{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV1200A82506666","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV1200A82506666","canonicalUrl":"https://aoctrl.com/schneider/ATV1200A82506666","factsUrl":"https://aoctrl.com/api/mcp/products/ATV1200A82506666","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 1200 ATV1200A82506666 medium-voltage AC drive, 6897 kW motor power, 8250 kVA apparent power, 36-pulse diode rectifier, 2970…3630 V supply, floor-standing enclosure.","salesMarkdown":"## 6897 kW drive, floor-standing — what it means on the line The ATV1200A82506666 is a medium-voltage drive from the Altivar 1200 family, rated for 6897 kW motor power and 8250 kVA apparent power. That puts it squarely in the large-motor class — think mainline conveyors, crushers, large pumps or compressors in mining, cement, or oil-and-gas installations. Supply voltage range is 2970…3630 V, fed through a 36-pulse diode rectifier bridge. The 36-pulse topology cancels the 5th, 7th, 11th, and 13th harmonics at the input, which means you can often skip a dedicated harmonic filter at the point of common coupling — that saves panel space and transformer derating. ## Physical footprint and installation constraints This is a floor-standing enclosure, not a wall-mount. Dimensions are 3040 mm high, 9770 mm wide, and 1700 mm deep — so you need a dedicated drive room with a reinforced floor and a crane or forklift path for positioning. The enclosure has separate air flows for power and control sections, which keeps the electronics cooler and reduces dust ingress. Cooling is forced convection pulling 100,000 m³/h of air — that's substantial. The room's HVAC and louvers need to handle that airflow without recirculating hot exhaust. Operating altitude derating starts at 1000 m: 0.6 % current reduction per 100 m above that. ## Overload duty and auxiliary supply architecture The drive supports two overload profiles. Standard overload: 1.2× In for 60 s, 1.5× In for 3 s. High overload: 1.5× In for 60 s, 1.85× In for 3 s. Pick the profile that matches your load cycle — high overload covers crusher start-ups or extruder breakaway torque without oversizing the drive frame. Control electronics need an external 220 V AC supply rated at 3 kVA. The cooling fans run on a separate 380 V AC supply (also external). There's an optional 220 V AC/DC control supply. This split architecture means the control section stays live even if the main power is off — useful for pre-charge sequencing and diagnostics before the main contactor closes. Compliance is solid: CE marked, designed to EN/IEC 61800-3 (EMC), EN/IEC 61800-4 (adjustable speed drives), and EN/IEC 61800-5-1 (electrical safety). Pollution degree 2 per the same safety standard, overvoltage category II. The integrated EMC filter means you don't need an external input filter for most installations.","metaTitle":"Schneider ATV1200A82506666 AC Drive, 6897 kW, 8250 kVA","metaDescription":"Schneider Electric ATV1200A82506666 medium-voltage VFD, 6897 kW motor power, 8250 kVA apparent power, 36-pulse input, CE marked.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"1700 mm (standard efficiency)","Width":"9770 mm (standard efficiency)","title":"ATV1200A82506666","Height":"3040 mm standard efficiency","Supply":"External supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)","Marking":"CE","Isolation":"Electrical between power and control","Standards":"EN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1","EMC filter":"Integrated","Input type":"36 pulse diode rectifier bridge","Noise level":"80 dB","Speed range":"20...100","description":"medium voltage variable speed drive ATV1200 - 6.6 kV - 8250 kVA","Line current":"720 A","Apparent power":"8250 kVA","Assembly style":"In floor-standing enclosure with separate air flows","Motor power kW":"6897 kW","Output voltage":"<= power supply voltage","Protection type":"Ground fault protection: drive","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to EN/IEC 61800-5-1","Range of product":"Altivar 1200","Device short name":"ATV1200","Relative humidity":"0...90 % 0...95 % optional","Operating altitude":"1000...2000 m with current derating 0.6 % per 100 m","Operating position":"Vertical +/- 10 degree","Overload withstand":"1.2 In, standard overload, 60 s 1.5 In, standard overload, 3 s 1.5 In, high overload, 60 s 1.85 In, high overload, 3 s","Analogue input type":"software-configurable current: 0...20 mA/4...20 mA, 24 V max, impedance: 250 Ohm","Colour of enclosure":"Grey (RAL 7032)","Dielectric strength":"20 kV AC between earth and power terminals","Product Composition":"2 x plinth Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface 18 x power cells","Product destination":"Asynchronous motors","Analogue output type":"software-configurable current: 0...20 mA/4...20 mA DC, impedance: 250 Ohm","Overvoltage category":"II conforming to EN/IEC 61800-5-1","Prospective line Isc":"31.5 kA for 150 ms","Vibration resistance":"4.9 m/s² (f= 10...50 Hz)","Analogue input number":"4","Discrete input number":"6 10 (optional)","Electrical connection":"Bar - screw type M10, clamping capacity: 6 x 40 mm² (L1/R, L2/S, L3/T) entry from the bottom or from the top","Supply voltage limits":"2970...3630 V","Volume of cooling air":"100000 m3/h (standard efficiency)","Analogue output number":"2 4 (optional)","Discrete output number":"10 14 (optional)","IP degree of protection":"IP41 IP31 IP42","Network number of phases":"3 phases","Continuous output current":"720 A (standard overload) 576 A (high overload)","Maximum transient current":"864 A for 60 s","Product or component type":"Medium voltage variable speed drive","[Us] rated supply voltage":"6.6 kV +/- 10 %","Communication port protocol":"Human machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9","Nominal switching frequency":"600 Hz","Product specific application":"Fan, pump, compressor, conveyor","Speed drive output frequency":"0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback","[Uc] control circuit voltage":"220 V","Synchronous motor control profile":"Voltage/frequency ratio (V/f) Closed-loop control with encoder","Asynchronous motor control profile":"Vector control with sensor, optional Sensorless flux vector control Voltage/frequency ratio (V/f) Closed-loop control with encoder","Acceleration and deceleration ramps":"Linear from 0...3200 s","Ambient air temperature for storage":"-10...60 °C","Ambient air temperature for operation":"0...40 °C 40...50 °C (with current derating of 2 % per °C)","Total Losses At 100 % Load Including Fan Power":"221 kW (standard efficiency)","Drive Efficiency With Transformer (Including Fan Power)":"96 % (standard efficiency)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/vn/en/product/download-pdf/ATV1200A82506666?filename=Schneider+Electric_Altivar-1200_ATV1200A82506666.pdf', 'path_name': 'a1ad2b7f01a625878b539a501ad214fe.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/a1ad2b7f01a625878b539a501ad214fe.pdf', 'status': 1}","sourceUrl":"https://www.se.com/vn/en/product/ATV1200A82506666/medium-voltage-variable-speed-drive-atv1200-6-6-kv-8250-kva/"},"ai":{"faq":[{"question":"Who supplies ATV1200A82506666 and how is it quoted for volume purchases?","answer":"We source this drive through independent industrial distribution. It is quoted to order against your BOM; availability and volume pricing are confirmed at the time of RFQ. Because this is a medium-voltage drive with significant lead times, we recommend submitting a formal request with your target quantity and delivery window."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV1200A82506666","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV1200A82506666 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}