{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV212WU40N4CZH28","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV212WU40N4CZH28","canonicalUrl":"https://aoctrl.com/schneider/ATV212WU40N4CZH28","factsUrl":"https://aoctrl.com/api/mcp/products/ATV212WU40N4CZH28","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar 212 series, ATV212WU40N4CZH28, variable frequency drive for asynchronous motors, 4 kW / 5 hp, 380-480 V, integrated Class C1 EMC filter, IP20, 208 x 230 x 340 mm.","salesMarkdown":"The ATV212WU40N4CZH28 is a Schneider Altivar 212 variable frequency drive sized for a 4 kW (5 hp) 3-phase asynchronous motor on 380-480 V supply. Integrated Class C1 EMC filter covers conducted emissions for residential and light industrial environments — no external filter needed for most installations. Switching frequency is adjustable 6-16 kHz; derate above 12 kHz. Line current draw is 8.2 A at 380 V, 6.5 A at 480 V. Apparent power rating is 6.9 kVA at 380 V. The drive includes a built-in PI regulator for closed-loop process control applications like constant pressure or flow. Protection coverage is comprehensive: thermal drive and motor protection, short-circuit between motor phases, input phase loss, DC bus overvoltage, earth fault, and PTC probe input for motor overtemperature. The drive also monitors line supply undervoltage and overvoltage. The ATV212WU40N4CZH28 is classified as mature lifecycle — still available through distribution channels but not actively promoted for new designs. ## Integration & compliance Mounts vertically (±10°) with heat sink for convection cooling. Dimensions: 208 mm deep, 230 mm wide, 340 mm high. RS-485 physical interface with Modbus RTU protocol at 9600 or 19200 bps supports up to 247 addresses on the bus. CE marked. Complies with IEC 61800-3 for EMC environments 1 and 2, categories C1, C2, C3, and IEC 61800-5-1 for safety. EN 55011 Group 1 Class B conducted emissions. Pollution degree 3 per IEC 61800-5-1. Operating altitude up to 1000 m without derating; 1000-3000 m with 1% derating per 100 m.","metaTitle":"Schneider ATV212WU40N4CZH28 Altivar 212 VFD, 4 kW, 5 hp, C1","metaDescription":"Schneider ATV212WU40N4CZH28 Altivar 212 variable frequency drive, 4 kW / 5 hp, 380-480 V, integrated Class C1 EMC filter. Mature lifecycle. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"208 mm","Width":"230 mm","Height":"340 mm","Marking":"CE","Standards":"IEC 61800-3 environments 1 category C3 IEC 61800-3 IEC 61800-3 environments 1 category C1 IEC 61800-5-1 IEC 61800-3 category C1 EN 61800-3 environments 1 category C2 EN 61800-3 environments 1 category C1 EN 61800-3 EN 61800-3 environments 1 category C3 EN 61800-3 category C1 IEC 61800-3 environments 2 category C2 EN 61800-3 environments 2 category C2 IEC 61800-3 environments 1 category C2 EN 61800-3 environments 2 category C3 EN 61800-3 environments 2 category C1 EN 61800-5-1 EN 55011 group 1 class B IEC 61800-3 environments 2 category C1 IEC 61800-3 environments 2 category C3","EMC filter":"Class C1 EMC filter integrated","Data format":"8 bits, 1 stop, odd even or no configurable parity","Noise level":"55 dB conforming to 86/188/EEC","Option card":"Communication card for LonWorks","Speed range":"1...10","Line current":"6.5 A at 480 V 8.2 A at 380 V","Apparent power":"6.9 kVA at 380 V","Assembly style":"With heat sink","Connector type":"1 open style 1 RJ45","Motor power hp":"5 hp","Motor power kW":"4 kW","Output voltage":"= 1 mOhm 500 V DC for 1 minute","Speed accuracy":"+/- 10 % of nominal slip 0.2 Tn to Tn","Protection type":"Overheating protection: drive Thermal power stage: drive Short-circuit between motor phases: drive Input phase breaks: drive Overcurrent between output phases and earth: drive Overvoltages on the DC bus: drive Break on the control circuit: drive Against exceeding limit speed: drive Line supply overvoltage and undervoltage: drive Line supply undervoltage: drive Against input phase loss: drive Thermal protection: motor Motor phase break: motor With PTC probes: motor","Regulation loop":"Adjustable PI regulator","Torque accuracy":"+/- 15 %","lifecycle_stage":"mature","Local signalling":"1 LED (red) for DC bus