{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV212H075M3X","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV212H075M3X","canonicalUrl":"https://aoctrl.com/schneider/ATV212H075M3X","factsUrl":"https://aoctrl.com/api/mcp/products/ATV212H075M3X","rawCanonicalId":null},"summary":{"shortDescription":"variable speed drive ATV212 - 0.75kW - 1hp - 240V - 3ph - wo EMC - IP21|variable speed drive ATV212 - 0.75kW - 1hp - 240V - 3ph - wo EMC - IP21","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"5.9 in (150 mm)","Phase":"3 phase","Width":"4.2 in (107 mm)","Height":"5.6 in (143 mm)","Marking":"CE","Air flow":"5811.9 Gal/hr(US) (22 m3/h)","Category":"US1CP4D22155","Standards":"IEC 61800-3 IEC 61800-3 environments 1 category C1 IEC 61800-5-1 IEC 61800-3 environments 1 category C3 IEC 61800-3 environments 2 category C1 IEC 61800-3 IEC 61800-3 environments 2 category C1 IEC 61800-5-1 IEC 61800-3 environments 1 category C2 IEC 61800-3 environments 1 category C1 IEC 61800-3 environments 2 category C3 UL Type 1 IEC 61800-3 environments 2 category C2 IEC 61800-3 environments 1 category C2 IEC 61800-3 environments 2 category C2 IEC 61800-3 environments 1 category C3 IEC 61800-3 environments 2 category C3","EMC filter":"Without EMC filter","Data format":"8 bits, 1 stop, odd even or no configurable parity","Noise level":"51 dB 86/188/EEC","Option card":"Communication card LonWorks","Speed range":"1...10","Line current":"2.7 A 240 V 3.3 A 200 V","Apparent power":"1.8 kVA 240 V","Assembly style":"With heat sink","Connector Type":"1 RJ45 1 open style","Motor power kW":"0.75 kW","Output voltage":"= 1 mOhm 500 V DC for 1 minute","Speed accuracy":"+/- 10 % of nominal slip 0.2 Tn to Tn","Protection type":"Overheating protection drive Thermal power stage drive Short-circuit between motor phases drive Input phase breaks drive Overcurrent between output phases and earth drive Overvoltages on the DC bus drive Break on the control circuit drive Against exceeding limit speed drive Line supply overvoltage and undervoltage drive Line supply undervoltage drive Against input phase loss drive Thermal protection motor Motor phase break motor With PTC probes motor","Regulation loop":"Adjustable PI regulator","Torque accuracy":"+/- 15 %","lifecycle_stage":"mature","Local signalling":"1 LED (red) for DC bus energized","Pollution degree":"2 IEC 61800-5-1","Range of Product":"Altivar 212","Shock resistance":"15 gn 11 ms IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV212","Network Frequency":"47.5...63 Hz","Relative humidity":"5...95 % without condensation IEC 60068-2-3 5...95 % without dripping water IEC 60068-2-3","Transmission Rate":"9600 bps or 19200 bps","Motor starter type":"Variable speed drive","Operating altitude":"3280.84...9842.52 ft (1000...3000 m) limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m <= 3280.84 ft (1000 m) without derating","Operating position":"Vertical +/- 10 degree","Physical interface":"2-wire RS 485","Transmission frame":"RTU","Analogue input type":"VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits VIB configurable PTC probe 0...6 probes 1500 Ohm VIA switch-configurable current 0...20 mA 250 Ohm 10 bits","Number of addresses":"1...247","Product destination":"Asynchronous motors","Switching frequency":"6...16 kHz adjustable 12...16 kHz with derating factor","Frequency resolution":"Display unit 0.1 Hz Analog input 0.024/50 Hz","Prospective line Isc":"5 kA","Specific application":"HVAC","Transient overtorque":"120 % of nominal motor torque +/- 10 % 60 s","Type of polarization":"No impedance","Vibration resistance":"1.5 mm (f= 3...13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13...200 Hz) conforming to EN/IEC 60068-2-8","Analogue input number":"2","Braking to standstill":"By DC injection","Communication Service":"Read holding registers (03) 2 words maximum Write multiple registers (16) 2 words maximum Write single register (06) Time out setting from 0.1 to 100 s Monitoring inhibitable Read device identification (43)","Nbr. of units in pkg.":"1","Supply voltage limits":"170...264 V","Analogue output number":"1","Discrete output number":"2","Motor power range AC-3":"0.55...1 kW 200...240 V 3 phase","Power dissipation in W":"63 W","IP degree of protection":"IP21","Motor slip compensation":"Automatic whatever the load Adjustable Not available in voltage/frequency ratio motor control","Continuous output current":"4.6 A 230 V","Maximum transient current":"5.1 A 60 s","Product or Component Type":"Variable speed drive","[Us] rated supply voltage":"200...240 V - 15...10 %","Maximum Horse Power Rating":"1 hp","Communication Port Protocol":"LonWorks Modbus APOGEE FLN METASYS N2 BACnet","Nominal switching frequency":"12 kHz","Environmental characteristic":"Classes 3C1 conforming to IEC 60721-3-3 Classes 3S2 conforming to IEC 60721-3-3","Product Specific Application":"Pumps and fans in HVAC","Speed drive output frequency":"0.5...200 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11","Asynchronous motor control profile":"Voltage/frequency ratio, 2 points Voltage/frequency ratio - Energy Saving, quadratic U/f Voltage/frequency ratio, 5 points Flux vector control without sensor, standard Voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo)","Acceleration and deceleration ramps":"Linear adjustable separately from 0.01 to 3200 s Automatic based on the load","Ambient Air Temperature for Storage":"-13...158 °F (-25...70 °C)","Environment/IP degree of protection":"IP20 on upper part without blanking plate on cover IEC 61800-5-1 IP20 on upper part without blanking plate on cover IEC 60529 IP21 IEC 61800-5-1 IP21 IEC 60529 IP41 on upper part IEC 61800-5-1 IP41 on upper part IEC 60529","Ambient air temperature for operation":"14...104 °F (-10...40 °C) (without derating) 104...122 °F (40...50 °C) (with derating factor)","Variable speed drive application selection":"Building - HVAC compressor for scroll Building - HVAC fan Building - HVAC pump"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$402.59","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3e0bab7667d85d49a2e7ea0bd369e735.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/ATV212H075M3X/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV212H075M3X","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV212H075M3X when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}