{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV340D55N4E","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV340D55N4E","canonicalUrl":"https://aoctrl.com/schneider/ATV340D55N4E","factsUrl":"https://aoctrl.com/api/mcp/products/ATV340D55N4E","rawCanonicalId":null},"summary":{"shortDescription":"Schneider ATV340D55N4E Motor Drives.","salesMarkdown":"## Overview The ATV340D55N4E: On the network side it speaks EtherNet/IP, Modbus TCP, and Modbus serial out of the box, and its control terminals include 3 analog inputs, 8 discrete inputs, 3 relay outputs, and 2 analog outputs. Safe torque off is built into the input stage. ## I/O comparison vs ATV340D22N4 Compared to the ATV340D22N4, the ATV340D55N4E carries 3 analog inputs versus 2, 8 discrete inputs versus 5, and 2 analog outputs versus 1. That extra I/O matters when the application needs more feedback channels or multi-zone control without adding an expansion module. The drive carries CE marking and complies with IEC 61800-3, IEC 61800-5-1, IEC 60721-3, IEC 61508, IEC 13849-1, UL 618000-5-1, UL 508C, and IEC 61000-3-12. It also lists California Proposition 65. Schneider provides the full declaration of conformity and installation manual with the unit.","metaTitle":"Schneider ATV340D55N4E Altivar Machine ATV340 drive, 75 kW, 106 A output","metaDescription":"Schneider ATV340D55N4E Altivar Machine ATV340 variable speed drive: 75 kW, 106 A output, 131.3 A input, 3-phase, IP20, integrated Class C3 EMC filter, EtherNet/IP and Modbus TCP.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"12.2 in (309.0 mm)","Phase":"3 phase","Width":"10.7 in (271.0 mm)","Height":"35.7 in (908.0 mm)","Marking":"CE","Variant":"Standard version","Category":"US1CP4B22183","Isolation":"Between power and control terminals","Standards":"IEC 61800-3 IEC 61800-5-1 IEC 60721-3 IEC 61508 IEC 13849-1 UL 618000-5-1 UL 508C IEC 61000-3-12","EMC filter":"Class C3 EMC filter integrated","Data format":"8 bits, configurable odd, even or no parity","Noise level":"62.4 dB","Option card":"communication module, PROFINET communication module, DeviceNet communication module, CANopen communication module, EtherCAT","Line current":"131.3 A 380 V with internal line choke normal duty) 112.7 A 480 V with internal line choke normal duty) 98.9 A 380 V with internal line choke heavy duty) 86.9 A 480 V with internal line choke heavy duty) 98.9 A 86.9 A","Maximum THDI":"<48 % 80 % load IEC 61000-3-12","Mounting Mode":"Wall mount","Apparent power":"93.7 kVA 480 V normal duty) 72.2 kVA 480 V heavy duty)","Assembly style":"With heat sink","Connector Type":"3 RJ45","Motor power kW":"75 kW normal duty 55 kW heavy duty","Output voltage":"<= power supply voltage","Protection type":"Thermal protection motor Safe torque off motor Motor phase loss motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent drive Output overcurrent between motor phase and earth drive Output overcurrent between motor phases drive Short-circuit between motor phase and earth drive Short-circuit between motor phases drive Motor phase loss drive DC Bus overvoltage drive Line supply overvoltage drive Line supply undervoltage drive Input supply loss drive Exceeding limit speed drive Break on the control circuit drive","Regulation loop":"Adjustable PID regulator","Type of cooling":"Forced convection","lifecycle_stage":"current","Method of access":"Slave Modbus RTU Slave Modbus TCP","Pollution degree":"2 IEC 61800-5-1","Range of Product":"Altivar Machine ATV340","Supply frequency":"50...60 Hz +/- 5 %","Relay output type":"Relay outputs R1A Relay outputs R1C 100000 cycles Relay outputs R2A Relay outputs R2C 100000 cycles","Transmission Rate":"4.8 kbit/s 9.6 kbit/s 19.2 kbit/s 38.4 kbit/s","Operating altitude":"<= 4800 m with current derating above 1000m","Operating position":"Vertical +/- 10 degree","Physical interface":"2-wire RS 485","Transmission frame":"RTU","Analogue input type":"AI1 software-configurable current 0...20 mA 250 Ohm 12 bits AI1 software-configurable temperature probe or water level sensor AI1 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits AI2 software-configurable voltage - 10...10 V DC 31.5 kOhm 12 bits","Discrete input type":"PTI safe torque off 0...30 kHz, 24 V DC 30 V) DI1...DI5 programmable as pulse input, 24 V DC 30 V)3.5 kOhm programmable","Number of addresses":"1...247","Relay output number":"3","Switching frequency":"1...8 kHz adjustable 2.5...8 kHz with derating factor","Analogue output type":"Software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits Software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits","Degree