrl.com/api/mcp/products/ATV1200A71001010","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 1200 ATV1200A71001010 AC drive, 5936 kW motor power, 7100 kVA apparent power, 48-pulse diode rectifier, floor-standing enclosure.","salesMarkdown":"## What this drive delivers for a medium-voltage motor line The ATV1200A71001010 is a Schneider Electric Altivar 1200 AC drive rated for 5936 kW motor power with 7100 kVA apparent power — sized for large asynchronous motor loads like pumps, fans, and compressors in medium-voltage installations. It draws 410 A line current from a 2970–3630 V supply through a 48-pulse diode rectifier bridge, which keeps input harmonics low enough to meet EN/IEC 61800-3 without external filtering. ## Overload profile and fault handling Standard overload rating holds 1.2× rated current for 60 seconds and 1.5× for 3 seconds; a high-overload setting pushes to 1.5× for 60 seconds and 1.85× for 3 seconds — choose the profile that matches your motor's starting duty cycle. The drive withstands a prospective line fault of 31.5 kA for 150 ms, so it coordinates with upstream protection without requiring a separate current-limiting reactor in most medium-voltage switchgear arrangements. Ground fault protection is built into the drive, and the dielectric strength between earth and power terminals is 28 kV AC — a margin that supports direct connection to ungrounded or resistance-grounded distribution systems. ## Physical footprint and installation constraints The drive ships in a floor-standing enclosure measuring 3040 mm high by 9370 mm wide by 1700 mm deep — plan for a dedicated equipment room with a reinforced floor and overhead lifting access. Forced convection cooling moves 66400 m³/h of air; the enclosure separates internal airflows so the power cells and transformer each get their own thermal path — ducting to a plant exhaust system is recommended to avoid recirculating 80 dB noise. Power connections use M10 screw-type bars accepting up to 6 × 40 mm² cable per phase, entry from top or bottom — coordinate the gland plate and cable tray layout before the enclosure arrives on site. ## System composition and control wiring The ATV1200A71001010 includes two plinths, a phase-shifting transformer, medium-voltage arrestors, cooling fans, a human-machine interface, and 24 power cells — it arrives as a near-complete drive system, not a bare chassis. Control power requires an external 220 V AC supply at 3 kVA; the internal fan supply is 380 V AC. Optional external control supply at 220 V AC/DC and optional external fan supply at 380 V AC allow separate upstream UPS feeds for the control electronics. Four software-configurable analogue inputs (0–20 mA / 4–20 mA, 250 Ω impedance) and six discrete inputs (expandable to ten) handle speed reference and run commands — the I/O count is modest for a drive of this class, so plan for a remote I/O rack if the application needs more than a few signals. ## Compliance and environmental limits CE marked and designed to EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1 — covers electrical safety, EMC, and enclosure protection for industrial drive installations. Pollution degree 2 per EN/IEC 61800-5-1 and overvoltage category II — the drive is intended for a clean, controlled environment (no conductive dust or condensation). Relative humidity range is 0–90 % (0–95 % optional), and the drive must be mounted vertically within ±10° — factor this into the enclosure layout and HVAC design.","metaTitle":"Schneider Electric ATV1200A71001010 Altivar 1200 VFD","metaDescription":"Schneider Electric ATV1200A71001010 Altivar 1200 AC drive, 5936 kW motor power, 7100 kVA apparent power, 48-pulse input. CE marked. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"1700 mm (standard efficiency)","Width":"9370 mm (standard efficiency)","Height":"3040 mm standard efficiency","Current":"410 A","IP Rating":"IP31 / IP42 / IP41","Input Type":"48 pulse diode rectifier bridge","Coil Voltage":"220 V","Product Status":"Active","Protection Type":"Ground fault protection: drive","Pollution Degree":"Pollution degree 2","Temp Storage Max":"60 °C","Temp Storage Min":"-10 °C","Operating Position":"Vertical +/- 10 degree","Temp Operating Max":"50 °C","Temp Operating Min":"0 °C","Temperature Storage":"-10...60 °C","Ambient Air Temperature Operation":"0...40 °C 40...50 °C (with current derating of 2 % per °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/uk/en/product/ATV1200A71001010/medium-voltage-variable-speed-drive-atv1200-10-kv-7100-kva/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ATV1200A71001010/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV1200A71001010","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV1200A71001010 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}