{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV212HD11N4","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV212HD11N4","canonicalUrl":"https://aoctrl.com/schneider/ATV212HD11N4","factsUrl":"https://aoctrl.com/api/mcp/products/ATV212HD11N4","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 212 ATV212HD11N4 AC drive, 11 kW, 3-phase 380-480 V, IP20, integrated class C2 EMC filter, 6.7 x 7.09 x 9.1 in.","salesMarkdown":"## Altivar 212 drive for HVAC and pumping The ATV212HD11N4 is a 11 kW variable speed drive from the Altivar 212 range, designed for 3-phase 380-480 V supply. It delivers 17.1 kVA apparent power at 380 V and draws 21.1 A line current at 380 V or 16.8 A at 480 V. An integrated class C2 EMC filter is built in, covering conducted emissions for most European installations without an external filter. The drive complies with IEC 61800-3 environments 1 and 2 across categories C1, C2, and C3, and carries CE marking. ## Dimensions, mounting, and airflow The drive measures 6.7 in deep, 7.09 in wide, and 9.1 in high (170 x 180 x 232 mm). It mounts vertically within ±10°, with a heat sink on the rear for thermal dissipation. Forced airflow is rated at 147 m³/h (38834 gal/h US). Operating altitude is 1000 m without derating; above that, derate 1 % per 100 m up to 3000 m, with a 2000 m limit for corner-grounded distribution networks. Pollution degree 2 per IEC 61800-5-1 applies. ## Protection and control features The drive includes an adjustable PI regulator for closed-loop process control, with speed accuracy of ±10 % of nominal slip from 0.2 Tn to Tn and torque accuracy of ±15 %. Speed range is 1 to 10. Protection covers overheating, short-circuit between motor phases, overcurrent between output phases and earth, DC bus overvoltage, input phase loss, motor thermal protection, and PTC probe input. A red LED signals DC bus energized. Analog inputs are switch-configurable: VIA accepts 0-10 V DC or 0-20 mA (10-bit, 30 kΩ voltage, 250 Ω current); VIB accepts 0-10 V DC or PTC probe (0-6 probes, 1500 Ω). ## Communication and compliance The drive is equipped with a 2-wire RS-485 physical interface using RTU protocol at 9600 or 19200 bps, with an RJ45 connector. An optional LonWorks communication card is available.","metaTitle":"Schneider ATV212HD11N4 AC Drive, 11 kW, 3-phase, 480 V","metaDescription":"Schneider Electric ATV212HD11N4 Altivar 212 AC drive, 11 kW, 3-phase 380-480 V, IP20, with integrated class C2 EMC filter. Mature lifecycle, quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"6.7 in (170 mm)","Phase":"3 phase","Width":"7.09 in (180 mm)","title":"ATV212HD11N4","Height":"9.1 in (232 mm)","Marking":"CE","Air flow":"38834.0 Gal/hr(US) (147 m3/h)","Category":"US1CP4D22157","Standards":"IEC 61800-3 category C2 IEC 61800-3 environments 1 category C2 IEC 61800-3 category C3 IEC 61800-3 environments 1 category C3 IEC 61800-3 environments 2 category C3 UL Type 1 IEC 61800-3 environments 1 category C1 IEC 61800-3 environments 1 category C3 IEC 61800-3 environments 2 category C3 IEC 61800-3 environments 2 category C2 IEC 61800-3 IEC 61800-3 category C2 IEC 61800-3 environments 1 category C1 IEC 61800-5-1 EN 55011 class A group 1 IEC 61800-3 environments 2 category C2 EN 61800-3 category C3 IEC 61800-5-1 IEC 61800-3 environments 2 category C1 IEC 61800-3 IEC 61800-3 environments 1 category C2 IEC 61800-3 environments 2 category C1","EMC filter":"Class C2 EMC filter integrated","Data format":"8 bits, 1 stop, odd even or no configurable parity","Noise level":"51 dB 86/188/EEC","Option card":"Communication card LonWorks","Speed range":"1...10","description":"variable speed drive ATV212 - 11kW - 15hp - 480V - 3ph - EMC - IP21","Line current":"16.8 A 480 V 21.1 A 380 V","Functionality":"Mid","Apparent power":"17.1 kVA 380 V","Assembly style":"With heat sink","Connector Type":"1 open style 1 RJ45","Motor power kW":"11 kW","Output voltage":"= 1 mOhm 500 V DC for 1 minute","Speed accuracy":"+/- 10 % of nominal slip 0.2 Tn to Tn","Protection type":"Overheating protection drive Thermal power stage drive Short-circuit between motor phases drive Input phase breaks drive Overcurrent between output phases and earth drive Overvoltages on the DC bus drive Break on the control circuit drive Against exceeding limit speed drive Line supply overvoltage and undervoltage drive Line supply undervoltage drive Against input phase loss drive Thermal protection motor Motor phase break motor With PTC probes motor","Regulation loop":"Adjustable PI regulator","Torque accuracy":"+/- 15 %","lifecycle_stage":"mature","Local signalling":"1 LED (red) for DC bus energized","Pollution