{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV320D11M3C412","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV320D11M3C412","canonicalUrl":"https://aoctrl.com/schneider/ATV320D11M3C412","factsUrl":"https://aoctrl.com/api/mcp/products/ATV320D11M3C412","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Altivar Solar ATV320D11M3C412, compact VFD for solar applications, 11 kW heavy duty, without integrated EMC filter.","salesMarkdown":"Schneider ATV320D11M3C412 is a compact VFD from the Altivar Solar line, rated 11 kW heavy duty. It pulls 60.9 A at 200 V heavy duty input (51.4 A at 240 V). Switching frequency is adjustable from 2 to 16 kHz—derate above 4 kHz if you need full output current. No EMC filter on board, so plan external filtering for CE residence. The communication slot takes an optional Ethernet IP/Modbus TCP card. ## Sourcing reality This drive is current production—no end-of-life notice. Standard lead time applies; quote to order against RFQ. Compliance markings: CE, UR, UKCA, RCM. Meets IEC 61800-5-1. Power factor 0.604 at 230 V.","metaTitle":"Schneider ATV320D11M3C412 Altivar Solar Drive, 11 kW HD","metaDescription":"Schneider ATV320D11M3C412 Altivar Solar drive, 11 kW heavy duty, without EMC filter. Current production, sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 240V"],"specifications":{"Depth":"7.8 in (198.0 mm)","Width":"7.09 in (180 mm)","title":"ATV320D11M3C412","Height":"13.0 in (330 mm)","Marking":"CE UR UKCA RCM","Variant":"Standard version","Category":"US1CP4B22153","Standards":"IEC 61800-5-1","EMC filter":"Without EMC filter","Data format":"8 bits, configurable odd, even or no parity","Noise level":"58 dB","Option card":"communication module, Ethernet IP/Modbus TCP","description":"Variable speed drive, Altivar Solar, 11kW, 200 to 240V, 3 phases, compact","Line current":"60.9 A 200 V heavy duty) 51.4 A 240 V heavy duty)","Power factor":"0.604 at 230 V","Mounting Mode":"Wall mount","Apparent power":"21.4 kVA 240 V heavy duty)","Assembly style":"With heat sink","Braking torque":"170 % with braking resistor","Motor power kW":"11 kW heavy duty","Speed accuracy":"+/- 10 % of nominal slip 0.2 Tn to Tn","Protection type":"Input phase breaks drive Overcurrent between output phases and earth drive Overheating protection drive Short-circuit between motor phases drive Thermal protection drive","Regulation loop":"Adjustable PID regulator","lifecycle_stage":"current","Local signalling":"1 LED (red) for drive fault 1 LED (red) for CANopen error 1 LED (green) for CANopen run","Method of access":"Slave CANopen","Pollution degree":"2","Range of Product":"Altivar Solar","Network Frequency":"50-60 Hz","Relay output type":"Configurable relay logic R1A 1 NO 100000 cycles Configurable relay logic R1B 1 NC 100000 cycles Configurable relay logic R1C Configurable relay logic R2A 1 NO 100000 cycles Configurable relay logic R2C","Operating altitude":"3280.84...6561.68 ft (1000...2000 m) with current derating 1 % per 100 m <= 3280.84 ft (1000 m) without derating","Operating position":"Vertical +/- 10 degree","Analogue input type":"AI1 voltage 0...10 V DC 30 kOhm 10 bits AI2 bipolar differential voltage +/- 10 V DC 30 kOhm 10 bits AI3 current 0...20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration) 250 Ohm 10 bits","Discrete input type":"STO safe torque off, 24 V DC1.5 kOhm DI1...DI6 logic inputs, 24 V DC 30 V) DI5 programmable as pulse input 0...30 kHz, 24 V DC 30 V)","Format of the drive":"Compact","Number of addresses":"1...247 1...126","Relay output number":"2","Switching frequency":"2...16 kHz adjustable 4...16 kHz with derating factor","Analogue output type":"Software-configurable current AQ1 0...20 mA 800 Ohm 10 bits Software-configurable voltage AQ1 0...10 V DC 470 Ohm 10 bits","Discrete input logic":"Positive logic (source) Negative logic (sink)","Discrete output type":"Open collector DQ+ 0...1 kHz 30 V DC 100 mA Open collector DQ- 0...1 kHz 30 V DC 100 mA","Overvoltage category":"II","Prospective line Isc":"22 kA","Transient overtorque":"170...200 % of nominal motor torque","Type of polarization":"No impedance","Analogue input number":"3","Braking to standstill":"By DC injection","Discrete input number":"7","Electrical connection":"Screw terminal 