{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV350U15N4FS","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV350U15N4FS","canonicalUrl":"https://aoctrl.com/schneider/ATV350U15N4FS","factsUrl":"https://aoctrl.com/api/mcp/products/ATV350U15N4FS","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Machine ATV350, ATV350U15N4FS, 1.5 kW, 3-phase 400-480 V, 6.3 A output, STO safety function, integrated C2 EMC filter.","salesMarkdown":"The Schneider Electric ATV350U15N4FS is an Altivar Machine ATV350 drive sized for a 1.5 kW asynchronous or synchronous motor on a 3-phase 400-480 V supply. It delivers 6.3 A output current over a 1-599 Hz frequency range, with a 2-16 kHz switching frequency that derates 0.5 % per additional 100 m above 1000 m altitude. The integrated Class C2 EMC filter covers 10 m cable runs, meeting IEC 61800-3 environments 1 category C2 and 2 category C3. STO (Safe Torque Off) is built in per IEC 61508 and IEC 13849-1. Wall-mounted unit, dimensions 20.6 in wide x 12.2 in high x 9.2 in deep (522 x 310 x 233 mm). Natural air cooling (AN) — no fan to maintain. The M12 I/O connector base handles EtherCAT, EtherNet/IP, Modbus TCP, and PROFINET via two 100BASE-FX Ethernet ports. Internal 24 V DC supply for logic inputs; discrete inputs are 12 V DC compatible. An incremental encoder input (24 V) is provided for closed-loop feedback on synchronous motors. ## Protection and compliance Protection covers line supply phase loss, motor phase loss, overvoltage/undervoltage, overheating, motor overload (with PTC probes), short-circuit between motor phases, and ground faults. Marked CE, UL, CULus, IEC, UKCA. Pollution degree 2, operating altitude 1000 m with derating, humidity 5-95 % non-condensing. The 3-phase input derates 2.5 % per °C above rated ambient.","metaTitle":"Schneider ATV350U15N4FS Altivar Machine Drive, 1.5 kW, 3-pha","metaDescription":"Schneider Electric ATV350U15N4FS Altivar Machine ATV350 drive for 1.5 kW motors, 3-phase 400-480 V, integrated C2 EMC filter, STO safety. Current production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"9.2 in (233 mm)","Width":"20.6 in (522 mm)","Height":"12.2 in (310 mm)","Current":"6.3 A 400...480 V conveying applications)","Voltage":"460 V","Frequency":"45...65 Hz","Output Current":"6.3 A","Product Status":"Active","Pollution Degree":"2","Temp Storage Max":"60 °C","Temp Storage Min":"-30 °C","Operating Position":"Horizontal","Temp Operating Max":"60 °C","Temp Operating Min":"-30 °C","Temperature Storage":"-22...140 °F (-30...60 °C)","Discrete Input Logic":"Programmable digital input digital I/O, 0...0.8 V, 11...24 V","Main Product Or Component Type":"Variable speed drive"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2e4a507faf55fb4c23d0a1e372a7b036.pdf","sourceUrl":"https://www.se.com/us/en/product/ATV350U15N4FS/variable-speed-drive-altivar-machine-atv350-application-i-o-fieldbus-safety-1-5kw-2hp-400-to-480v-ip54/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ATV350U15N4FS/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV350U15N4FS","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV350U15N4FS when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}