{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV1200A7506666","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV1200A7506666","canonicalUrl":"https://aoctrl.com/schneider/ATV1200A7506666","factsUrl":"https://aoctrl.com/api/mcp/products/ATV1200A7506666","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 1200 series, ATV1200A7506666 AC Drive, 627 kW motor power, 750 kVA apparent power, 36-pulse diode rectifier, 2970...3630 V supply, floor-standing enclosure.","salesMarkdown":"## 627 kW medium-voltage drive for asynchronous motors The Schneider Electric ATV1200A7506666 is a medium-voltage Altivar 1200 drive rated for 627 kW motor power at 750 kVA apparent power, fed from a 2970...3630 V supply through a 36-pulse diode rectifier bridge. It drives asynchronous motors in a floor-standing enclosure with separate air flows for the power cells and transformer — the forced-convection cooling moves 13200 m³/h in the standard-efficiency configuration, 19800 m³/h in the high-efficiency build. The 36-pulse front end keeps line-side harmonics low enough to meet IEEE 519 without a separate filter in most installations — a real advantage when the plant power system is shared with sensitive loads. ## Overload capability and fault tolerance Standard overload rating is 1.2× In for 60 s and 1.5× In for 3 s; the high-overload profile steps to 1.5× In for 60 s and 1.85× In for 3 s — enough to start a loaded conveyor or roll table without tripping on inrush. Prospective line short-circuit current is rated at 31.5 kA for 150 ms, and the drive includes integral ground-fault protection on the output side. Dielectric strength between earth and power terminals is 20 kV AC, with pollution degree II per EN/IEC 61800-5-1 — the insulation system handles the voltage stress of a 3.3 kV-class drive in a mill environment. ## Physical footprint and integration The standard-efficiency unit measures 3060 mm wide × 1400 mm deep × 2520 mm high; the high-efficiency version is 3360 mm wide × 1500 mm deep × 2670 mm high — plan the substation floor space accordingly, with front and rear access for the separate air-flow paths. Power connections are M10 bar terminals accepting up to 6 × 40 mm² cable per phase, entry from top or bottom — sized for the 65 A line current at 3.3 kV. Operating position is vertical ±10°, and the enclosure is grey RAL 7032. Vibration resistance is 4.9 m/s² over 10...50 Hz — suitable for floor mounting near rotating machinery. ## Control I/O and auxiliary supplies Six discrete inputs standard (expandable to 10), four software-configurable analogue inputs (0...20 mA / 4...20 mA, 250 Ω impedance), and one analogue output of the same type — enough for basic speed reference, feedback, and status without an external I/O rack. Control power requires a separate 220 V AC, 3 kVA supply; the cooling fans need 380 V AC. An optional 220 V AC/DC control supply is available — important to spec the auxiliary transformer bank before commissioning. The drive includes an integrated EMC filter and carries CE marking to EN/IEC 61800-3 (emission and immunity for variable-speed drives). Compliance documentation covers CE marking and the full suite of EN/IEC 61800 standards for adjustable-speed power drive systems.","metaTitle":"Schneider Electric ATV1200A7506666 AC Drive, 627 kW, 750 kVA","metaDescription":"Schneider Electric ATV1200A7506666 Altivar 1200 medium-voltage drive, 627 kW motor power, 750 kVA apparent power, 36-pulse input. CE marked, active production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"1400 mm (standard efficiency) 1500 mm (high efficiency)","Width":"3360 mm (high efficiency) 3060 mm (standard efficiency)","title":"ATV1200A7506666","Height":"2520 mm standard efficiency 2670 mm high efficiency","Supply":"External supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)","Marking":"CE","Isolation":"Electrical between power and control","Standards":"EN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1","EMC filter":"Integrated","Input type":"36 pulse diode rectifier bridge","Noise