{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV320D11N4C","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV320D11N4C","canonicalUrl":"https://aoctrl.com/schneider/ATV320D11N4C","factsUrl":"https://aoctrl.com/api/mcp/products/ATV320D11N4C","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Machine ATV320 series, ATV320D11N4C AC drive, 11 kW heavy duty, 480 V, 22.2 kVA, compact format, wall mount.","salesMarkdown":"## Drive rating and motor match The ATV320D11N4C is rated 11 kW heavy duty at 480 V, delivering 22.2 kVA apparent power — sized for a 15 HP motor on a pump, fan, or conveyor where the load profile stays within the heavy-duty current envelope. Line current draw is 36.6 A at 380 V heavy duty and 25.6 A at 500 V heavy duty — the supply cable and upstream protection must be sized for the 380 V figure if the installation runs at that voltage. ## Fieldbus and I/O complement The drive accepts plug-in communication modules for CANopen, EtherCAT, Profibus DP V1, PROFINET, Ethernet Powerlink, EtherNet/IP, and DeviceNet — the base unit ships without a card, so order the matching module for your control network. Seven digital inputs (DI1–DI6 plus STO), three analogue inputs (voltage, bipolar differential voltage, and current), and one analogue output are available for local control loops and sensor feedback — the adjustable PID regulator handles closed-loop process regulation without an external controller. ## Protection and environmental coverage Built-in protections cover input phase loss, output phase-to-earth shorts, motor overheat, drive overcurrent, and thermal overload — the drive handles short-circuit between motor phases without external fusing for the motor branch. Marked CE, ATEX, UL, CSA, EAC, and RCM — the ATEX marking indicates it can be installed in a non-hazardous area driving a motor in a classified zone, provided the motor and cabling meet the zone requirements. ## Physical fit and mounting Wall-mount format, 330 mm high by 180 mm wide by 198 mm deep — the compact envelope fits a standard 600 mm wide panel with clearance for cooling air (156 m³/h required). Operating position is vertical ±10°, and the switching frequency is adjustable from 2 to 16 kHz with derating above 4 kHz — mounting in a horizontal orientation or restricting airflow will force a lower carrier frequency to stay within thermal limits.","metaTitle":"Schneider ATV320D11N4C AC Drive, 11 kW Heavy Duty, 480 V","metaDescription":"Schneider Electric ATV320D11N4C Altivar Machine AC drive, 11 kW heavy duty, 480 V, 22.2 kVA. Current production. CE, UL, CSA, EAC, RCM. Sourced per RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"7.8 in (198.0 mm)","Width":"7.09 in (180 mm)","title":"ATV320D11N4C","Height":"13.0 in (330 mm)","Marking":"CE ATEX UL CSA EAC RCM","Variant":"Standard version","Category":"US1CP4B22148","Standards":"IEC 61800-5-1","EMC filter":"Integrated","Option card":"communication module, CANopen communication module, EtherCAT communication module, Profibus DP V1 communication module, PROFINET communication module, Ethernet Powerlink communication module, EtherNet/IP communication module, DeviceNet","description":"variable speed drive, ATV320, 11 kW, 380...500 V, 3 phases, compact","Line current":"36.6 A 380 V heavy duty) 25.6 A 500 V heavy duty)","Mounting Mode":"Wall mount","Apparent power":"22.2 kVA 500 V heavy duty)","Motor power kW":"11 kW heavy duty","Speed accuracy":"+/- 10 % of nominal slip 0.2 Tn to Tn","Protection type":"Input phase breaks drive Overcurrent between output phases and earth drive Overheating protection drive Short-circuit between motor phases drive Thermal protection drive","Regulation loop":"Adjustable PID regulator","lifecycle_stage":"current","Method of access":"Slave CANopen","Pollution degree":"2","Range of Product":"Altivar Machine ATV320","Network Frequency":"50-60 Hz","Relay output type":"Configurable relay logic R1A 1 NO 100000 cycles Configurable relay logic R1B 1 NC 100000 cycles Configurable relay logic R1C Configurable relay logic R2A 1 NO 100000 cycles Configurable relay logic R2C","Operating position":"Vertical +/- 10 degree","Analogue input type":"AI1 voltage 0...10 V DC 30 kOhm 10 bits AI2 bipolar differential voltage +/- 10 V DC 30 kOhm 10 bits AI3 current 0...20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration) 250 Ohm 10 bits","Discrete input type":"STO safe torque off, 24 V DC1.5 kOhm DI1...DI6 logic inputs, 24 V DC 30 V) DI5 programmable as pulse input 0...30 kHz, 24 V DC 30 V)","Format of the drive":"Compact","Switching frequency":"2...16 kHz adjustable 4...16 kHz with derating factor","Analogue output type":"Software-configurable current AQ1 0...20 mA 800 Ohm 10 bits Software-configurable voltage AQ1 0...10 V DC 470 Ohm 10 bits","Discrete input logic":"Positive logic (source) Negative logic (sink)","Discrete output type":"Open