{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV212HD30M3X","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV212HD30M3X","canonicalUrl":"https://aoctrl.com/schneider/ATV212HD30M3X","factsUrl":"https://aoctrl.com/api/mcp/products/ATV212HD30M3X","rawCanonicalId":null},"summary":{"shortDescription":"Schneider ATV212HD30M3X Motor Drives — now discontinued. Supplied from remaining channel stock; full specifications, lifecycle and same-series options are below.","salesMarkdown":"## Overview The ATV212HD30M3X is a Schneider Altivar 212 adjustable frequency AC drive rated at 30 kW / 40 hp on a 240 V AC 3-phase input, delivering 117 A output current. It carries an IP21 enclosure and is built with a heat sink for thermal management, making it a direct-fit unit for 240 V motor control applications in the Altivar 212 line. The drive supports multiple fieldbus protocols including BACnet, LonWorks, Modbus, and Metasys N2 / Apogee FLN, allowing direct integration into building management or industrial control networks without an external gateway. Analog inputs are configurable for 0–10 V DC or 0–20 mA signals, and the drive provides one analog output plus two discrete outputs for feedback or status. Control is via keypad or logic inputs, with an LED display for parameter viewing and adjustment. The drive is rated for 60 Hz operation and includes a built-in PTC probe input for motor thermal protection. ## Applications Altivar 212 drives of this power class are commonly specified for variable-torque loads such as centrifugal pumps, fans, and blowers in HVAC, water treatment, and industrial ventilation systems. The constant-torque capability also suits light conveyor and mixer applications where speed regulation improves process control and energy efficiency. The ATV212HD30M3X carries CE marking and is certified to IEC 61800-5-1 and IEC 61800-3 for EMC environments 1 and 2, categories C1 through C3, as well as UL Type 1. It also complies with California Proposition 65. No official end-of-life notice is in the evidence; the drive remains a current catalog item in the Altivar 212 series. For sourcing, submit an RFQ to confirm lead time and availability.","metaTitle":"Schneider ATV212HD30M3X Altivar 212 AC Drive, 30 kW, 40 hp, 240 V","metaDescription":"Schneider Altivar 212 ATV212HD30M3X AC drive: 30 kW / 40 hp, 240 V 3-phase input, 117 A output, IP21, heat sink, CE, IEC 61800-5-1.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Unclassified"],"specifications":{"Depth":"11.4 in (290 mm)","Phase":"3 phase","Width":"12.6 in (320 mm)","Height":"24.8 in (630 mm)","Marking":"CE","Air flow":"98009.6 Gal/hr(US) (371 m3/h)","Category":"US1CP4D22156","Standards":"IEC 61800-3 environments 2 category C1 IEC 61800-3 environments 2 category C2 IEC 61800-3 environments 1 category C2 IEC 61800-3 IEC 61800-5-1 IEC 61800-3 environments 1 category C3 IEC 61800-3 environments 1 category C1 UL Type 1 IEC 61800-3 environments 1 category C2 IEC 61800-3 environments 1 category C1 IEC 61800-3 environments 2 category C3 IEC 61800-3 environments 2 category C1 IEC 61800-3 environments 1 category C3 IEC 61800-3 IEC 61800-3 environments 2 category C3 IEC 61800-3 environments 2 category C2 IEC 61800-5-1","EMC filter":"Without EMC filter","Data format":"8 bits, 1 stop, odd even or no configurable parity","Noise level":"63.7 dB 86/188/EEC","Option card":"Communication card LonWorks","Speed range":"1...10","Line current":"113.3 A 200 V 89.5 A 240 V","Apparent power":"44.6 kVA 240 V","Assembly style":"With heat sink","Connector Type":"1 RJ45 1 open style","Motor power kW":"30 kW","Output voltage":"= 1 mOhm 500 V DC for 1 minute","Speed accuracy":"+/- 10 % of nominal slip 0.2 Tn to Tn","Protection type":"Overheating protection drive Thermal power stage drive Short-circuit between motor phases drive Input phase breaks drive Overcurrent between output phases and earth drive Overvoltages on the DC bus drive Break on the control circuit drive Against exceeding limit speed drive Line supply overvoltage and undervoltage drive Line supply undervoltage drive Against input phase loss drive Thermal protection motor Motor phase break motor With PTC probes motor","Regulation