of protection":"UL type 1","Discrete output type":"Programmable output DQ1, DQ2 30 V DC 100 mA","Overvoltage category":"Class III","Prospective line Isc":"50 kA","Type of polarization":"No impedance","Analogue input number":"3","Braking to standstill":"By DC injection","Discrete input number":"8","Electrical connection":"Control screw terminal 0.75...1.5 mm² AWG 18...AWG 16 DC bus screw terminal 70...120 mm² AWG 1/0...250 kcmil Line side screw terminal 95...120 mm² AWG 3/0...250 kcmil Motor screw terminal 95...120 mm² AWG 3/0...250 kcmil","Nbr. of units in pkg.":"1","Volume of cooling air":"77932.2 Gal/hr(US) (295.0 m3/h)","Analogue output number":"2","Discrete output number":"1.0","Maximum output voltage":"480 V","Nominal Output Current":"106.0 A","Power dissipation in W":"Natural convection 115 W 380 V 4 kHz heavy duty) Forced convection 917 W 380 V 4 kHz heavy duty) Natural convection 158 W 380 V 4 kHz normal duty) Forced convection 1359 W 380 V 4 kHz normal duty)","IP degree of protection":"IP20","Motor slip compensation":"Not available in permanent magnet motor law Automatic whatever the load Can be suppressed Adjustable","Number Of Preset Speeds":"16 preset speeds","Brake chopper integrated":"True","Maximum output frequency":"0.599 kHz","Continuous output current":"145 A 4 kHz normal duty 106 A 4 kHz heavy duty","Maximum switching current":"Relay output R1C resistive, cos phi = 1 3 A 250 V AC Relay output R1C resistive, cos phi = 1 3 A 30 V DC Relay output R1C inductive, cos phi = 0.4 7 ms 2 A 250 V AC Relay output R1C inductive, cos phi = 0.4 7 ms 2 A 30 V DC Relay output R2C resistive, cos phi = 1 5 A 250 V AC Relay output R2C resistive, cos phi = 1 5 A 30 V DC Relay output R2C inductive, cos phi = 0.4 7 ms 2 A 250 V AC Relay output R2C inductive, cos phi = 0.4 7 ms 2 A 30 V DC","Maximum transient current":"174 A 60 s normal duty) 159 A 60 s heavy duty) 174 A 2 s normal duty) 159 A 2 s heavy duty)","Minimum switching current":"Relay output R1B 5 mA 24 V DC Relay output R2C 5 mA 24 V DC","Product or Component Type":"Variable speed drive","[Us] rated supply voltage":"380...480 V - 15...10 %","Maximum Horse Power Rating":"100 hp normal duty 75 hp heavy duty","Communication Port Protocol":"EtherNet/IP Modbus TCP Modbus serial","Nominal switching frequency":"2.5 kHz","Environment/Pollution degree":"2","Product Specific Application":"Machine","4 Quadrant Operation Possible":"True","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","With sft fct Safe Stop 2 (SS2)":"False","Maximum Input Current per Phase":"131.3 A","Ambient air transport temperature":"-40...158 °F (-40...70 °C)","Base load current at low overload":"145.0 A","Synchronous motor control profile":"Reluctance motor Permanent magnet motor","Asynchronous motor control profile":"Variable torque standard Optimized torque mode Constant torque standard","Base load current at high overload":"106.0 A","Acceleration and deceleration ramps":"Linear adjustable separately from 0.01...9999 s S, U or customized","Ambient Air Temperature for Storage":"-40...158 °F (-40...70 °C)","Ambient air temperature for operation":"5...122 °F (-15...50 °C) without derating vertical position) 122...140 °F (50...60 °C) with derating factor vertical position)","Environmental class (during operation)":"Class 3C3 according to IEC 60721-3-3 Class 3S3 according to IEC 60721-3-3","With safety function Safe Stop 1 (SS1)":"True","With safety function Safe Position (SP)":"False","With safety function Safe Direction (SDI)":"False","With safety function Safe torque off (STO)":"True","With safety function Safe programmable logic":"False","With safety function Safe Speed Monitor (SSM)":"False","Permitted relative humidity (during operation)":"Class 3K5 according to EN 60721-3","With safety function Safe Operating Stop (SOS)":"False","With safety function Safely Limited Speed (SLS)":"True","With safety function Safely Limited Position (SLP)":"False","Maximum acceleration under shock impact (during operation)":"150 m/s² at 11 ms","Maximum deflection under vibratory load (during operation)":"1.5 mm at 2...13 Hz","Maximum acceleration under vibrational stress (during operation)":"10 m/s² at 13...200 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$4,088.00 – $11,345.38","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5b24804ab0e48a81db6096cb1b235ec1.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/ATV340D55N4E/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV340D55N4E","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV340D55N4E when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}