energized","Pollution degree":"3 conforming to IEC 61800-5-1","Range of product":"Altivar 212","Shock resistance":"15 gn for 11 ms conforming to IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV212","Network frequency":"47.5...63 Hz","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3 5...95 % without dripping water conforming to IEC 60068-2-3","Transmission rate":"9600 bps or 19200 bps","Operating altitude":"1000...3000 m limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m <= 1000 m without derating","Operating position":"Vertical +/- 10 degree","Physical interface":"2-wire RS 485","Transmission frame":"RTU","Analogue input type":"VIA switch-configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 10 bits VIB configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 10 bits VIB configurable PTC probe: 0...6 probes, impedance: 1500 Ohm VIA switch-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 10 bits","Number of addresses":"1...247","Product destination":"Asynchronous motors","Switching frequency":"6...16 kHz adjustable 12...16 kHz with derating factor","Frequency resolution":"Display unit: 0.1 Hz Analog input: 0.024/50 Hz","Prospective line Isc":"5 kA","Transient overtorque":"120 % of nominal motor torque +/- 10 % for 60 s","Type of polarization":"No impedance","Vibration resistance":"1.5 mm (f= 3...13 Hz) conforming to EN/IEC 60068-2-6 1 gn (f= 13...200 Hz) conforming to EN/IEC 60068-2-8","Analogue input number":"2","Braking to standstill":"By DC injection","Communication service":"Read holding registers (03) 2 words maximum Monitoring inhibitable Read device identification (43) Time out setting from 0.1 to 100 s Write multiple registers (16) 2 words maximum Write single register (06)","Supply voltage limits":"323...528 V","Analogue output number":"1","Discrete output number":"2","IP degree of protection":"IP54 conforming to EN/IEC 61800-5-1 IP54 conforming to EN/IEC 60529","Motor slip compensation":"Not available in voltage/frequency ratio motor control Adjustable Automatic whatever the load","Network number of phases":"3 phases","Continuous output current":"9.1 A at 380 V 9.1 A at 460 V","Maximum transient current":"10 A for 60 s","Product or component type":"Variable speed drive","[Us] rated supply voltage":"380...480 V - 15...10 %","Communication port protocol":"BACnet METASYS N2 APOGEE FLN Modbus LonWorks","Nominal switching frequency":"12 kHz","Environmental characteristic":"Classes 3C1 conforming to IEC 60721-3-3 Classes 3S2 conforming to IEC 60721-3-3","Product specific application":"Pumps and fans in HVAC","Speed drive output frequency":"0.5...200 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11","Asynchronous motor control profile":"Voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo) Voltage/frequency ratio, 5 points Flux vector control without sensor, standard Voltage/frequency ratio - Energy Saving, quadratic U/f Voltage/frequency ratio, 2 points","Acceleration and deceleration ramps":"Automatic based on the load Linear adjustable separately from 0.01 to 3200 s","Ambient air temperature for storage":"-25...70 °C","Ambient air temperature for operation":"-10...40 °C (without derating) 40...50 °C (with derating factor)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/99b0de2af669a6068310a2a848d3cb04.pdf","sourceUrl":"https://www.se.com/uk/en/product/ATV212WU40N4CZH28/variable-speed-drive-atv212-ip54-4-kw-3x380-480-v/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ATV212WU40N4CZH28/alternatives.json"},"ai":{"faq":[{"question":"What is ATV212WU40N4CZH28's listed depth?","answer":"The ATV212WU40N4CZH28 has a depth of 208 mm, width of 230 mm, and height of 340 mm."},{"question":"What compliance documentation does this drive provide?","answer":"CE marked. Complies with IEC 61800-3 (EMC environments 1 and 2, categories C1/C2/C3), IEC 61800-5-1 (safety), and EN 55011 Group 1 Class B. Integrated Class C1 EMC filter."},{"question":"Where can I buy ATV212WU40N4CZH28?","answer":"This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV212WU40N4CZH28","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV212WU40N4CZH28 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}