{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV212WD75N4","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV212WD75N4","canonicalUrl":"https://aoctrl.com/schneider/ATV212WD75N4","factsUrl":"https://aoctrl.com/api/mcp/products/ATV212WD75N4","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 212 series, ATV212WD75N4 AC drive, 75 kW, 3-phase 480 V, 141.8 A line current at 380 V, integrated Class C2 EMC filter, IP20.","salesMarkdown":"## 75 kW at 480 V — what the ratings mean for the load The ATV212WD75N4 is a 75 kW Altivar 212 drive designed for three-phase asynchronous motors on 380–480 V supplies. At 380 V it draws 141.8 A line current; at 480 V that drops to 111.3 A — the lower current at the higher voltage means the input wiring and upstream protection can be sized for the 480 V figure when that is the nominal supply. The integrated Class C2 EMC filter covers most industrial environments without an external filter — it meets EN 55011 Class A Group 1 and IEC 61800-3 Category C2/C3 conducted and radiated emission limits. For installations on IT or corner-grounded TN systems the altitude limit drops to 2000 m; above that derate current 1 % per 100 m up to 3000 m. ## Protection and I/O that match the application The drive includes thermal protection for both the power stage and the motor, plus short-circuit detection between motor phases and between output phases and earth. Input phase loss, DC bus overvoltage, and line undervoltage are all monitored — the protection list covers the common failure modes that take down a pump or fan drive on a production line. The analog input VIA is switch-configurable for voltage (0–10 V DC, 30 kOhm) or current (0–20 mA, 250 Ohm, 10-bit resolution). VIB is configurable as a second voltage input or as a PTC probe input for motor thermal protection — useful when the motor is remote and a separate PTC relay is not wanted in the panel. RS-485 Modbus RTU is on the RJ45 port at 9600 or 19200 bps, 1–247 addresses, with configurable parity. The LonWorks option card slot is present but not populated — if the site uses LonWorks building automation, factor the card cost into the BOM.","metaTitle":"Schneider ATV212WD75N4 AC Drive, 75 kW, 480 V, 3-Phase","metaDescription":"Schneider Electric ATV212WD75N4 Altivar 212 AC drive, 75 kW / 100 HP, 480 V 3-phase input, 141.8 A line current at 380 V. Mature lifecycle; sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"14.3 in (364 mm)","Phase":"3 phase","Width":"14.3 in (362 mm)","title":"ATV212WD75N4","Height":"39.4 in (1000 mm)","Marking":"CE","Category":"US1CP4D22158","Standards":"IEC 61800-3 environments 2 category C2 IEC 61800-3 environments 2 category C3 IEC 61800-3 category C2 IEC 61800-3 category C3 IEC 61800-3 environments 1 category C2 IEC 61800-3 IEC 61800-5-1 IEC 61800-3 environments 1 category C3 IEC 61800-3 environments 2 category C3 EN 61800-3 category C3 IEC 61800-3 environments 1 category C2 IEC 61800-5-1 IEC 61800-3 environments 1 category C1 IEC 61800-3 environments 2 category C1 EN 55011 class A group 1 IEC 61800-3 IEC 61800-3 category C2 IEC 61800-3 environments 2 category C1 IEC 61800-3 environments 1 category C3 IEC 61800-3 environments 1 category C1 IEC 61800-3 environments 2 category C2","EMC filter":"Class C2 EMC filter integrated","Data format":"8 bits, 1 stop, odd even or no configurable parity","Noise level":"63.7 dB 86/188/EEC","Option card":"Communication card LonWorks","Speed range":"1...10","description":"variable speed drive, Altivar 212, 75kW, 100hp, 480V, 3 phases, with EMC class C2, IP55","Line current":"141.8 A 380 V 111.3 A 480 V","Functionality":"Mid","Apparent power":"105.3 kVA 380 V","Assembly style":"With heat sink","Connector Type":"1 RJ45 1 open style","Motor power kW":"75 kW","Output voltage":"= 1 mOhm 500 V DC for 1 minute","Speed accuracy":"+/- 10 % of nominal slip 0.2 Tn to Tn","Protection type":"Overheating protection drive Thermal power stage drive Short-circuit between motor phases drive Input phase breaks drive Overcurrent between output phases and earth drive Overvoltages on the DC bus drive Break on the control circuit drive Against exceeding limit speed drive Line supply overvoltage and undervoltage drive Line supply undervoltage drive Against input phase loss drive Thermal protection motor Motor phase break motor With PTC probes motor","Regulation