{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV1200A7206363","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV1200A7206363","canonicalUrl":"https://aoctrl.com/schneider/ATV1200A7206363","factsUrl":"https://aoctrl.com/api/mcp/products/ATV1200A7206363","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 1200 series, ATV1200A7206363, medium-voltage AC drive, 443 kW motor power, 530 kVA apparent power, 2970–3630 V supply, 36-pulse diode rectifier, floor-standing enclosure.","salesMarkdown":"## 36-pulse medium-voltage drive for synchronous and asynchronous motors The ATV1200A7206363 is a Schneider Electric Altivar 1200 series AC drive rated for 443 kW motor power and 530 kVA apparent power, supplied from a 2970–3630 V three-phase line. The 36-pulse diode rectifier front end keeps input harmonics low enough that a separate harmonic filter is often unnecessary on the line side — a real advantage for installations where the utility imposes strict THID limits. It drives both synchronous and asynchronous motors. The output voltage follows the supply voltage, so the motor insulation system sees a voltage determined by the incoming line, not a boosted DC bus — a consideration when retrofitting into an existing winding class. ## Overload profiles and short-circuit coordination Standard overload is 1.2× In for 60 s or 1.5× In for 3 s; high overload allows 1.5× In for 60 s or 1.85× In for 3 s. The prospective line Isc is 31.5 kA for 150 ms — the upstream protection must clear within that window to keep the drive's semiconductor fuses intact. The drive is assembled in a floor-standing enclosure with separate air flows for the transformer and power cells. Forced convection cooling moves 16500 m³/h in the high-efficiency variant and 13200 m³/h in the standard-efficiency build. The noise level is 80 dB — ear protection zones around the enclosure are expected. The product composition includes two plinths, a phase-shifting transformer, medium-voltage arrestors, cooling fans, an HMI, and 18 power cells. This multi-cell topology is what enables the 36-pulse input and also provides a degree of fault tolerance — a failed cell can be bypassed while the drive continues running at reduced capacity. ## Physical footprint and site preparation The enclosure dimensions vary by efficiency class: standard efficiency is 3060 mm wide × 1400 mm deep × 2520 mm high; high efficiency is 3360 mm wide × 1500 mm deep × 2670 mm high. The operating position is vertical ±10°. Floor loading and overhead clearance for transformer removal need to be confirmed before the unit arrives on site. Power connection is via M10 screw-type bars accepting up to 6 × 40 mm² cable per phase, entry from the top or bottom. The control supply can be 220 V AC at 3 kVA externally, with an optional 220 V AC/DC supply; the cooling fan has its own 380 V AC supply, also optional. ## Standards, isolation, and environmental limits CE marked, designed to EN/IEC 61800-3 (EMC), EN/IEC 61800-4 (harmonics), and EN/IEC 61800-5-1 (safety). Electrical isolation between power and control circuits. Dielectric strength is 20 kV AC between earth and power terminals. Operating altitude is 1000–2000 m with a 0.6 % current derating per 100 m above 1000 m. Relative humidity range is 0–90 % (0–95 % optional). Vibration resistance is 4.9 m/s² at 10–50 Hz. ## I/O complement and control supply Four software-configurable analogue inputs (0–20 mA / 4–20 mA, 24 V max, 250 Ω impedance) and one analogue output (same current range, 250 Ω impedance). Six discrete inputs standard, expandable to ten. Listed as current production.","metaTitle":"Schneider Electric ATV1200A7206363 Altivar 1200, 443 kW","metaDescription":"Schneider Electric ATV1200A7206363 AC drive, 443 kW / 530 kVA, 2970–3630 V input, 36-pulse rectifier, CE marked. