{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV212HD15N4LCD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV212HD15N4LCD","canonicalUrl":"https://aoctrl.com/schneider/ATV212HD15N4LCD","factsUrl":"https://aoctrl.com/api/mcp/products/ATV212HD15N4LCD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 212 ATV212HD15N4LCD AC drive, 15 kW / 20 hp, 480 V, 22.8 A line current, integrated C2 EMC filter, Modbus RTU, IP20, 245 x 330 x 190 mm.","salesMarkdown":"## 15 kW at 480 V — what it drives and where it fits The ATV212HD15N4LCD is a 15 kW / 20 hp Altivar 212 AC drive rated for 480 V three-phase input, drawing 22.8 A line current at 480 V and 28.5 A at 380 V. That power class covers standard 15 kW asynchronous motors on pumps, fans, and conveyors in commercial HVAC and light industrial process lines. An integrated Class C2 EMC filter is built in — no external filter needed for most European commercial installations (EN 61800-3 environment 1 category C2). The drive also carries UL Type 1 approval, so it fits North American panel builds without a separate enclosure. ## Control interface and fieldbus The drive ships with a 2-wire RS 485 port running Modbus RTU at 9600 or 19200 bps, supporting up to 247 addresses on the bus. Analog inputs include one switch-configurable voltage/current (0–10 V DC or 0–20 mA) and one configurable for voltage or PTC probe input — both 10-bit resolution. An adjustable PI regulator is built into the control loop, so closed-loop process control (pressure, flow, level) can be handled without an external controller. ## Protection coverage and environmental ratings Protection extends to drive overheating, motor thermal protection via PTC probes, short-circuit between motor phases, earth fault, DC bus overvoltage/undervoltage, input phase loss, and overspeed limiting — all monitored internally. Rated for 50/60 Hz supply, 5–95 % humidity without condensation, and operation up to 1000 m altitude without derating (to 3000 m with derating). Shock rated at 15 gn for 11 ms per IEC 60068-2-27, pollution degree 2 per IEC 61800-5-1. ## Lifecycle and sourcing Sourced to order against your BOM quantity through independent distribution.","metaTitle":"Schneider ATV212HD15N4LCD AC Drive, 15 kW / 20 hp, 480 V","metaDescription":"Schneider Altivar 212 AC drive, 15 kW / 20 hp, 480 V, 22.8 A line current. Integrated C2 EMC filter, Modbus RTU, PI regulator.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"190 mm","Width":"245 mm","Height":"330 mm","Marking":"CE","Air flow":"206 m3/h","Standards":"IEC 61800-3 EN 61800-3 environments 1 category C3 EN 55011 class A group 1 UL Type 1 EN 61800-3 environments 2 category C1 IEC 61800-3 environments 1 category C1 IEC 61800-3 environments 1 category C3 EN 61800-3 environments 2 category C3 IEC 61800-3 category C3 IEC 61800-3 category C2 IEC 61800-3 environments 2 category C2 EN 61800-3 environments 1 category C1 IEC 61800-5-1 EN 61800-5-1 IEC 61800-3 environments 2 category C1 EN 61800-3 category C2 EN 61800-3 category C3 EN 61800-3 environments 2 category C2 EN 61800-3 IEC 61800-3 environments 1 category C2 IEC 61800-3 environments 2 category C3 EN 61800-3 environments 1 category C2","EMC filter":"Class C2 EMC filter integrated","Data format":"8 bits, 1 stop, odd even or no configurable parity","Noise level":"54 dB conforming to 86/188/EEC","Option card":"Communication card for LonWorks","Speed range":"1...10","Line current":"22.8 A at 480 V 28.5 A at 380 V","Functionality":"Mid","Apparent power":"23.2 kVA at 380 V","Assembly style":"With heat sink","Connector type":"1 RJ45 1 open style","Motor power hp":"20 hp","Motor power kW":"15 kW","Output voltage":"= 1 mOhm 500 V DC for 1 minute","Speed accuracy":"+/- 10 % of nominal slip 0.2 Tn to Tn","Protection type":"Overheating protection: drive Thermal power stage: drive Short-circuit between motor phases: drive Input phase breaks: drive Overcurrent between output phases and earth: drive Overvoltages on the DC bus: drive Break on the control circuit: drive Against exceeding limit speed: drive Line supply overvoltage and undervoltage: drive Line supply undervoltage: drive Against input phase loss: drive Thermal protection: motor Motor phase break: motor With PTC probes: motor","Regulation loop":"Adjustable PI regulator","Torque accuracy":"+/- 15 %","lifecycle_stage":"mature","Local signalling":"1 LED (red) for DC bus energized","Pollution degree":"2 conforming to IEC 61800-5-1","Range of