loop":"Adjustable PI regulator","Torque accuracy":"+/- 15 %","lifecycle_stage":"mature","Local signalling":"1 LED (red) for DC bus energized","Pollution degree":"3 IEC 61800-5-1","Range of Product":"Altivar 212","Shock resistance":"15 gn 11 ms IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV212","Network Frequency":"47.5...63 Hz","Relative humidity":"5...95 % without condensation IEC 60068-2-3 5...95 % without dripping water IEC 60068-2-3","Transmission Rate":"9600 bps or 19200 bps","Operating altitude":"3280.84...9842.52 ft (1000...3000 m) limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m <= 3280.84 ft (1000 m) without derating","Operating position":"Vertical +/- 10 degree","Physical interface":"2-wire RS 485","Transmission frame":"RTU","Analogue input type":"VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits VIB configurable PTC probe 0...6 probes 1500 Ohm VIA switch-configurable current 0...20 mA 250 Ohm 10 bits","Number of addresses":"1...247","Product destination":"Asynchronous motors","Switching frequency":"6...16 kHz adjustable 8...16 kHz with derating factor","Frequency resolution":"Display unit 0.1 Hz Analog input 0.024/50 Hz","Prospective line Isc":"22 kA","Specific application":"HVAC","Transient overtorque":"120 % of nominal motor torque +/- 10 % 60 s","Type of polarization":"No impedance","Vibration resistance":"1.5 mm (f= 3...13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13...200 Hz) conforming to EN/IEC 60068-2-8","Analogue input number":"2","Braking to standstill":"By DC injection","Communication Service":"Write single register (06) Time out setting from 0.1 to 100 s Read device identification (43) Write multiple registers (16) 2 words maximum Monitoring inhibitable Read holding registers (03) 2 words maximum","Nbr. of units in pkg.":"1","Supply voltage limits":"323...528 V","Analogue output number":"1","Discrete output number":"2","IP degree of protection":"IP55","Motor slip compensation":"Adjustable Not available in voltage/frequency ratio motor control Automatic whatever the load","Continuous output current":"160 A 380 V 160 A 460 V","Maximum transient current":"176 A 60 s","Product or Component Type":"Variable speed drive","[Us] rated supply voltage":"380...480 V - 15...10 %","Maximum Horse Power Rating":"100 hp","Communication Port Protocol":"BACnet METASYS N2 Modbus LonWorks APOGEE FLN","Nominal switching frequency":"8 kHz","Environmental characteristic":"Classes 3C1 conforming to IEC 60721-3-3 Classes 3S2 conforming to IEC 60721-3-3","Product Specific Application":"Pumps and fans in HVAC","Speed drive output frequency":"0.5...200 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11","Asynchronous motor control profile":"Voltage/frequency ratio - Energy Saving, quadratic U/f Flux vector control without sensor, standard Voltage/frequency ratio, 5 points Voltage/frequency ratio, 2 points Voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo)","Acceleration and deceleration ramps":"Linear adjustable separately from 0.01 to 3200 s Automatic based on the load","Ambient Air Temperature for Storage":"-13...158 °F (-25...70 °C)","Environment/IP degree of protection":"IP55 IEC 61800-5-1 IP55 IEC 60529","Ambient air temperature for operation":"14...104 °F (-10...40 °C) (without derating) 104...122 °F (40...50 °C) (with derating factor)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$625.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/be/en/product/ATV212WD75N4/variable-speed-drive-altivar-212-75kw-100hp-480v-3-phases-with-emc-class-c2-ip55/"},"ai":{"faq":[{"question":"What is the ATV212WD75N4 used for?","answer":"It is a variable frequency drive for three-phase asynchronous motors up to 75 kW / 100 HP on 380–480 V supplies. Typical loads are pumps, fans, and conveyors in water treatment, HVAC, and light industrial applications."},{"question":"What compliance documentation does Schneider provide for the ATV212WD75N4?","answer":"The drive carries CE marking and complies with IEC 61800-3 (EMC categories C1–C3), IEC 61800-5-1 (safety), and EN 55011 Class A Group 1. The integrated C2 EMC filter covers most industrial installations without external filtering."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV212WD75N4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV212WD75N4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}