{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV212WU22N4CZH28","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV212WU22N4CZH28","canonicalUrl":"https://aoctrl.com/schneider/ATV212WU22N4CZH28","factsUrl":"https://aoctrl.com/api/mcp/products/ATV212WU22N4CZH28","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 212 series, ATV212WU22N4CZH28, variable speed drive for asynchronous motors, 2.2 kW / 3 hp, 380…480 V three-phase, integrated Class C1 EMC filter, CE marked.","salesMarkdown":"The ATV212WU22N4CZH28 is a Schneider Altivar 212 variable speed drive rated for 2.2 kW / 3 hp asynchronous motor loads on a 380…480 V three-phase supply. Line current draws 4.6 A at 380 V and 3.7 A at 480 V, with apparent power of 3.9 kVA at 380 V. The integrated Class C1 EMC filter covers EN 61800-3 environments 1 and 2 categories C1 through C3, so it meets residential and industrial emission limits without an external filter — saves a DIN-rail slot and a wiring step. Switching frequency is adjustable from 6 to 16 kHz; above 12 kHz you derate the output current. Speed range runs 1 to 10 with ±10 % slip compensation from 0.2 Tn to Tn. Torque accuracy sits at ±15 %. The drive includes an adjustable PI regulator for closed-loop process control — pump, fan, conveyor applications where you want a setpoint, not just open-loop speed. Dimensions are 215 mm wide, 297 mm tall, 192 mm deep — that depth (192 mm) is the key number for enclosure depth clearance; a standard 300 mm deep panel leaves you about 100 mm behind the door for wiring and finger clearance. Assembly style is with a heat sink, so it needs free air circulation around the fins. Operating position is vertical ±10°, pollution degree 3 per IEC 61800-5-1. Relative humidity range 5…95 % non-condensing. Altitude derating starts above 1000 m; corner-grounded distribution networks are limited to 2000 m. ## Communications and I/O Physical interface is 2-wire RS-485 with Modbus RTU frame at 9600 or 19200 bps, 8 bits, 1 stop, parity configurable. Supports up to 247 addresses on the bus. An optional LonWorks communication card is available. Analog inputs are switch-configurable for voltage (0…10 V DC, 30 kΩ impedance) or current (0…20 mA, 250 Ω), 10-bit resolution. One input also accepts PTC probes for motor thermal protection.","metaTitle":"Schneider ATV212WU22N4CZH28 Altivar 212 VFD, 2.2 kW, C1 EMC","metaDescription":"Schneider ATV212WU22N4CZH28 Altivar 212 variable speed drive, 2.2 kW / 3 hp, 380-480 V, integrated C1 EMC filter. Mature lifecycle, sourced to order. CE marked per EN 61800-3.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"192 mm","Width":"215 mm","Height":"297 mm","Marking":"CE","Standards":"EN 61800-3 environments 1 category C3 IEC 61800-3 environments 2 category C3 EN 61800-3 environments 2 category C1 IEC 61800-5-1 EN 61800-3 environments 2 category C2 IEC 61800-3 environments 2 category C2 EN 61800-5-1 IEC 61800-3 category C1 IEC 61800-3 environments 1 category C1 IEC 61800-3 environments 2 category C1 EN 61800-3 environments 1 category C2 EN 61800-3 environments 2 category C3 IEC 61800-3 environments 1 category C3 EN 61800-3 IEC 61800-3 environments 1 category C2 IEC 61800-3 EN 55011 group 1 class B EN 61800-3 environments 1 category C1 EN 61800-3 category C1","EMC filter":"Class C1 EMC filter integrated","Data format":"8 bits, 1 stop, odd even or no configurable parity","Noise level":"48 dB conforming to 86/188/EEC","Option card":"Communication card for LonWorks","Speed range":"1...10","Line current":"4.6 A at 380 V 3.7 A at 480 V","Apparent power":"3.9 kVA at 380 V","Assembly style":"With heat sink","Connector type":"1 open style 1 RJ45","Motor power hp":"3 hp","Motor power kW":"2.2 kW","Output voltage":"= 1 mOhm 500 V DC for 1 minute","Speed accuracy":"+/- 10 % of nominal slip 0.2 Tn to Tn","Protection type":"Overheating protection: drive Thermal power stage: drive Short-circuit between motor phases: drive Input phase breaks: drive Overcurrent between output phases and earth: drive Overvoltages on the DC bus: drive Break on the control circuit: drive Against exceeding limit speed: drive Line supply overvoltage and undervoltage: drive Line supply undervoltage: drive Against input phase loss: drive Thermal protection: motor Motor phase break: motor With PTC probes: motor","Regulation loop":"Adjustable PI regulator","Torque accuracy":"+/- 15 %","lifecycle_stage":"mature","Local