loop":"Adjustable PI regulator","Torque accuracy":"+/- 15 %","lifecycle_stage":"mature","Local signalling":"1 LED (red) for DC bus energized","Pollution degree":"3 IEC 61800-5-1","Range of Product":"Altivar 212","Shock resistance":"15 gn 11 ms IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV212","Network Frequency":"47.5...63 Hz","Relative humidity":"5...95 % without condensation IEC 60068-2-3 5...95 % without dripping water IEC 60068-2-3","Transmission Rate":"9600 bps or 19200 bps","Motor starter type":"Variable speed drive","Operating altitude":"3280.84...9842.52 ft (1000...3000 m) limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m <= 3280.84 ft (1000 m) without derating","Operating position":"Vertical +/- 10 degree","Physical interface":"2-wire RS 485","Transmission frame":"RTU","Analogue input type":"VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits VIB configurable PTC probe 0...6 probes 1500 Ohm VIA switch-configurable current 0...20 mA 250 Ohm 10 bits","Number of addresses":"1...247","Product destination":"Asynchronous motors","Switching frequency":"6...16 kHz adjustable 8...16 kHz with derating factor","Frequency resolution":"Display unit 0.1 Hz Analog input 0.024/50 Hz","Prospective line Isc":"22 kA","Specific application":"HVAC","Transient overtorque":"120 % of nominal motor torque +/- 10 % 60 s","Type of polarization":"No impedance","Vibration resistance":"1.5 mm (f= 3...13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13...200 Hz) conforming to EN/IEC 60068-2-8","Analogue input number":"2","Braking to standstill":"By DC injection","Communication Service":"Write multiple registers (16) 2 words maximum Monitoring inhibitable Time out setting from 0.1 to 100 s Read holding registers (03) 2 words maximum Read device identification (43) Write single register (06)","Nbr. of units in pkg.":"1","Supply voltage limits":"170...264 V","Analogue output number":"1","Discrete output number":"2","Motor power range AC-3":"30...50 kW 200...240 V 3 phase","Power dissipation in W":"1085 W","IP degree of protection":"IP21","Motor slip compensation":"Not available in voltage/frequency ratio motor control Adjustable Automatic whatever the load","Continuous output current":"117 A 230 V","Maximum transient current":"128.7 A 60 s","Product or Component Type":"Variable speed drive","[Us] rated supply voltage":"200...240 V - 15...10 %","Maximum Horse Power Rating":"40 hp","Communication Port Protocol":"METASYS N2 APOGEE FLN BACnet LonWorks Modbus","Nominal switching frequency":"8 kHz","Environmental characteristic":"Classes 3C1 conforming to IEC 60721-3-3 Classes 3S2 conforming to IEC 60721-3-3","Product Specific Application":"Pumps and fans in HVAC","Speed drive output frequency":"0.5...200 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11","Asynchronous motor control profile":"Voltage/frequency ratio, 2 points Voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo) Voltage/frequency ratio - Energy Saving, quadratic U/f Flux vector control without sensor, standard Voltage/frequency ratio, 5 points","Acceleration and deceleration ramps":"Automatic based on the load Linear adjustable separately from 0.01 to 3200 s","Ambient Air Temperature for Storage":"-13...158 °F (-25...70 °C)","Environment/IP degree of protection":"IP20 on upper part without blanking plate on cover IEC 61800-5-1 IP20 on upper part without blanking plate on cover IEC 60529 IP21 IEC 61800-5-1 IP21 IEC 60529 IP41 on upper part IEC 61800-5-1 IP41 on upper part IEC 60529","Ambient air temperature for operation":"14...104 °F (-10...40 °C) (without derating) 104...122 °F (40...50 °C) (with derating factor)","Variable speed drive application selection":"Building - HVAC compressor for scroll Building - HVAC fan Building - HVAC pump"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$2,651.76 – $5,945.67","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3e0bab7667d85d49a2e7ea0bd369e735.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/ATV212HD30M3X/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV212HD30M3X","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV212HD30M3X when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}