{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV212WD15N4","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV212WD15N4","canonicalUrl":"https://aoctrl.com/schneider/ATV212WD15N4","factsUrl":"https://aoctrl.com/api/mcp/products/ATV212WD15N4","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 212 ATV212WD15N4 AC drive, 15 kW, 3-phase 480 V, 22.6 A line current, integrated Class C2 EMC filter, CE/UL/CSA.","salesMarkdown":"## What this drive delivers on a 480 V line The ATV212WD15N4 is an Altivar 212 AC drive rated for 15 kW output on a 3-phase 480 V supply — sized for asynchronous motors in pump, fan, and conveyor duty where the load profile stays within the drive's constant-torque curve. Line current at 480 V is 22.6 A; at 380 V it draws 28.4 A, so the upstream protection and cable sizing follow the higher figure when the supply is on the low side of the tolerance band. ## Regulatory and installation fit The integrated Class C2 EMC filter covers most industrial power-distribution layouts without an external filter. Pollution degree 2 per IEC 61800-5-1 and a 15 gn / 11 ms shock rating per IEC 60068-2-27 mean it handles the vibration and contamination levels typical of a panel-mounted drive near a motor or gearbox. ## Lifecycle and sourcing posture The lifecycle stage is marked as mature — this is not a new-introduction or end-of-life flag, but it means the drive has been in the field long enough that spares and replacements are stable through distribution. No official successor order code is recorded. ## Protection and control depth Built-in protections cover overheating, short-circuit between motor phases, input phase loss, overcurrent between output phases and earth, DC-bus overvoltage, and motor thermal protection with PTC probe support — the drive can shut down on a winding overtemperature without an external relay. An adjustable PI regulator is onboard for closed-loop process control — pressure, flow, or level loops can be tuned directly in the drive without a separate controller. The analogue input stage is switch-configurable between voltage (0–10 V DC) and current (0–20 mA) with 10-bit resolution, and one input can serve as a PTC probe interface for motor temperature feedback.","metaTitle":"Schneider ATV212WD15N4 AC Drive (VFD) 480V, 15 kW, 3-phase","metaDescription":"Schneider Electric ATV212WD15N4 Altivar 212 AC drive, 15 kW, 3-phase 480 V, 22.6 A line current, integrated C2 EMC filter, CE/UL/CSA. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"12.4 in (315 mm)","Phase":"3 phase","Width":"11.4 in (290 mm)","title":"ATV212WD15N4","Height":"22.05 in (560 mm)","Marking":"CE","Category":"US1CP4D22157","Standards":"IEC 61800-5-1 IEC 61800-3 environments 1 category C1 IEC 61800-3 environments 1 category C2 IEC 61800-3 environments 1 category C3 IEC 61800-3 environments 2 category C1 IEC 61800-3 environments 2 category C2 IEC 61800-3 environments 2 category C3 CE UL CSA C-Tick N1831 GOST","EMC filter":"Class C2 EMC filter integrated","Data format":"8 bits, 1 stop, odd even or no configurable parity","Noise level":"57.4 dB 86/188/EEC","Option card":"Communication card LonWorks","Speed range":"1...10","description":"variable speed drive, Altivar 212, 15kW, 20hp, 480V, 3 phases, with EMC class C2, IP55","Line current":"22.6 A 480 V 28.4 A 380 V","Functionality":"Mid","Apparent power":"23.2 kVA 380 V","Assembly style":"With heat sink","Connector Type":"1 RJ45 1 open style","Motor power kW":"15 kW","Output voltage":"= 1 mOhm 500 V DC for 1 minute","Speed accuracy":"+/- 10 % of nominal slip 0.2 Tn to Tn","Protection type":"Overheating protection drive Thermal power stage drive Short-circuit between motor phases drive Input phase breaks drive Overcurrent between output phases and earth drive Overvoltages on the DC bus drive Break on the control circuit drive Against exceeding limit speed drive Line supply overvoltage and undervoltage drive Line supply undervoltage drive Against input phase loss drive Thermal protection motor Motor phase break motor With PTC probes motor","Regulation loop":"Adjustable PI regulator","Torque accuracy":"+/- 15 %","lifecycle_stage":"mature","Local signalling":"1 LED (red) for DC bus energized","Pollution degree":"2 IEC 61800-5-1","Range of Product":"Altivar 212","Shock resistance":"15 gn 11 ms IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV212","Network Frequency":"47.5...63 Hz","Relative humidity":"5...95 % without condensation IEC 60068-2-3 5...95 % without dripping water IEC 60068-2-3","Transmission Rate":"9600 bps or 19200 bps","Operating altitude":"3280.84...9842.52 ft (1000...3000 m) limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m <= 3280.84 ft (1000 m) without derating","Operating position":"Vertical +/- 10 degree","Physical interface":"2-wire RS 485","Transmission frame":"RTU","Analogue input type":"VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits VIB configurable PTC probe 0...6 probes 1500 Ohm VIA switch-configurable current 0...20 mA 250 Ohm 10 bits","Number of addresses":"1...247","Product destination":"Asynchronous motors","Switching frequency":"6...16 kHz adjustable 12...16 kHz with derating factor","Frequency resolution":"Display unit 0.1 Hz Analog input 0.024/50 Hz","Prospective line Isc":"22 kA","Specific application":"HVAC","Transient overtorque":"120 % of nominal motor torque +/- 10 % 60 s","Type of polarization":"No impedance","Vibration resistance":"1.5 mm (f= 3...13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13...200 Hz) conforming to EN/IEC 60068-2-8","Analogue input number":"2","Braking to standstill":"By DC injection","Communication Service":"Time out setting from 0.1 to 100 s Write single register (06) Write multiple registers (16) 2 words maximum Read device identification (43) Monitoring inhibitable Read holding registers (03) 2 words maximum","Nbr. of units in pkg.":"1","Supply voltage limits":"323...528 V","Analogue output number":"1","Discrete output number":"2","IP degree of protection":"IP55","Motor slip compensation":"Not available in voltage/frequency ratio motor control Automatic whatever the load Adjustable","Continuous output current":"30.5 A 380 V 30.5 A 460 V","Maximum transient current":"33.6 A 60 s","Product or Component Type":"Variable speed drive","[Us] rated supply voltage":"380...480 V - 15...10 %","Maximum Horse Power Rating":"20 hp","Communication Port Protocol":"Modbus METASYS N2 BACnet LonWorks APOGEE FLN","Nominal switching frequency":"12 kHz","Environmental characteristic":"Classes 3C1 conforming to IEC 60721-3-3 Classes 3S2 conforming to IEC 60721-3-3","Product Specific Application":"Pumps and fans in HVAC","Speed drive output frequency":"0.5...200 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11","Asynchronous motor control profile":"Voltage/frequency ratio - Energy Saving, quadratic U/f Voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo) Voltage/frequency ratio, 2 points Flux vector control without sensor, standard Voltage/frequency ratio, 5 points","Acceleration and deceleration ramps":"Automatic based on the load Linear adjustable separately from 0.01 to 3200 s","Ambient Air Temperature for Storage":"-13...158 °F (-25...70 °C)","Environment/IP degree of protection":"IP55 IEC 61800-5-1 IP55 IEC 60529","Ambient air temperature for operation":"14...104 °F (-10...40 °C) (without derating) 104...122 °F (40...50 °C) (with derating factor)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,564.64 – $3,454.67","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/be/en/product/ATV212WD15N4/variable-speed-drive-altivar-212-15kw-20hp-480v-3-phases-with-emc-class-c2-ip55/"},"ai":{"faq":[{"question":"How do I get pricing and availability for the ATV212WD15N4?","answer":"We source this drive to order against the BOM quantity."},{"question":"What compliance documentation does Schneider provide for this drive?","answer":"The ATV212WD15N4 carries CE, UL, CSA, and C-Tick markings and meets IEC 61800-5-1 (safety) and IEC 61800-3 (EMC) for environments 1 and 2 up to category C3. The integrated Class C2 EMC filter is listed."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV212WD15N4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV212WD15N4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}