{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV1200A85001010","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV1200A85001010","canonicalUrl":"https://aoctrl.com/schneider/ATV1200A85001010","factsUrl":"https://aoctrl.com/api/mcp/products/ATV1200A85001010","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 1200 ATV1200A85001010 AC Drive (VFD) 480V, 7106 kW motor power, 8500 kVA apparent power, 48-pulse input, floor-standing enclosure.","salesMarkdown":"## What this VFD is and what it drives The Schneider Electric ATV1200A85001010 is a medium-voltage AC drive from the Altivar 1200 family, designed for large asynchronous motors up to 7106 kW. It delivers 8500 kVA apparent power from a 2970...3630 V supply, using a 48-pulse diode rectifier bridge input topology that keeps line-side harmonics low enough to often skip an external filter. ## Sizing the overload and fault handling The drive handles 1.2× In for 60 s under standard overload, and 1.5× In for 3 s; for high-overload profiles it sustains 1.5× In for 60 s and 1.85× In for 3 s — match the duty cycle to your load profile before freezing the BOM. Prospective line short-circuit current is rated at 31.5 kA for 150 ms, and the drive includes ground-fault protection on the output side. Dielectric strength between earth and power terminals is 28 kV AC — this is a medium-voltage drive, not a 480 V unit; the supply voltage limits (2970...3630 V) confirm the class. ## Physical footprint and installation constraints The drive ships in a floor-standing enclosure measuring 1700 mm deep, 9370 mm wide, and 3040 mm high — this is a multi-cabinet lineup, not a wall-mount unit. Plan for a dedicated electrical room with overhead bus or cable trench access. Cooling is forced convection requiring 110000 m³/h of air volume — the room HVAC must handle this rejection, and the separate air-flow paths keep power-cell heat from recirculating into the control section. Noise level is 80 dB — hearing protection zones apply near the enclosure during operation. Operating altitude derating starts at 1000 m: 0.6 % per 100 m above that. The drive must be mounted vertical ±10° and the ambient relative humidity kept between 0...90 % (0...95 % with optional treatment). ## Control supply and I/O architecture The control section needs an external 220 V AC supply at 3 kVA (or optional 220 V AC/DC); the cooling fans run on a separate 380 V AC supply. Electrical isolation between power and control circuits is maintained. Standard I/O includes 4 software-configurable analogue inputs (0...20 mA / 4...20 mA, 250 Ω impedance), 1 analogue output of the same type, 6 discrete inputs (expandable to 10), and a built-in EMC filter. Main power connection uses M10 screw-type bars accepting up to 6 × 40 mm² cable per phase, entry from top or bottom. ## Standards compliance and lifecycle status The drive carries CE marking and complies with EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. Lifecycle stage is current production — this is an active catalogue item, not a phase-out or legacy part. The ATV1200 series remains in Schneider's standard portfolio for medium-voltage drives.","metaTitle":"Schneider Electric ATV1200A85001010 AC Drive, 7106 kW","metaDescription":"Schneider Electric ATV1200A85001010 Altivar 1200 AC Drive (VFD) 480V. 7106 kW motor power, 8500 kVA apparent power, 48-pulse input. Current production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"1700 mm (standard efficiency)","Width":"9370 mm (standard efficiency)","title":"ATV1200A85001010","Height":"3040 mm standard efficiency","Supply":"External supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)","Marking":"CE","Isolation":"Electrical between power and control","Standards":"EN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1","EMC filter":"Integrated","Input type":"48 pulse diode rectifier bridge","Noise level":"80 dB","Speed range":"20...100","description":"medium voltage variable speed drive ATV1200 - 10 kV - 8500 kVA","Line current":"490 A","Apparent power":"8500 kVA","Assembly style":"In floor-standing enclosure with separate air flows","Motor power kW":"7106 kW","Output voltage":"<= power supply voltage","Protection type":"Ground fault protection: drive","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to EN/IEC 61800-5-1","Range of product":"Altivar 1200","Device short name":"ATV1200","Relative humidity":"0...90 % 0...95 % optional","Operating altitude":"1000...2000 m with current derating 0.6 % per 100 m","Operating position":"Vertical +/- 10 degree","Overload withstand":"1.2 In, standard overload, 60 s 1.5 In, standard overload, 3 s 1.5 In, high overload, 60 s 1.85 In, high overload, 3 s","Analogue input type":"software-configurable current: 0...20 mA/4...20 mA, 24 V max, impedance: 250 Ohm","Colour of enclosure":"Grey (RAL 7032)","Dielectric strength":"28 kV AC between earth and power terminals","Product Composition":"2 x plinth Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface 24 x power cells","Product destination":"Asynchronous motors","Analogue output type":"software-configurable current: 0...20 mA/4...20 mA DC, impedance: 250 Ohm","Overvoltage category":"II conforming to EN/IEC 61800-5-1","Prospective line Isc":"31.5 kA for 150 ms","Vibration resistance":"4.9 m/s² (f= 10...50 Hz)","Analogue input number":"4","Discrete input number":"6 10 (optional)","Electrical connection":"Bar - screw type M10, clamping capacity: 6 x 40 mm² (L1/R, L2/S, L3/T) entry from the bottom or from the top","Supply voltage limits":"2970...3630 V","Volume of cooling air":"110000 m3/h (standard efficiency)","Analogue output number":"2 4 (optional)","Discrete output number":"10 14 (optional)","IP degree of protection":"IP42 IP31 IP41","Network number of phases":"3 phases","Continuous output current":"490 A (standard overload) 392 A (high overload)","Maximum transient current":"588 A for 60 s","Product or component type":"Medium voltage variable speed drive","[Us] rated supply voltage":"10 kV +/- 10 %","Communication port protocol":"Human machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9","Nominal switching frequency":"600 Hz","Product specific application":"Fan, pump, compressor, conveyor","Speed drive output frequency":"0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback","[Uc] control circuit voltage":"220 V","Synchronous motor control profile":"Voltage/frequency ratio (V/f) Closed-loop control with encoder","Asynchronous motor control profile":"Vector control with sensor, optional Closed-loop control with encoder Sensorless flux vector control Voltage/frequency ratio (V/f)","Acceleration and deceleration ramps":"Linear from 0...3200 s","Ambient air temperature for storage":"-10...60 °C","Ambient air temperature for operation":"0...40 °C 40...50 °C (with current derating of 2 % per °C)","Total Losses At 100 % Load Including Fan Power":"227 kW (standard efficiency)","Drive Efficiency With Transformer (Including Fan Power)":"96 % (standard efficiency)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/vn/en/product/download-pdf/ATV1200A85001010?filename=Schneider+Electric_Altivar-1200_ATV1200A85001010.pdf', 'path_name': '6a9422192c92ef6a14e953bff8b2de48.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/6a9422192c92ef6a14e953bff8b2de48.pdf', 'status': 1}","sourceUrl":"https://www.se.com/vn/en/product/ATV1200A85001010/medium-voltage-variable-speed-drive-atv1200-10-kv-8500-kva/"},"ai":{"faq":[{"question":"What compliance documentation does the ATV1200A85001010 carry?","answer":"CE marking is standard. The drive complies with EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1."},{"question":"Where can I buy the ATV1200A85001010 and how is it quoted?","answer":"Sourced through independent distribution channels. No stock-holding claim; this is a build-to-order medium-voltage drive."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV1200A85001010","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV1200A85001010 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}