{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV1200A75006060","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV1200A75006060","canonicalUrl":"https://aoctrl.com/schneider/ATV1200A75006060","factsUrl":"https://aoctrl.com/api/mcp/products/ATV1200A75006060","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 1200 ATV1200A75006060 medium-voltage AC drive, 6270 kW motor power, 2970-3630 V supply, 30-pulse diode rectifier, floor-standing enclosure.","salesMarkdown":"## 6270 kW at 3.3 kV — the load this drive carries The ATV1200A75006060 is rated for 6270 kW motor power on synchronous or asynchronous machines, fed from a 2970–3630 V supply. That puts it squarely in the medium-voltage drive class — not a 480 V unit you bolt to a wall, but a floor-standing installation that needs a dedicated transformer and switchgear upstream. Apparent power is 7500 kVA at 720 A line current, which is what you hand to the electrical contractor for cable and breaker sizing. The 30-pulse diode rectifier front end keeps input harmonics low enough that you can skip external filters in most installations. Standard overload rating holds 1.2× rated current for 60 seconds and 1.5× for 3 seconds; the high-overload profile pushes to 1.5× for 60 seconds and 1.85× for 3 seconds. For a crusher or centrifuge application where the peak torque window is short, the high-overload curve gives you headroom without oversizing the drive frame. Prospective short-circuit current withstand is 31.5 kA for 150 ms. That sets the upstream breaker coordination — the drive can ride through a fault on the line side long enough for the feeder breaker to clear, but the protection engineer needs to confirm the let-through energy stays within the drive's rating. ## Physical footprint and cooling — plan the room before the drive arrives The enclosure measures 3040 mm high × 8970 mm wide × 1700 mm deep in standard efficiency configuration. That is a substantial floor footprint — you are not sliding this into an existing panel. The floor-standing enclosure routes separate air flows for power components and control, with forced-convection cooling moving 90,000 m³/h of air. Operating altitude above 1000 m requires derating 0.6 % per 100 m up to 2000 m. If your site is at 1500 m, budget a 3 % current reduction. The drive is rated for vertical installation within ±10° and vibration up to 4.9 m/s² at 10–50 Hz. ## Lifecycle and compliance — active production, CE marked Dielectric strength between earth and power terminals is 20 kV AC. Electrical isolation between power and control circuits is standard. The integrated EMC filter covers conducted emissions for the drive's power range. ## Control wiring and I/O complement The drive ships with 4 software-configurable analogue inputs (0–20 mA / 4–20 mA, 24 V max, 250 Ω impedance) and 1 analogue output of the same type. Discrete inputs are 6 standard, expandable to 10 with an option. Control supply is 220 V AC at 3 kVA, with an optional 220 V AC/DC external supply; the cooling fan runs on 380 V AC internal or optional external supply. The HMI is included in the product composition, along with the phase-shifting transformer, medium-voltage arrestors, and 15 power cells.","metaTitle":"Schneider ATV1200A75006060 AC Drive, 6270 kW, 2970-3630 V","metaDescription":"Schneider Electric Altivar 1200 medium-voltage VFD, 6270 kW motor power, 30-pulse rectifier, CE marked. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"1700 mm (standard efficiency)","Width":"8970 mm (standard efficiency)","title":"ATV1200A75006060","Height":"3040 mm standard efficiency","Supply":"External supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)","Marking":"CE","Isolation":"Electrical between power and control","Standards":"EN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1","EMC filter":"Integrated","Input type":"30 pulse diode rectifier bridge","Noise level":"80 dB","Speed range":"20...100","description":"medium voltage variable speed drive ATV1200 - 6 kV - 7500 kVA","Line current":"720 A","Apparent power":"7500 kVA","Assembly style":"In floor-standing enclosure with separate air flows","Motor power kW":"6270 kW","Output voltage":"<= power supply voltage","Protection type":"Ground fault protection: drive","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to EN/IEC 61800-5-1","Range of product":"Altivar 1200","Device short name":"ATV1200","Relative humidity":"0...90 % 0...95 % optional","Operating altitude":"1000...2000 m with current derating 0.6 % per 100 m","Operating position":"Vertical +/- 10 degree","Overload withstand":"1.2 In, standard overload, 60 s 1.5 In, standard overload, 3 s 1.5 In, high overload, 60 s 1.85 In, high overload, 3 s","Analogue input type":"software-configurable current: 0...20 mA/4...20 mA, 24 V max, impedance: 250 Ohm","Colour of enclosure":"Grey (RAL 7032)","Dielectric strength":"20 kV AC between earth and power terminals","Product Composition":"2 x plinth Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface 15 x power cells","Product destination":"Synchronous motors Asynchronous motors","Analogue output type":"software-configurable current: 0...20 mA/4...20 mA DC, impedance: 250 Ohm","Overvoltage category":"II conforming to EN/IEC 61800-5-1","Prospective line Isc":"31.5 kA for 150 ms","Vibration resistance":"4.9 m/s² (f= 10...50 Hz)","Analogue input number":"4","Discrete input number":"6 10 (optional)","Electrical connection":"Bar - screw type M10, clamping capacity: 6 x 40 mm² (L1/R, L2/S, L3/T) entry from the bottom or from the top","Supply voltage limits":"2970...3630 V","Volume of cooling air":"90000 m3/h (standard efficiency)","Analogue output number":"2 4 (optional)","Discrete output number":"10 14 (optional)","IP degree of protection":"IP42 IP31 IP41","Network number of phases":"3 phases","Continuous output current":"720 A (standard overload) 576 A (high overload)","Maximum transient current":"864 A for 60 s","Product or component type":"Medium voltage variable speed drive","[Us] rated supply voltage":"6 kV +/- 10 %","Communication port protocol":"Human machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9","Nominal switching frequency":"600 Hz","Product specific application":"Fan, pump, compressor, conveyor","Speed drive output frequency":"0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback","[Uc] control circuit voltage":"220 V","Synchronous motor control profile":"Voltage/frequency ratio (V/f) Closed-loop control with encoder","Asynchronous motor control profile":"Voltage/frequency ratio (V/f) Vector control with sensor, optional Sensorless flux vector control Closed-loop control with encoder","Acceleration and deceleration ramps":"Linear from 0...3200 s","Ambient air temperature for storage":"-10...60 °C","Ambient air temperature for operation":"0...40 °C 40...50 °C (with current derating of 2 % per °C)","Total Losses At 100 % Load Including Fan Power":"219 kW (standard efficiency)","Drive Efficiency With Transformer (Including Fan Power)":"96 % (standard efficiency)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/vn/en/product/download-pdf/ATV1200A75006060?filename=Schneider+Electric_Altivar-1200_ATV1200A75006060.pdf', 'path_name': 'd4bd1966cd153af5dd9116c997cc89ae.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/d4bd1966cd153af5dd9116c997cc89ae.pdf', 'status': 1}","sourceUrl":"https://www.se.com/vn/en/product/ATV1200A75006060/medium-voltage-variable-speed-drive-atv1200-6-kv-7500-kva/"},"ai":{"faq":[{"question":"What compliance documentation does Schneider provide for the ATV1200A75006060?","answer":"The drive carries CE marking and complies with EN/IEC 60204-11, 60529, 61800-3, 61800-4, and 61800-5-1. The manufacturer provides a declaration of conformity and the relevant test reports as part of the documentation package."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV1200A75006060","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV1200A75006060 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}