{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV1200A95301010","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV1200A95301010","canonicalUrl":"https://aoctrl.com/schneider/ATV1200A95301010","factsUrl":"https://aoctrl.com/api/mcp/products/ATV1200A95301010","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 1200 ATV1200A95301010 medium-voltage AC drive, 7967 kW motor power, 9530 kVA apparent power, 48-pulse diode rectifier, floor-standing enclosure.","salesMarkdown":"## Medium-voltage drive for large asynchronous motors The ATV1200A95301010 is a medium-voltage drive in the Altivar 1200 series, rated for 7967 kW motor power at 9530 kVA apparent power — sized for large pumps, conveyors, fans, and compressors in mining, mineral processing, and heavy industrial plants. Input voltage range is 2970 to 3630 V AC, with a 48-pulse diode rectifier bridge that keeps line harmonics low enough to avoid external filters in most installations. ## Floor-standing footprint and site prep This drive ships in a floor-standing enclosure with separate air flows for the power section and control compartment — plan for a footprint of 14.48 m wide by 1.6 m deep, 3.04 m tall, with 140,000 m³/h of cooling air volume. Operating position is vertical ±10 degrees; altitude derating starts at 1000 m at 0.6% per 100 m. Ambient relative humidity 0-90% (95% optional). Noise level is 80 dB — hearing protection zone likely required. ## Overload profile and protection Standard overload rating is 1.2× In for 60 seconds and 1.5× In for 3 seconds; high overload goes to 1.5× In for 60 s and 1.85× In for 3 s. Ground fault protection is integrated into the drive. Dielectric strength is 28 kV AC between earth and power terminals. Prospective short-circuit current withstand is 31.5 kA for 150 ms — coordination with upstream protection is critical. ## Control wiring and I/O complement Control supply requires an external 220 V AC source at 3 kVA (optional 220 V AC/DC). The drive includes 4 software-configurable analogue inputs (0-20 mA / 4-20 mA, 250 Ω impedance), 1 analogue output (same range), and 6 discrete inputs (10 optional). Electrical isolation between power and control circuits is maintained throughout. Pollution degree 2 per EN/IEC 61800-5-1, overvoltage category II. Marked CE, compliant with EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. Integrated EMC filter is standard. Product composition includes 2 plinths, a phase-shifting transformer, medium-voltage arrestors, cooling fans, a human-machine interface, and 24 power cells — each field-replaceable.","metaTitle":"Schneider ATV1200A95301010 AC Drive (VFD) 480V, 7967 kW","metaDescription":"Schneider Electric ATV1200A95301010 medium-voltage drive, 7967 kW motor power, 48-pulse rectifier, floor-standing. Current production, quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"1600 mm (standard efficiency)","Width":"14480 mm (standard efficiency)","title":"ATV1200A95301010","Height":"3040 mm standard efficiency","Supply":"External supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)","Marking":"CE","Isolation":"Electrical between power and control","Standards":"EN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1","EMC filter":"Integrated","Input type":"48 pulse diode rectifier bridge","Noise level":"80 dB","Speed range":"20...100","description":"medium voltage variable speed drive ATV1200 - 10 kV - 9530 kVA","Line current":"550 A","Apparent power":"9530 kVA","Assembly style":"In floor-standing enclosure with separate air flows","Motor power kW":"7967 kW","Output voltage":"<= power supply voltage","Protection type":"Ground fault protection: drive","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to EN/IEC 61800-5-1","Range of product":"Altivar 1200","Device short name":"ATV1200","Relative humidity":"0...90 % 0...95 % optional","Operating altitude":"1000...2000 m with current derating 0.6 % per 100 m","Operating position":"Vertical +/- 10 degree","Overload withstand":"1.2 In, standard overload, 60 s 1.5 In, standard overload, 3 s 1.5 In, high overload, 60 s 1.85 In, high overload, 3 s","Analogue input type":"software-configurable current: 0...20 mA/4...20 mA, 24 V max, impedance: 250 Ohm","Colour of enclosure":"Grey (RAL 7032)","Dielectric strength":"28 kV AC between earth and power terminals","Product Composition":"2 x plinth Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface 24 x power cells","Product destination":"Asynchronous motors","Analogue output type":"software-configurable current: 0...20 mA/4...20 mA DC, impedance: 250 Ohm","Overvoltage category":"II conforming to EN/IEC 61800-5-1","Prospective line Isc":"31.5 kA for 150 ms","Vibration resistance":"4.9 m/s² (f= 10...50 Hz)","Analogue input number":"4","Discrete input number":"6 10 (optional)","Electrical connection":"Bar - screw type M10, clamping capacity: 6 x 40 mm² (L1/R, L2/S, L3/T) entry from the bottom or from the top","Supply voltage limits":"2970...3630 V","Volume of cooling air":"140000 m3/h (standard efficiency)","Analogue output number":"2 4 (optional)","Discrete output number":"10 14 (optional)","IP degree of protection":"IP42 IP41 IP31","Network number of phases":"3 phases","Continuous output current":"550 A (standard overload) 440 A (high overload)","Maximum transient current":"660 A for 60 s","Product or component type":"Medium voltage variable speed drive","[Us] rated supply voltage":"10 kV +/- 10 %","Communication port protocol":"Human machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9","Nominal switching frequency":"600 Hz","Product specific application":"Fan, pump, compressor, conveyor","Speed drive output frequency":"0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback","[Uc] control circuit voltage":"220 V","Synchronous motor control profile":"Voltage/frequency ratio (V/f) Closed-loop control with encoder","Asynchronous motor control profile":"Closed-loop control with encoder Vector control with sensor, optional Voltage/frequency ratio (V/f) Sensorless flux vector control","Acceleration and deceleration ramps":"Linear from 0...3200 s","Ambient air temperature for storage":"-10...60 °C","Ambient air temperature for operation":"0...40 °C 40...50 °C (with current derating of 2 % per °C)","Total Losses At 100 % Load Including Fan Power":"319 kW (standard efficiency)","Drive Efficiency With Transformer (Including Fan Power)":"96 % (standard efficiency)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/vn/en/product/download-pdf/ATV1200A95301010?filename=Schneider+Electric_Altivar-1200_ATV1200A95301010.pdf', 'path_name': 'a6363b46ab227f2bf7803b2b0ad9a26b.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/a6363b46ab227f2bf7803b2b0ad9a26b.pdf', 'status': 1}","sourceUrl":"https://www.se.com/vn/en/product/ATV1200A95301010/medium-voltage-variable-speed-drive-atv1200-10-kv-9530-kva/"},"ai":{"faq":[{"question":"What is the ATV1200A95301010 used for?","answer":"It is a medium-voltage AC drive for asynchronous motors up to 7967 kW, typically driving large pumps, fans, compressors, and conveyors in mining, mineral processing, and heavy industry."},{"question":"What compliance documentation does Schneider provide for this drive?","answer":"The drive carries CE marking and complies with EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. An integrated EMC filter is standard."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV1200A95301010","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV1200A95301010 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}