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"1400 mm (standard efficiency) 1500 mm (high efficiency)","Width":"3360 mm (high efficiency) 3060 mm (standard efficiency)","title":"ATV1200A7206363","Height":"2520 mm standard efficiency 2670 mm high efficiency","Supply":"External supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)","Marking":"CE","Isolation":"Electrical between power and control","Standards":"EN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1","EMC filter":"Integrated","Input type":"36 pulse diode rectifier bridge","Noise level":"80 dB","Speed range":"20...100","description":"medium voltage variable speed drive ATV1200 - 6.3 kV - 530 kVA","Line current":"65 A","Apparent power":"530 kVA","Assembly style":"In floor-standing enclosure with separate air flows","Motor power kW":"443 kW","Output voltage":"<= power supply voltage","Protection type":"Ground fault protection: drive","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to EN/IEC 61800-5-1","Range of product":"Altivar 1200","Device short name":"ATV1200","Relative humidity":"0...90 % 0...95 % optional","Operating altitude":"1000...2000 m with current derating 0.6 % per 100 m","Operating position":"Vertical +/- 10 degree","Overload withstand":"1.2 In, standard overload, 60 s 1.5 In, standard overload, 3 s 1.5 In, high overload, 60 s 1.85 In, high overload, 3 s","Analogue input type":"software-configurable current: 0...20 mA/4...20 mA, 24 V max, impedance: 250 Ohm","Colour of enclosure":"Grey (RAL 7032)","Dielectric strength":"20 kV AC between earth and power terminals","Product Composition":"2 x plinth Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface 18 x power cells","Product destination":"Synchronous motors Asynchronous motors","Analogue output type":"software-configurable current: 0...20 mA/4...20 mA DC, impedance: 250 Ohm","Overvoltage category":"II conforming to EN/IEC 61800-5-1","Prospective line Isc":"31.5 kA for 150 ms","Vibration resistance":"4.9 m/s² (f= 10...50 Hz)","Analogue input number":"4","Discrete input number":"6 10 (optional)","Electrical connection":"Bar - screw type M10, clamping capacity: 6 x 40 mm² (L1/R, L2/S, L3/T) entry from the bottom or from the top","Supply voltage limits":"2970...3630 V","Volume of cooling air":"16500 m3/h (high efficiency) 13200 m3/h (standard efficiency)","Analogue output number":"2 4 (optional)","Discrete output number":"10 14 (optional)","IP degree of protection":"IP42 IP31 IP41","Network number of phases":"3 phases","Continuous output current":"49 A (standard overload) 39 A (high overload)","Maximum transient current":"59 A for 60 s","Product or component type":"Medium voltage variable speed drive","[Us] rated supply voltage":"6.3 kV +/- 10 %","Communication port protocol":"Human machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9","Nominal switching frequency":"600 Hz","Product specific application":"Fan, pump, compressor, conveyor","Speed drive output frequency":"0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback","[Uc] control circuit voltage":"220 V","Synchronous motor control profile":"Closed-loop control with encoder Voltage/frequency ratio (V/f)","Asynchronous motor control profile":"Sensorless flux vector control Voltage/frequency ratio (V/f) Vector control with sensor, optional Closed-loop control with encoder","Acceleration and deceleration ramps":"Linear from 0...3200 s","Ambient air temperature for storage":"-10...60 °C","Ambient air temperature for operation":"0...40 °C 40...50 °C (with current derating of 2 % per °C)","Total Losses At 100 % Load Including Fan Power":"16 kW (high efficiency) 18 kW (standard efficiency)","Drive Efficiency With Transformer (Including Fan Power)":"96 % (standard efficiency) 96.5 % (high efficiency)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/vn/en/product/download-pdf/ATV1200A7206363?filename=Schneider+Electric_Altivar-1200_ATV1200A7206363.pdf', 'path_name': 'c4d97e9e99a164c3ec54dfcc86df5f4c.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/c4d97e9e99a164c3ec54dfcc86df5f4c.pdf', 'status': 1}","sourceUrl":"https://www.se.com/vn/en/product/ATV1200A7206363/medium-voltage-variable-speed-drive-atv1200-6-3-kv-530-kva/"},"ai":{"faq":[{"question":"What are the key electrical ratings of the ATV1200A7206363?","answer":"Motor power is 443 kW, apparent power is 530 kVA, supply voltage range is 2970–3630 V, and the input is a 36-pulse diode rectifier bridge."},{"question":"What compliance documentation does the ATV1200A7206363 carry?","answer":"CE marked, designed to EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV1200A7206363","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV1200A7206363 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}