0.5...1.5 mm² analog input Screw terminal analog output Screw terminal","Nbr. of units in pkg.":"1","Volume of cooling air":"41211.6 Gal/hr(US) (156.0 m3/h)","Analogue output number":"1","Discrete output number":"3","Maximum output voltage":"240 V","Nominal Output Current":"54.0 A","Power dissipation in W":"Fan 468.0 W 200 V 4 kHz","IP degree of protection":"IP20","Motor slip compensation":"Automatic whatever the load Adjustable 0...300 % Not available in voltage/frequency ratio (2 or 5 points)","Brake chopper integrated":"True","Maximum output frequency":"0.599 kHz","Short-circuit protection":"thermal protection","Maximum switching current":"Relay output R1A, R1B, R1C resistive, cos phi = 1 3 A 250 V AC Relay output R1A, R1B, R1C resistive, cos phi = 1 3 A 30 V DC Relay output R1A, R1B, R1C, R2A, R2C inductive, cos phi = 0.4 7 ms 2 A 250 V AC Relay output R1A, R1B, R1C, R2A, R2C inductive, cos phi = 0.4 7 ms 2 A 30 V DC Relay output R2A, R2C resistive, cos phi = 1 5 A 250 V AC Relay output R2A, R2C resistive, cos phi = 1 5 A 30 V DC","Maximum transient current":"81.0 A 60 s","Minimum switching current":"Relay output R1A, R1B, R1C, R2A, R2C 5 mA 24 V DC","Product or Component Type":"Variable speed drive","[Us] rated supply voltage":"200...240 V - 15...10 %","Communication Port Protocol":"Modbus serial CANopen","Nominal switching frequency":"4 kHz","Product Specific Application":"Pumping applications","4 Quadrant Operation Possible":"True","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11","With sft fct Safe Stop 2 (SS2)":"False","Maximum Input Current per Phase":"60.9 A","Ambient air transport temperature":"-13...158 °F (-25...70 °C)","Synchronous motor control profile":"Vector control without sensor","Asynchronous motor control profile":"Voltage/frequency ratio, 5 points Flux vector control without sensor, standard Voltage/frequency ratio - Energy Saving, quadratic U/f Flux vector control without sensor - Energy Saving Voltage/frequency ratio, 2 points","Base load current at high overload":"1.5 A","Acceleration and deceleration ramps":"Linear U S CUS Ramp switching Acceleration/deceleration ramp adaptation Acceleration/deceleration automatic stop with DC injection Automatic adaptation of ramp if braking capacity exceeded, by using resistor Linear adjustable separately from 0.01 to 6000 s","Ambient Air Temperature for Storage":"-13...158 °F (-25...70 °C)","Ambient air temperature for operation":"14...122 °F (-10...50 °C) without derating 122...140 °F (50...60 °C) with derating factor","Environmental class (during operation)":"Class 3C3 according to IEC 60721-3-3 Class 3S2 according to IEC 60721-3-3","With safety function Safe Stop 1 (SS1)":"True","With safety function Safe Position (SP)":"False","With safety function Safe Direction (SDI)":"False","With safety function Safe torque off (STO)":"True","With safety function Safe programmable logic":"False","With safety function Safe Speed Monitor (SSM)":"False","Permitted relative humidity (during operation)":"Class 3K5 according to EN 60721-3","Relative symmetric network frequency tolerance":"5 %","With safety function Safe Operating Stop (SOS)":"False","With safety function Safely Limited Speed (SLS)":"True","With safety function Safely Limited Position (SLP)":"False","Maximum acceleration under shock impact (during operation)":"150 m/s² at 11 ms","Maximum deflection under vibratory load (during operation)":"1.5 mm at 2...13 Hz","Maximum acceleration under vibrational stress (during operation)":"10 m/s² at 13...200 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,751.52","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/th/en/product/ATV320D11M3C412/variable-speed-drive-altivar-solar-11kw-200-to-240v-3-phases-compact/"},"ai":{"faq":[{"question":"What compliance markings does the ATV320D11M3C412 carry?","answer":"It carries CE, UR, UKCA, and RCM markings and complies with IEC 61800-5-1."},{"question":"What are the physical dimensions of the ATV320D11M3C412?","answer":"Height 13.0 in, width 7.09 in, depth 7.8 in. It is a wall-mount compact drive."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV320D11M3C412","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV320D11M3C412 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}