{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV1200A7904242","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV1200A7904242","canonicalUrl":"https://aoctrl.com/schneider/ATV1200A7904242","factsUrl":"https://aoctrl.com/api/mcp/products/ATV1200A7904242","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 1200 ATV1200A7904242 medium-voltage AC drive, 660 kW motor power, 790 kVA apparent power, 2970-3630 V supply, 24-pulse diode rectifier, floor-standing enclosure.","salesMarkdown":"The ATV1200A7904242 is a medium-voltage drive rated for 660 kW motor power and 790 kVA apparent power, fed from a 2970–3630 V supply. That voltage class puts it squarely on medium-voltage distribution, not a 480 V bus — the input is a 24-pulse diode rectifier bridge, which keeps line harmonics low enough to skip a separate filter in many installations. The drive handles both synchronous and asynchronous motors, and the output voltage tracks the supply voltage (no step-up). Standard overload is 1.2× In for 60 s or 1.5× In for 3 s; a high-overload profile offers 1.5× In for 60 s and 1.85× In for 3 s — choose the profile that matches your load cycle. ## Physical footprint and cooling – plan the room before the drive arrives This is a floor-standing enclosure, not a cabinet module. Standard-efficiency dimensions: 2520 mm high × 3060 mm wide × 1400 mm deep. High-efficiency variant adds height (2670 mm) and depth (1500 mm) and width (3660 mm). The enclosure colour is grey RAL 7032. Forced-convection cooling with separate air flows for power and control. Standard-efficiency version moves 13,200 m³/h of air; high-efficiency moves 19,800 m³/h. Noise level is 80 dB — ear protection zones around the drive are expected. The drive comes as a pre-assembled system: two plinths, phase-shifting transformer, medium-voltage arrestors, cooling fans, HMI, and 12 power cells. Power connections are bar-type M10 screw terminals accepting up to 6 × 40 mm² per phase, entry from top or bottom. ## Standards, isolation, and environmental limits CE marked. Designed to EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. Electrical isolation between power and control circuits. Dielectric strength tested at 20 kV AC between earth and power terminals. Pollution degree 2 per EN/IEC 61800-5-1, overvoltage category II. Operating altitude 1000–2000 m with 0.6 % current derating per 100 m above 1000 m. Relative humidity 0–90 % (0–95 % optional). Operating position vertical ±10°. Prospective line short-circuit withstand is 31.5 kA for 150 ms — the drive can ride through a fault on the incoming line for that duration without self-destruction. ## Sourcing – current production, quoted to order Sourced through independent distribution channels. Genuine is genuine — same part, different passport; warranty terms follow the region of origin.","metaTitle":"Schneider ATV1200A7904242 AC Drive, 660 kW, 790 kVA","metaDescription":"Schneider Electric ATV1200A7904242 medium-voltage drive, 660 kW motor power, 790 kVA, 24-pulse rectifier, CE marked. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"1400 mm (standard efficiency) 1500 mm (high efficiency)","Width":"3060 mm (standard efficiency) 3660 mm (high efficiency)","title":"ATV1200A7904242","Height":"2520 mm standard efficiency 2670 mm high efficiency","Supply":"External supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)","Marking":"CE","Isolation":"Electrical between power and control","Standards":"EN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1","EMC filter":"Integrated","Input type":"24 pulse diode rectifier bridge","Noise level":"80 dB","Speed range":"20...100","description":"medium voltage variable speed drive ATV1200 - 4.16 kV - 790 kVA","Line current":"150 A","Apparent power":"790 kVA","Assembly style":"In floor-standing enclosure with separate air flows","Motor power kW":"660 kW","Output voltage":"<= power supply voltage","Protection type":"Ground fault protection: drive","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to EN/IEC 61800-5-1","Range of product":"Altivar 1200","Device short name":"ATV1200","Relative humidity":"0...90 % 0...95 % optional","Operating altitude":"1000...2000 m with current derating 0.6 % per 100 m","Operating position":"Vertical +/- 10 degree","Overload withstand":"1.2 In, standard overload, 60 s 1.5 In, standard overload, 3 s 1.5 In, high overload, 60 s 1.85 In, high overload, 3 s","Analogue input type":"software-configurable current: 0...20 mA/4...20 mA, 24 V max, impedance: 250 Ohm","Colour of enclosure":"Grey (RAL 7032)","Dielectric strength":"20 kV AC between earth and power terminals","Product Composition":"2 x plinth Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface 12 x power cells","Product destination":"Synchronous motors Asynchronous motors","Analogue output type":"software-configurable current: 0...20 mA/4...20 mA DC, impedance: 250 Ohm","Overvoltage category":"II conforming to EN/IEC 61800-5-1","Prospective line Isc":"31.5 kA for 150 ms","Vibration resistance":"4.9 m/s² (f= 10...50 Hz)","Analogue input number":"4","Discrete input number":"6 10 (optional)","Electrical connection":"Bar - screw type M10, clamping capacity: 6 x 40 mm² (L1/R, L2/S, L3/T) entry from the bottom or from the top","Supply voltage limits":"2970...3630 V","Volume of cooling air":"13200 m3/h (standard efficiency) 19800 m3/h (high efficiency)","Analogue output number":"2 4 (optional)","Discrete output number":"10 14 (optional)","IP degree of protection":"IP41 IP31 IP42","Network number of phases":"3 phases","Continuous output current":"109 A (standard overload) 87 A (high overload)","Maximum transient current":"131 A for 60 s","Product or component type":"Medium voltage variable speed drive","[Us] rated supply voltage":"4.16 kV +/- 10 %","Communication port protocol":"Human machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9","Nominal switching frequency":"600 Hz","Product specific application":"Fan, pump, compressor, conveyor","Speed drive output frequency":"0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback","[Uc] control circuit voltage":"220 V","Synchronous motor control profile":"Closed-loop control with encoder Voltage/frequency ratio (V/f)","Asynchronous motor control profile":"Sensorless flux vector control Vector control with sensor, optional Closed-loop control with encoder Voltage/frequency ratio (V/f)","Acceleration and deceleration ramps":"Linear from 0...3200 s","Ambient air temperature for storage":"-10...60 °C","Ambient air temperature for operation":"0...40 °C 40...50 °C (with current derating of 2 % per °C)","Total Losses At 100 % Load Including Fan Power":"26 kW (standard efficiency) 23 kW (high efficiency)","Drive Efficiency With Transformer (Including Fan Power)":"96 % (standard efficiency) 96.5 % (high efficiency)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/vn/en/product/download-pdf/ATV1200A7904242?filename=Schneider+Electric_Altivar-1200_ATV1200A7904242.pdf', 'path_name': 'c257101ecc4fea6e37f8e060d32ebab6.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/c257101ecc4fea6e37f8e060d32ebab6.pdf', 'status': 1}","sourceUrl":"https://www.se.com/vn/en/product/ATV1200A7904242/medium-voltage-variable-speed-drive-atv1200-4-16-kv-790-kva/"},"ai":{"faq":[{"question":"How do I get current pricing and availability for ATV1200A7904242?","answer":"Submit an RFQ against your BOM quantity. No stock-holding claim is made here."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV1200A7904242","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV1200A7904242 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}