{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV212HD22N4","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV212HD22N4","canonicalUrl":"https://aoctrl.com/schneider/ATV212HD22N4","factsUrl":"https://aoctrl.com/api/mcp/products/ATV212HD22N4","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 212 ATV212HD22N4 AC drive, 22 kW, 480 V, 3-phase, 33.1 A line current, integrated Class C2 EMC filter, IP20, 214 mm depth.","salesMarkdown":"## 22 kW VFD for pump and fan duty The ATV212HD22N4 is a 22 kW variable speed drive from the Schneider Altivar 212 series, designed for three-phase 480 VAC motor control in HVAC pumping and fan applications. Rated line current is 33.1 A at 480 V and 41.6 A at 380 V, with an apparent power of 33.2 kVA at 380 V — the 22 kW motor power rating is the continuous duty ceiling for a standard induction motor. ## EMC compliance and installation planning An integrated Class C2 EMC filter is built in, covering conducted emissions for first-environment (residential) installations per IEC 61800-3 category C2 — this avoids the need for an external filter in most commercial building applications. The drive carries CE marking and complies with IEC 61800-5-1 for safety, plus UL Type 1 enclosure rating for indoor panel mounting. Dimensions are 16.5 in (420 mm) high by 9.4 in (240 mm) wide by 8.4 in (214 mm) deep — the depth is the key constraint for shallow backpanel enclosures; allow clearance for the heatsink airflow of 214 m³/h. ## Protection and control interface Protection covers overheating of the power stage, short-circuit between motor phases, earth faults, DC bus overvoltage, input phase loss, and motor thermal protection via PTC probes — the drive self-monitors these without external relays. The control interface includes two analogue inputs (VIA switchable 0–10 VDC or 0–20 mA, VIB configurable voltage or PTC probe), an adjustable PI regulator for closed-loop process control, and a 2-wire RS-485 port running Modbus RTU at 9600 or 19200 bps. Speed accuracy is ±10 % of nominal slip from 0.2 Tn to Tn, and torque accuracy is ±15 % — adequate for pump/fan regulation but not for precision servo positioning. ## Lifecycle and sourcing Sourced through authorized distribution channels; quoted to order against the BOM quantity. Availability and current pricing are confirmed at RFQ time.","metaTitle":"Schneider ATV212HD22N4 AC Drive, 22 kW, 480 V, 3-phase VFD","metaDescription":"Schneider Electric ATV212HD22N4 Altivar 212 AC drive, 22 kW / 30 HP, 480 V 3-phase input, 33.1 A line current, integrated Class C2 EMC filter.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"8.4 in (214 mm)","Phase":"3 phase","Width":"9.4 in (240 mm)","title":"ATV212HD22N4","Height":"16.5 in (420 mm)","Marking":"CE","Air flow":"56533.8 Gal/hr(US) (214 m3/h)","Category":"US1CP4D22158","Standards":"IEC 61800-3 environments 1 category C2 IEC 61800-3 environments 1 category C2 EN 61800-3 category C3 IEC 61800-3 category C2 IEC 61800-3 IEC 61800-3 environments 2 category C2 IEC 61800-5-1 IEC 61800-3 environments 1 category C3 IEC 61800-3 environments 2 category C3 IEC 61800-3 environments 1 category C1 IEC 61800-3 category C3 IEC 61800-3 environments 2 category C3 IEC 61800-3 category C2 IEC 61800-3 environments 2 category C1 IEC 61800-3 IEC 61800-3 environments 1 category C3 IEC 61800-5-1 IEC 61800-3 environments 2 category C2 UL Type 1 IEC 61800-3 environments 1 category C1 EN 55011 class A group 1 IEC 61800-3 environments 2 category C1","EMC filter":"Class C2 EMC filter integrated","Data format":"8 bits, 1 stop, odd even or no configurable parity","Noise level":"59.9 dB 86/188/EEC","Option card":"Communication card LonWorks","Speed range":"1...10","description":"variable speed drive, Altivar 212, 22kW, 30hp, 480V, 3 phases, with EMC, IP21","Line current":"33.1 A 480 V 41.6 A 380 V","Functionality":"Mid","Apparent power":"33.2 kVA 380 V","Assembly style":"With heat sink","Connector Type":"1 RJ45 1 open style","Motor power kW":"22 kW","Output voltage":"= 1 mOhm 500 V DC for 1 minute","Speed accuracy":"+/- 10 % of nominal slip 0.2 Tn to Tn","Protection type":"Overheating protection drive Thermal power stage drive Short-circuit between motor phases drive Input phase breaks drive Overcurrent between output phases and earth drive Overvoltages on the DC bus drive Break on the control circuit drive Against exceeding limit speed drive Line supply overvoltage and undervoltage drive Line supply undervoltage drive Against input phase loss drive Thermal protection motor Motor phase break motor With PTC probes motor","Regulation loop":"Adjustable PI regulator","Torque accuracy":"+/- 15 %","lifecycle_stage":"mature","Local signalling":"1 LED (red) for DC bus energized","Pollution degree":"3 IEC 61800-5-1","Range of Product":"Altivar 212","Shock resistance":"15 gn 11 ms IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV212","Network Frequency":"47.5...63 Hz","Relative humidity":"5...95 % without condensation IEC 60068-2-3 5...95 % without dripping water IEC 60068-2-3","Transmission Rate":"9600 bps or 19200 bps","Motor starter type":"Variable speed drive","Operating altitude":"3280.84...9842.52 ft (1000...3000 m) limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m <= 3280.84 ft (1000 m) without derating","Operating position":"Vertical +/- 10 degree","Physical interface":"2-wire RS 485","Transmission frame":"RTU","Analogue input type":"VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits VIB configurable PTC probe 0...6 probes 1500 Ohm VIA switch-configurable current 0...20 mA 250 Ohm 10 bits","Number of addresses":"1...247","Product destination":"Asynchronous motors","Switching frequency":"6...16 kHz adjustable 8...16 kHz with derating factor","Frequency resolution":"Display unit 0.1 Hz Analog input 0.024/50 Hz","Prospective line Isc":"22 kA","Specific application":"HVAC","Transient overtorque":"120 % of nominal motor torque +/- 10 % 60 s","Type of polarization":"No impedance","Vibration resistance":"1.5 mm (f= 3...13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13...200 Hz) conforming to EN/IEC 60068-2-8","Analogue input number":"2","Braking to standstill":"By DC injection","Communication Service":"Write single register (06) Read device identification (43) Read holding registers (03) 2 words maximum Write multiple registers (16) 2 words maximum Time out setting from 0.1 to 100 s Monitoring inhibitable","Nbr. of units in pkg.":"1","Supply voltage limits":"323...528 V","Analogue output number":"1","Discrete output number":"2","Motor power range AC-3":"15...25 kW 380...440 V 3 phase 15...25 kW 480...500 V 3 phase","Power dissipation in W":"626 W","IP degree of protection":"IP21","Motor slip compensation":"Adjustable Not available in voltage/frequency ratio motor control Automatic whatever the load","Continuous output current":"43.5 A 380 V 43.5 A 460 V","Maximum transient current":"47.9 A 60 s","Product or Component Type":"Variable speed drive","[Us] rated supply voltage":"380...480 V - 15...10 %","Maximum Horse Power Rating":"30 hp","Communication Port Protocol":"Modbus LonWorks APOGEE FLN BACnet METASYS N2","Nominal switching frequency":"8 kHz","Environmental characteristic":"Classes 3C1 conforming to IEC 60721-3-3 Classes 3S2 conforming to IEC 60721-3-3","Product Specific Application":"Pumps and fans in HVAC","Speed drive output frequency":"0.5...200 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11","Asynchronous motor control profile":"Voltage/frequency ratio, 2 points Voltage/frequency ratio - Energy Saving, quadratic U/f Voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo) Flux vector control without sensor, standard Voltage/frequency ratio, 5 points","Acceleration and deceleration ramps":"Automatic based on the load Linear adjustable separately from 0.01 to 3200 s","Ambient Air Temperature for Storage":"-13...158 °F (-25...70 °C)","Environment/IP degree of protection":"IP20 on upper part without blanking plate on cover IEC 61800-5-1 IP20 on upper part without blanking plate on cover IEC 60529 IP21 IEC 61800-5-1 IP21 IEC 60529 IP41 on upper part IEC 61800-5-1 IP41 on upper part IEC 60529","Ambient air temperature for operation":"14...104 °F (-10...40 °C) (without derating) 104...122 °F (40...50 °C) (with derating factor)","Variable speed drive application selection":"Building - HVAC compressor for scroll Building - HVAC fan Building - HVAC pump"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,977.39 – $4,278.96","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/mk/en/product/ATV212HD22N4/variable-speed-drive-altivar-212-22kw-30hp-480v-3-phases-with-emc-ip21/"},"ai":{"faq":[{"question":"What compliance documentation does Schneider provide for the ATV212HD22N4?","answer":"The drive carries CE marking and complies with IEC 61800-3 (environments 1 and 2, categories C1 through C3), IEC 61800-5-1, EN 55011 Class A Group 1, and UL Type 1. An integrated Class C2 EMC filter is included. RoHS and REACH declarations are standard with the product documentation."},{"question":"What is the ATV212HD22N4's depth for panel layout?","answer":"The depth is 8.4 inches (214 mm). This is the dimension from the mounting surface to the front of the drive enclosure, excluding cable glands or connectors. Allow additional clearance for the heatsink airflow of 214 m³/h."},{"question":"What phase input does the ATV212HD22N4 require?","answer":"It requires a three-phase input. The line current rating is 33.1 A at 480 V and 41.6 A at 380 V, with a supply frequency range of 50–60 Hz ±5%."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV212HD22N4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV212HD22N4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}