{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV212HD75N4","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV212HD75N4","canonicalUrl":"https://aoctrl.com/schneider/ATV212HD75N4","factsUrl":"https://aoctrl.com/api/mcp/products/ATV212HD75N4","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 212 ATV212HD75N4 AC drive, 75 kW / 100 HP, 3-phase 480 V, integrated Class C2 EMC filter, CE marked.","salesMarkdown":"## 75 kW at 480 V — what the rating means on the line The ATV212HD75N4 is a 75 kW variable speed drive from the Altivar 212 family, designed for 3-phase 480 V supply. At 380 V it draws 141.8 A; at 480 V the line current drops to 111.3 A — the 75 kW rating holds across the 380–480 V window, but the input current changes with voltage, so the upstream protection and cable sizing follow the 380 V figure for worst-case thermal margin. The drive carries an integrated Class C2 EMC filter, which means it meets conducted and radiated emission limits for industrial environments (first environment, restricted distribution per IEC 61800-3). No external filter needed for most industrial panels — saves a DIN-rail slot and a wiring step. ## Protection set and fault tolerance This drive covers the common failure modes without external add-ons: short-circuit between motor phases, earth faults on the output, DC bus overvoltage, input phase loss, and motor thermal protection via PTC probes. The overheating protection on the power stage means the drive throttles itself before the IGBTs let go — useful on a pump or fan load that runs near the thermal ceiling for hours. The adjustable PI regulator in the regulation loop lets it close the loop on process feedback (pressure, flow, level) without a separate controller — the drive handles the PID directly. ## Lifecycle and sourcing posture Sourced to order against the BOM quantity through independent industrial distribution.","metaTitle":"Schneider ATV212HD75N4 AC Drive, 75 kW, 480 V, 3-phase","metaDescription":"Schneider Electric ATV212HD75N4 Altivar 212 AC drive, 75 kW / 100 HP at 480 V, 3-phase input. Mature lifecycle, sourced to order. CE, integrated C2 EMC filter.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"11.4 in (290 mm)","Phase":"3 phase","Width":"12.6 in (320 mm)","Height":"24.8 in (630 mm)","Marking":"CE","Air flow":"175941.7 Gal/hr(US) (666 m3/h)","Category":"US1CP4D22158","Standards":"IEC 61800-3 category C3 IEC 61800-3 category C2 IEC 61800-3 environments 1 category C3 IEC 61800-3 UL Type 1 IEC 61800-3 environments 2 category C3 IEC 61800-3 category C2 IEC 61800-3 environments 2 category C2 IEC 61800-3 environments 1 category C1 IEC 61800-5-1 IEC 61800-3 environments 2 category C1 IEC 61800-3 environments 1 category C2 EN 61800-3 category C3 IEC 61800-3 environments 2 category C2 IEC 61800-3 environments 1 category C3 IEC 61800-3 environments 2 category C3 IEC 61800-5-1 IEC 61800-3 IEC 61800-3 environments 1 category C1 IEC 61800-3 environments 1 category C2 EN 55011 class A group 1 IEC 61800-3 environments 2 category C1","EMC filter":"Class C2 EMC filter integrated","Data format":"8 bits, 1 stop, odd even or no configurable parity","Noise level":"63.7 dB 86/188/EEC","Option card":"Communication card LonWorks","Speed range":"1...10","Line current":"141.8 A 380 V 111.3 A 480 V","Functionality":"Mid","Apparent power":"105.3 kVA 380 V","Assembly style":"With heat sink","Connector Type":"1 open style 1 RJ45","Motor power kW":"75 kW","Output voltage":"= 1 mOhm 500 V DC for 1 minute","Speed accuracy":"+/- 10 % of nominal slip 0.2 Tn to Tn","Protection type":"Overheating protection drive Thermal power stage drive Short-circuit between motor phases drive Input phase breaks drive Overcurrent between output phases and earth drive Overvoltages on the DC bus drive Break on the control circuit drive Against exceeding limit speed drive Line supply overvoltage and undervoltage drive Line supply undervoltage drive Against input phase loss drive Thermal protection motor Motor phase break motor With PTC probes motor","Regulation loop":"Adjustable PI regulator","Torque accuracy":"+/- 15 %","lifecycle_stage":"mature","Local signalling":"1 LED (red) for DC bus energized","Pollution degree":"3 IEC 61800-5-1","Range of Product":"Altivar 212","Shock resistance":"15 gn 11 ms IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV212","Network Frequency":"47.5...63 Hz","Relative humidity":"5...95 % without condensation IEC 60068-2-3 5...95 % without dripping water IEC 