product":"Altivar 212","Shock resistance":"15 gn for 11 ms conforming to IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV212","Network frequency":"47.5...63 Hz","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3 5...95 % without dripping water conforming to IEC 60068-2-3","Transmission rate":"9600 bps or 19200 bps","Operating altitude":"1000...3000 m limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m <= 1000 m without derating","Operating position":"Vertical +/- 10 degree","Physical interface":"2-wire RS 485","Transmission frame":"RTU","Analogue input type":"VIA switch-configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 10 bits VIB configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 10 bits VIB configurable PTC probe: 0...6 probes, impedance: 1500 Ohm VIA switch-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 10 bits","Number of addresses":"1...247","Product destination":"Asynchronous motors","Switching frequency":"6...16 kHz adjustable 12...16 kHz with derating factor","Frequency resolution":"Display unit: 0.1 Hz Analog input: 0.024/50 Hz","Prospective line Isc":"22 kA","Specific application":"Centrifugal pumps and fans","Transient overtorque":"120 % of nominal motor torque +/- 10 % for 60 s","Type of polarization":"No impedance","Vibration resistance":"1.5 mm (f= 3...13 Hz) conforming to EN/IEC 60068-2-6 1 gn (f= 13...200 Hz) conforming to EN/IEC 60068-2-8","Analogue input number":"2","Braking to standstill":"By DC injection","Communication service":"Write single register (06) Write multiple registers (16) 2 words maximum Read device identification (43) Monitoring inhibitable Read holding registers (03) 2 words maximum Time out setting from 0.1 to 100 s","Supply voltage limits":"323...528 V","Analogue output number":"1","Discrete output number":"2","Power dissipation in W":"625 W","IP degree of protection":"IP20 on upper part without blanking plate on cover conforming to EN/IEC 61800-5-1 IP20 on upper part without blanking plate on cover conforming to EN/IEC 60529 IP21 conforming to EN/IEC 61800-5-1 IP21 conforming to EN/IEC 60529 IP41 on upper part conforming to EN/IEC 61800-5-1 IP41 on upper part conforming to EN/IEC 60529","Motor slip compensation":"Automatic whatever the load Adjustable Not available in voltage/frequency ratio motor control","Network number of phases":"3 phases","Continuous output current":"30.5 A at 380 V 30.5 A at 460 V","Maximum transient current":"33.6 A for 60 s","Product or component type":"Variable speed drive","[Us] rated supply voltage":"380...480 V - 15...10 %","Communication port protocol":"APOGEE FLN LonWorks BACnet METASYS N2 Modbus","Nominal switching frequency":"12 kHz","Environmental characteristic":"Classes 3C1 conforming to IEC 60721-3-3 Classes 3S2 conforming to IEC 60721-3-3","Product specific application":"Pumps and fans in HVAC","Speed drive output frequency":"0.5...200 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11","Asynchronous motor control profile":"Voltage/frequency ratio - Energy Saving, quadratic U/f Flux vector control without sensor, standard Voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo) Voltage/frequency ratio, 5 points Voltage/frequency ratio, 2 points","Acceleration and deceleration ramps":"Automatic based on the load Linear adjustable separately from 0.01 to 3200 s","Ambient air temperature for storage":"-25...70 °C","Ambient air temperature for operation":"-10...40 °C (without derating) 40...50 °C (with derating factor)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/id/en/product/ATV212HD15N4LCD/kit-variable-speed-drive-atv212-15kw-380v-3ph-lcd/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ATV212HD15N4LCD/alternatives.json"},"ai":{"faq":[{"question":"What compliance documentation does the ATV212HD15N4LCD carry?","answer":"The drive is CE marked and complies with IEC 61800-3 (EMC categories C1, C2, C3 in environments 1 and 2), EN 61800-5-1 (safety), EN 55011 Class A Group 1, and UL Type 1. The integrated EMC filter is Class C2."},{"question":"How do I get current pricing and availability for the ATV212HD15N4LCD?","answer":"Pricing and stock are confirmed at quote time against your specific BOM quantity. Submit an RFQ through this listing — availability and lead time are quoted per order."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV212HD15N4LCD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV212HD15N4LCD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}