collector DQ+ 0...1 kHz 30 V DC 100 mA Open collector DQ- 0...1 kHz 30 V DC 100 mA","Overvoltage category":"III","Prospective line Isc":"22 kA","Transient overtorque":"170...200 % of nominal motor torque","Analogue input number":"3","Braking to standstill":"By DC injection","Discrete input number":"7","Nbr. of units in pkg.":"1","Volume of cooling air":"41211.6 Gal/hr(US) (156.0 m3/h)","Analogue output number":"1","Discrete output number":"3","Maximum output voltage":"500 V","Nominal Output Current":"27.7 A","Power dissipation in W":"Fan 370 W 380 V 4 kHz","IP degree of protection":"IP20","Motor slip compensation":"Automatic whatever the load Adjustable 0...300 % Not available in voltage/frequency ratio (2 or 5 points)","Brake chopper integrated":"True","Maximum output frequency":"0.599 kHz","Maximum switching current":"Relay output R1A, R1B, R1C resistive, cos phi = 1 3 A 250 V AC Relay output R1A, R1B, R1C resistive, cos phi = 1 3 A 30 V DC Relay output R1A, R1B, R1C, R2A, R2C inductive, cos phi = 0.4 7 ms 2 A 250 V AC Relay output R1A, R1B, R1C, R2A, R2C inductive, cos phi = 0.4 7 ms 2 A 30 V DC Relay output R2A, R2C resistive, cos phi = 1 5 A 250 V AC Relay output R2A, R2C resistive, cos phi = 1 5 A 30 V DC","Minimum switching current":"Relay output R1A, R1B, R1C, R2A, R2C 5 mA 24 V DC","Product or Component Type":"Variable speed drive","[Us] rated supply voltage":"380...500 V - 15...10 %","Maximum Horse Power Rating":"15 hp","Communication Port Protocol":"Modbus serial CANopen","Nominal switching frequency":"4 kHz","Product Specific Application":"Complex machines","4 Quadrant Operation Possible":"True","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11","With sft fct Safe Stop 2 (SS2)":"False","Maximum Input Current per Phase":"36.6 A","Ambient air transport temperature":"-13...158 °F (-25...70 °C)","Synchronous motor control profile":"Vector control without sensor","Asynchronous motor control profile":"Voltage/frequency ratio, 5 points Flux vector control without sensor, standard Voltage/frequency ratio - Energy Saving, quadratic U/f Flux vector control without sensor - Energy Saving Voltage/frequency ratio, 2 points","Base load current at high overload":"27.7 A","Acceleration and deceleration ramps":"Linear U S CUS Ramp switching Acceleration/deceleration ramp adaptation Acceleration/deceleration automatic stop with DC injection","Ambient Air Temperature for Storage":"-13...158 °F (-25...70 °C)","Ambient air temperature for operation":"14...122 °F (-10...50 °C) without derating 122...140 °F (50...60 °C) with derating factor","Environmental class (during operation)":"Class 3C3 according to IEC 60721-3-3 Class 3S2 according to IEC 60721-3-3","With safety function Safe Stop 1 (SS1)":"True","With safety function Safe Position (SP)":"False","With safety function Safe Direction (SDI)":"False","With safety function Safe torque off (STO)":"True","With safety function Safe programmable logic":"False","With safety function Safe Speed Monitor (SSM)":"False","Permitted relative humidity (during operation)":"Class 3K5 according to EN 60721-3","Relative symmetric network frequency tolerance":"5 %","With safety function Safe Operating Stop (SOS)":"False","With safety function Safely Limited Speed (SLS)":"True","With safety function Safely Limited Position (SLP)":"False","Maximum acceleration under shock impact (during operation)":"150 m/s² at 11 ms","Maximum deflection under vibratory load (during operation)":"1.5 mm at 2...13 Hz","Maximum acceleration under vibrational stress (during operation)":"10 m/s² at 13...200 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$637.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ph/en/product/ATV320D11N4C/variable-speed-drive-atv320-11-kw-380500-v-3-phases-compact/"},"ai":{"faq":[{"question":"What is the transient overtorque capability of the ATV320D11N4C?","answer":"The drive delivers 170–200 % of nominal motor torque for transient overloads — enough to break a stuck pump or accelerate a high-inertia fan without tripping on overcurrent."},{"question":"Does the ATV320D11N4C include an EMC filter?","answer":"Yes, the integrated EMC filter covers conducted emissions for the 480 V supply — no external filter needed for most industrial installations, though a line reactor may still be required for harmonic mitigation."},{"question":"What compliance documentation does Schneider provide for this drive?","answer":"The drive carries CE, ATEX, UL, CSA, EAC, and RCM markings, covering EU machinery directive, North American safety listing, Eurasian customs union, and Australian/New Zealand EMC requirements. RoHS and REACH declarations are standard with the product documentation."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV320D11N4C","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV320D11N4C when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}