60068-2-3","Transmission Rate":"9600 bps or 19200 bps","Motor starter type":"Variable speed drive","Operating altitude":"3280.84...9842.52 ft (1000...3000 m) limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m <= 3280.84 ft (1000 m) without derating","Operating position":"Vertical +/- 10 degree","Physical interface":"2-wire RS 485","Transmission frame":"RTU","Analogue input type":"VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits VIB configurable PTC probe 0...6 probes 1500 Ohm VIA switch-configurable current 0...20 mA 250 Ohm 10 bits","Number of addresses":"1...247","Product destination":"Asynchronous motors","Switching frequency":"6...16 kHz adjustable 8...16 kHz with derating factor","Frequency resolution":"Display unit 0.1 Hz Analog input 0.024/50 Hz","Prospective line Isc":"22 kA","Specific application":"HVAC","Transient overtorque":"120 % of nominal motor torque +/- 10 % 60 s","Type of polarization":"No impedance","Vibration resistance":"1.5 mm (f= 3...13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13...200 Hz) conforming to EN/IEC 60068-2-8","Analogue input number":"2","Braking to standstill":"By DC injection","Communication Service":"Read device identification (43) Write single register (06) Time out setting from 0.1 to 100 s Monitoring inhibitable Read holding registers (03) 2 words maximum Write multiple registers (16) 2 words maximum","Nbr. of units in pkg.":"1","Supply voltage limits":"323...528 V","Analogue output number":"1","Discrete output number":"2","Motor power range AC-3":"55...100 kW 380...440 V 3 phase 55...100 kW 480...500 V 3 phase","Power dissipation in W":"1945 W","IP degree of protection":"IP21","Motor slip compensation":"Not available in voltage/frequency ratio motor control Automatic whatever the load Adjustable","Continuous output current":"160 A 380 V 160 A 460 V","Maximum transient current":"176 A 60 s","Product or Component Type":"Variable speed drive","[Us] rated supply voltage":"380...480 V - 15...10 %","Maximum Horse Power Rating":"100 hp","Communication Port Protocol":"METASYS N2 Modbus APOGEE FLN BACnet LonWorks","Nominal switching frequency":"8 kHz","Environmental characteristic":"Classes 3C1 conforming to IEC 60721-3-3 Classes 3S2 conforming to IEC 60721-3-3","Product Specific Application":"Pumps and fans in HVAC","Speed drive output frequency":"0.5...200 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11","Asynchronous motor control profile":"Voltage/frequency ratio, 5 points Voltage/frequency ratio - Energy Saving, quadratic U/f Voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo) Voltage/frequency ratio, 2 points Flux vector control without sensor, standard","Acceleration and deceleration ramps":"Automatic based on the load Linear adjustable separately from 0.01 to 3200 s","Ambient Air Temperature for Storage":"-13...158 °F (-25...70 °C)","Environment/IP degree of protection":"IP20 on upper part without blanking plate on cover IEC 61800-5-1 IP20 on upper part without blanking plate on cover IEC 60529 IP21 IEC 61800-5-1 IP21 IEC 60529 IP41 on upper part IEC 61800-5-1 IP41 on upper part IEC 60529","Ambient air temperature for operation":"14...104 °F (-10...40 °C) (without derating) 104...122 °F (40...50 °C) (with derating factor)","Variable speed drive application selection":"Building - HVAC compressor for scroll Building - HVAC fan Building - HVAC pump"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$4,140.20 – $8,747.67","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/vn/en/product/ATV212HD75N4/variable-speed-drive-altivar-212-75kw-100hp-480v-3-phases-with-emc-ip21/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ATV212HD75N4/alternatives.json"},"ai":{"faq":[{"question":"What compliance marks does the ATV212HD75N4 carry?","answer":"CE marked, with IEC 61800-3 (EMC categories C1 through C3 for both environments 1 and 2), IEC 61800-5-1 (safety), and EN 55011 Class A Group 1. The integrated Class C2 EMC filter covers most industrial installations without an external filter."},{"question":"What is the ATV212HD75N4's physical size?","answer":"The drive measures 24.8 inches high by 12.6 inches wide by 11.4 inches deep (630 mm x 320 mm x 290 mm). Vertical mounting within ±10 degrees is specified; allow clearance above and below for the 666 m³/h airflow through the heatsink."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV212HD75N4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV212HD75N4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}