{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV1200A71001010","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV1200A71001010","canonicalUrl":"https://aoctrl.com/schneider/ATV1200A71001010","factsUrl":"https://aoctrl.com/api/mcp/products/ATV1200A71001010","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 1200 ATV1200A71001010 AC drive, 5936 kW motor power, 7100 kVA apparent power, 48-pulse diode rectifier, floor-standing enclosure.","salesMarkdown":"## What this drive delivers for a medium-voltage motor line The ATV1200A71001010 is a Schneider Electric Altivar 1200 AC drive rated for 5936 kW motor power with 7100 kVA apparent power — sized for large asynchronous motor loads like pumps, fans, and compressors in medium-voltage installations. It draws 410 A line current from a 2970–3630 V supply through a 48-pulse diode rectifier bridge, which keeps input harmonics low enough to meet EN/IEC 61800-3 without external filtering. ## Overload profile and fault handling Standard overload rating holds 1.2× rated current for 60 seconds and 1.5× for 3 seconds; a high-overload setting pushes to 1.5× for 60 seconds and 1.85× for 3 seconds — choose the profile that matches your motor's starting duty cycle. The drive withstands a prospective line fault of 31.5 kA for 150 ms, so it coordinates with upstream protection without requiring a separate current-limiting reactor in most medium-voltage switchgear arrangements. Ground fault protection is built into the drive, and the dielectric strength between earth and power terminals is 28 kV AC — a margin that supports direct connection to ungrounded or resistance-grounded distribution systems. ## Physical footprint and installation constraints The drive ships in a floor-standing enclosure measuring 3040 mm high by 9370 mm wide by 1700 mm deep — plan for a dedicated equipment room with a reinforced floor and overhead lifting access. Forced convection cooling moves 66400 m³/h of air; the enclosure separates internal airflows so the power cells and transformer each get their own thermal path — ducting to a plant exhaust system is recommended to avoid recirculating 80 dB noise. Power connections use M10 screw-type bars accepting up to 6 × 40 mm² cable per phase, entry from top or bottom — coordinate the gland plate and cable tray layout before the enclosure arrives on site. ## System composition and control wiring The ATV1200A71001010 includes two plinths, a phase-shifting transformer, medium-voltage arrestors, cooling fans, a human-machine interface, and 24 power cells — it arrives as a near-complete drive system, not a bare chassis. Control power requires an external 220 V AC supply at 3 kVA; the internal fan supply is 380 V AC. Optional external control supply at 220 V AC/DC and optional external fan supply at 380 V AC allow separate upstream UPS feeds for the control electronics. Four software-configurable analogue inputs (0–20 mA / 4–20 mA, 250 Ω impedance) and six discrete inputs (expandable to ten) handle speed reference and run commands — the I/O count is modest for a drive of this class, so plan for a remote I/O rack if the application needs more than a few signals. ## Compliance and environmental limits CE marked and designed to EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1 — covers electrical safety, EMC, and enclosure protection for industrial drive installations. Pollution degree 2 per EN/IEC 61800-5-1 and overvoltage category II — the drive is intended for a clean, controlled environment (no conductive dust or condensation). Relative humidity range is 0–90 % (0–95 % optional), and the drive must be mounted vertically within ±10° — factor this into the enclosure layout and HVAC design.","metaTitle":"Schneider Electric ATV1200A71001010 Altivar 1200 VFD","metaDescription":"Schneider Electric ATV1200A71001010 Altivar 1200 AC drive, 5936 kW motor power, 7100 kVA apparent power, 48-pulse input. CE marked. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"1700 mm (standard efficiency)","Width":"9370 mm (standard efficiency)","title":"ATV1200A71001010","Height":"3040 mm standard efficiency","Supply":"External supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)","Marking":"CE","Isolation":"Electrical between power and control","Standards":"EN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1","EMC filter":"Integrated","Input type":"48 pulse diode rectifier bridge","Noise level":"80 dB","Speed range":"20...100","description":"medium voltage variable speed drive ATV1200 - 10 kV - 7100 kVA","Line current":"410 A","Apparent power":"7100 kVA","Assembly style":"In floor-standing enclosure with separate air flows","Motor power kW":"5936 kW","Output voltage":"<= power supply voltage","Protection type":"Ground fault protection: drive","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to EN/IEC 61800-5-1","Range of product":"Altivar 1200","Device short name":"ATV1200","Relative humidity":"0...90 % 0...95 % optional","Operating altitude":"1000...2000 m with current derating 0.6 % per 100 m","Operating position":"Vertical +/- 10 degree","Overload withstand":"1.2 In, standard overload, 60 s 1.5 In, standard overload, 3 s 1.5 In, high overload, 60 s 1.85 In, high overload, 3 s","Analogue input type":"software-configurable current: 0...20 mA/4...20 mA, 24 V max, impedance: 250 Ohm","Colour of enclosure":"Grey (RAL 7032)","Dielectric strength":"28 kV AC between earth and power terminals","Product Composition":"2 x plinth Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface 24 x power cells","Product destination":"Asynchronous motors","Analogue output type":"software-configurable current: 0...20 mA/4...20 mA DC, impedance: 250 Ohm","Overvoltage category":"II conforming to EN/IEC 61800-5-1","Prospective line Isc":"31.5 kA for 150 ms","Vibration resistance":"4.9 m/s² (f= 10...50 Hz)","Analogue input number":"4","Discrete input number":"6 10 (optional)","Electrical connection":"Bar - screw type M10, clamping capacity: 6 x 40 mm² (L1/R, L2/S, L3/T) entry from the bottom or from the top","Supply voltage limits":"2970...3630 V","Volume of cooling air":"66400 m3/h (standard efficiency)","Analogue output number":"2 4 (optional)","Discrete output number":"10 14 (optional)","IP degree of protection":"IP31 IP42 IP41","Network number of phases":"3 phases","Continuous output current":"410 A (standard overload) 328 A (high overload)","Maximum transient current":"492 A for 60 s","Product or component type":"Medium voltage variable speed drive","[Us] rated supply voltage":"10 kV +/- 10 %","Communication port protocol":"Human machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9","Nominal switching frequency":"600 Hz","Product specific application":"Fan, pump, compressor, conveyor","Speed drive output frequency":"0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback","[Uc] control circuit voltage":"220 V","Synchronous motor control profile":"Closed-loop control with encoder Voltage/frequency ratio (V/f)","Asynchronous motor control profile":"Voltage/frequency ratio (V/f) Sensorless flux vector control Vector control with sensor, optional Closed-loop control with encoder","Acceleration and deceleration ramps":"Linear from 0...3200 s","Ambient air temperature for storage":"-10...60 °C","Ambient air temperature for operation":"0...40 °C 40...50 °C (with current derating of 2 % per °C)","Total Losses At 100 % Load Including Fan Power":"220 kW (standard efficiency)","Drive Efficiency With Transformer (Including Fan Power)":"96 % (standard efficiency)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/uk/en/product/download-pdf/ATV1200A71001010?filename=Schneider+Electric_Altivar-1200_ATV1200A71001010.pdf', 'path_name': 'bfb4139d2fc8762fa4dc0d7361b807d5.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/bfb4139d2fc8762fa4dc0d7361b807d5.pdf', 'status': 1}","sourceUrl":"https://www.se.com/uk/en/product/ATV1200A71001010/medium-voltage-variable-speed-drive-atv1200-10-kv-7100-kva/"},"ai":{"faq":[{"question":"What compliance documentation does Schneider Electric provide for the ATV1200A71001010?","answer":"The drive carries CE marking and is designed to EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. These cover electrical safety, EMC, enclosure protection, and drive-specific performance standards. No RoHS, REACH, or UL listing is stated in the available documentation."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV1200A71001010","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV1200A71001010 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}