degree":"2 IEC 61800-5-1","Range of Product":"Altivar 212","Shock resistance":"15 gn 11 ms IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV212","Network Frequency":"47.5...63 Hz","Relative humidity":"5...95 % without condensation IEC 60068-2-3 5...95 % without dripping water IEC 60068-2-3","Transmission Rate":"9600 bps or 19200 bps","Motor starter type":"Variable speed drive","Operating altitude":"3280.84...9842.52 ft (1000...3000 m) limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m <= 3280.84 ft (1000 m) without derating","Operating position":"Vertical +/- 10 degree","Physical interface":"2-wire RS 485","Transmission frame":"RTU","Analogue input type":"VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits VIB configurable PTC probe 0...6 probes 1500 Ohm VIA switch-configurable current 0...20 mA 250 Ohm 10 bits","Number of addresses":"1...247","Product destination":"Asynchronous motors","Switching frequency":"6...16 kHz adjustable 12...16 kHz with derating factor","Frequency resolution":"Display unit 0.1 Hz Analog input 0.024/50 Hz","Prospective line Isc":"22 kA","Specific application":"HVAC","Transient overtorque":"120 % of nominal motor torque +/- 10 % 60 s","Type of polarization":"No impedance","Vibration resistance":"1.5 mm (f= 3...13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13...200 Hz) conforming to EN/IEC 60068-2-8","Analogue input number":"2","Braking to standstill":"By DC injection","Communication Service":"Read holding registers (03) 2 words maximum Time out setting from 0.1 to 100 s Write single register (06) Monitoring inhibitable Write multiple registers (16) 2 words maximum Read device identification (43)","Nbr. of units in pkg.":"1","Supply voltage limits":"323...528 V","Analogue output number":"1","Discrete output number":"2","Motor power range AC-3":"7...11 kW 380...440 V 3 phase 7...11 kW 480...500 V 3 phase","Power dissipation in W":"430 W","IP degree of protection":"IP21","Motor slip compensation":"Not available in voltage/frequency ratio motor control Adjustable Automatic whatever the load","Continuous output current":"22.5 A 380 V 22.5 A 460 V","Maximum transient current":"24.8 A 60 s","Product or Component Type":"Variable speed drive","[Us] rated supply voltage":"380...480 V - 15...10 %","Maximum Horse Power Rating":"15 hp","Communication Port Protocol":"METASYS N2 APOGEE FLN LonWorks BACnet Modbus","Nominal switching frequency":"12 kHz","Environmental characteristic":"Classes 3C1 conforming to IEC 60721-3-3 Classes 3S2 conforming to IEC 60721-3-3","Product Specific Application":"Pumps and fans in HVAC","Speed drive output frequency":"0.5...200 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11","Asynchronous motor control profile":"Voltage/frequency ratio, 2 points Voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo) Flux vector control without sensor, standard Voltage/frequency ratio - Energy Saving, quadratic U/f Voltage/frequency ratio, 5 points","Acceleration and deceleration ramps":"Automatic based on the load Linear adjustable separately from 0.01 to 3200 s","Ambient Air Temperature for Storage":"-13...158 °F (-25...70 °C)","Environment/IP degree of protection":"IP20 on upper part without blanking plate on cover IEC 61800-5-1 IP20 on upper part without blanking plate on cover IEC 60529 IP21 IEC 61800-5-1 IP21 IEC 60529 IP41 on upper part IEC 61800-5-1 IP41 on upper part IEC 60529","Ambient air temperature for operation":"14...104 °F (-10...40 °C) (without derating) 104...122 °F (40...50 °C) (with derating factor)","Variable speed drive application selection":"Building - HVAC compressor for scroll Building - HVAC fan Building - HVAC pump"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$605.00 – $1,811.07","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ph/en/product/ATV212HD11N4/variable-speed-drive-atv212-11kw-15hp-480v-3ph-emc-ip21/"},"ai":{"faq":[{"question":"Where can I buy the ATV212HD11N4 and get a price?","answer":"The ATV212HD11N4 is sourced to order against your BOM through independent distribution. Submit an RFQ for current availability and pricing — no stock-holding claim is made here."},{"question":"What compliance documentation does Schneider provide for the ATV212HD11N4?","answer":"The drive carries CE marking and complies with IEC 61800-3 (environments 1 and 2, categories C1/C2/C3), IEC 61800-5-1, and EN 55011 class A group 1. An integrated class C2 EMC filter is standard."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV212HD11N4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV212HD11N4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}