signalling":"1 LED (red) for DC bus energized","Pollution degree":"3 conforming to IEC 61800-5-1","Range of product":"Altivar 212","Shock resistance":"15 gn for 11 ms conforming to IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV212","Network frequency":"47.5...63 Hz","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3 5...95 % without dripping water conforming to IEC 60068-2-3","Transmission rate":"9600 bps or 19200 bps","Operating altitude":"1000...3000 m limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m <= 1000 m without derating","Operating position":"Vertical +/- 10 degree","Physical interface":"2-wire RS 485","Transmission frame":"RTU","Analogue input type":"VIA switch-configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 10 bits VIB configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 10 bits VIB configurable PTC probe: 0...6 probes, impedance: 1500 Ohm VIA switch-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 10 bits","Number of addresses":"1...247","Product destination":"Asynchronous motors","Switching frequency":"6...16 kHz adjustable 12...16 kHz with derating factor","Frequency resolution":"Display unit: 0.1 Hz Analog input: 0.024/50 Hz","Prospective line Isc":"5 kA","Transient overtorque":"120 % of nominal motor torque +/- 10 % for 60 s","Type of polarization":"No impedance","Vibration resistance":"1.5 mm (f= 3...13 Hz) conforming to EN/IEC 60068-2-6 1 gn (f= 13...200 Hz) conforming to EN/IEC 60068-2-8","Analogue input number":"2","Braking to standstill":"By DC injection","Communication service":"Monitoring inhibitable Read device identification (43) Write single register (06) Read holding registers (03) 2 words maximum Write multiple registers (16) 2 words maximum Time out setting from 0.1 to 100 s","Supply voltage limits":"323...528 V","Analogue output number":"1","Discrete output number":"2","IP degree of protection":"IP54 conforming to EN/IEC 61800-5-1 IP54 conforming to EN/IEC 60529","Motor slip compensation":"Adjustable Not available in voltage/frequency ratio motor control Automatic whatever the load","Network number of phases":"3 phases","Continuous output current":"5.1 A at 380 V 5.1 A at 460 V","Maximum transient current":"5.6 A for 60 s","Product or component type":"Variable speed drive","[Us] rated supply voltage":"380...480 V - 15...10 %","Communication port protocol":"METASYS N2 APOGEE FLN Modbus BACnet LonWorks","Nominal switching frequency":"12 kHz","Environmental characteristic":"Classes 3C1 conforming to IEC 60721-3-3 Classes 3S2 conforming to IEC 60721-3-3","Product specific application":"Pumps and fans in HVAC","Speed drive output frequency":"0.5...200 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11","Asynchronous motor control profile":"Flux vector control without sensor, standard Voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo) Voltage/frequency ratio - Energy Saving, quadratic U/f Voltage/frequency ratio, 5 points Voltage/frequency ratio, 2 points","Acceleration and deceleration ramps":"Automatic based on the load Linear adjustable separately from 0.01 to 3200 s","Ambient air temperature for storage":"-25...70 °C","Ambient air temperature for operation":"-10...40 °C (without derating) 40...50 °C (with derating factor)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/db23f1501b4acdd4ca211d839bf13a8c.pdf","sourceUrl":"https://www.se.com/uk/en/product/ATV212WU22N4CZH28/variable-speed-drive-atv212-ip54-2-2-kw-3x380-480-v/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ATV212WU22N4CZH28/alternatives.json"},"ai":{"faq":[{"question":"What is the depth of ATV212WU22N4CZH28?","answer":"The depth is 192 mm. That is the dimension from the mounting surface to the front of the drive — critical for enclosure depth planning."},{"question":"What compliance documentation does ATV212WU22N4CZH28 carry?","answer":"CE marked per EN 61800-3 and EN 61800-5-1. The integrated C1 EMC filter covers all EN 61800-3 environment categories for both environment 1 and 2. Also complies with EN 55011 Group 1 Class B. Pollution degree 3 per IEC 61800-5-1."},{"question":"Where can I buy ATV212WU22N4CZH28?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm position."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV212WU22N4CZH28","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV212WU22N4CZH28 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}