level":"80 dB","Speed range":"20...100","description":"medium voltage variable speed drive ATV1200 - 6.6 kV - 750 kVA","Line current":"65 A","Apparent power":"750 kVA","Assembly style":"In floor-standing enclosure with separate air flows","Motor power kW":"627 kW","Output voltage":"<= power supply voltage","Protection type":"Ground fault protection: drive","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to EN/IEC 61800-5-1","Range of product":"Altivar 1200","Device short name":"ATV1200","Relative humidity":"0...90 % 0...95 % optional","Operating altitude":"1000...2000 m with current derating 0.6 % per 100 m","Operating position":"Vertical +/- 10 degree","Overload withstand":"1.2 In, standard overload, 60 s 1.5 In, standard overload, 3 s 1.5 In, high overload, 60 s 1.85 In, high overload, 3 s","Analogue input type":"software-configurable current: 0...20 mA/4...20 mA, 24 V max, impedance: 250 Ohm","Colour of enclosure":"Grey (RAL 7032)","Dielectric strength":"20 kV AC between earth and power terminals","Product Composition":"2 x plinth Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface 18 x power cells","Product destination":"Asynchronous motors","Analogue output type":"software-configurable current: 0...20 mA/4...20 mA DC, impedance: 250 Ohm","Overvoltage category":"II conforming to EN/IEC 61800-5-1","Prospective line Isc":"31.5 kA for 150 ms","Vibration resistance":"4.9 m/s² (f= 10...50 Hz)","Analogue input number":"4","Discrete input number":"6 10 (optional)","Electrical connection":"Bar - screw type M10, clamping capacity: 6 x 40 mm² (L1/R, L2/S, L3/T) entry from the bottom or from the top","Supply voltage limits":"2970...3630 V","Volume of cooling air":"13200 m3/h (standard efficiency) 19800 m3/h (high efficiency)","Analogue output number":"2 4 (optional)","Discrete output number":"10 14 (optional)","IP degree of protection":"IP31 IP42 IP41","Network number of phases":"3 phases","Continuous output current":"65 A (standard overload) 52 A (high overload)","Maximum transient current":"79 A for 60 s","Product or component type":"Medium voltage variable speed drive","[Us] rated supply voltage":"6.6 kV +/- 10 %","Communication port protocol":"Human machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9","Nominal switching frequency":"600 Hz","Product specific application":"Fan, pump, compressor, conveyor","Speed drive output frequency":"0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback","[Uc] control circuit voltage":"220 V","Synchronous motor control profile":"Voltage/frequency ratio (V/f) Closed-loop control with encoder","Asynchronous motor control profile":"Closed-loop control with encoder Vector control with sensor, optional Voltage/frequency ratio (V/f) Sensorless flux vector control","Acceleration and deceleration ramps":"Linear from 0...3200 s","Ambient air temperature for storage":"-10...60 °C","Ambient air temperature for operation":"0...40 °C 40...50 °C (with current derating of 2 % per °C)","Total Losses At 100 % Load Including Fan Power":"25 kW (standard efficiency) 22 kW (high efficiency)","Drive Efficiency With Transformer (Including Fan Power)":"96 % (standard efficiency) 96.5 % (high efficiency)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/vn/en/product/download-pdf/ATV1200A7506666?filename=Schneider+Electric_Altivar-1200_ATV1200A7506666.pdf', 'path_name': '5512dcf0c26dd856bec60674683942c9.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/5512dcf0c26dd856bec60674683942c9.pdf', 'status': 1}","sourceUrl":"https://www.se.com/vn/en/product/ATV1200A7506666/medium-voltage-variable-speed-drive-atv1200-6-6-kv-750-kva/"},"ai":{"faq":[{"question":"What asynchronous motor power can the ATV1200A7506666 drive?","answer":"The drive is rated for 627 kW motor power at 750 kVA apparent power, with a supply voltage range of 2970...3630 V and a 36-pulse diode rectifier input."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV1200A7506666","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV1200A7506666 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}