{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV350U15N4W","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV350U15N4W","canonicalUrl":"https://aoctrl.com/schneider/ATV350U15N4W","factsUrl":"https://aoctrl.com/api/mcp/products/ATV350U15N4W","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Altivar Machine ATV350, basic version, 1.5 kW, 3-phase 400-480 V, 6.3 A output, STO safety, integrated C2 EMC filter.","salesMarkdown":"The Schneider ATV350U15N4W is a basic version Altivar Machine ATV350 drive, sized for 1.5 kW asynchronous or synchronous motors on 400-480 V three-phase supply. It delivers 6.3 A continuous output current across a 1-599 Hz frequency range, with an integrated Class C2 EMC filter for conducted emissions compliance up to 10 m cable runs. The drive includes STO (Safe Torque Off) as a standard safety function, meeting IEC 61508 and IEC 13849-1 requirements for safe-stop integration. The 6.3 A output current is rated for standard conveying applications — that's the duty point where the drive delivers full rated current without derating. For other load profiles or ambient temperatures above 40 °C, the 3-phase design includes a current derating of 2.5 % per °C, so panel placement and airflow matter. The drive is naturally air-cooled (AN), meaning no fan to fail, but it needs clear space around the wall-mounted enclosure for convection. Switching frequency is adjustable from 2 to 16 kHz; above the default, you lose output current capacity at the rate of 0.5 % per additional 100 m of altitude above 1000 m. At sea level, the 2-16 kHz range covers most motor noise and efficiency trade-offs, but if you need full rated current at 16 kHz, check the thermal derating curve in the manual. The drive carries CE, UL, CULus, IEC, and UKCA markings, and complies with IEC 61800-5-1 (safety), IEC 61800-3 (EMC environments 1 category C2 and 2 category C3), UL 508C, IEC 60721-3 (environmental), and IEC 61508 / IEC 13849-1 (functional safety). The integrated EMC filter covers conducted emissions for both C2 and C3 environments, so no external filter is needed for most installations. Documentation includes the standard EU Declaration of Conformity and manufacturer's test certificates.","metaTitle":"Schneider ATV350U15N4W Altivar Machine Drive, 1.5 kW, STO","metaDescription":"Schneider ATV350U15N4W Altivar Machine ATV350 drive, 1.5 kW, 6.3 A output, STO safety, C2 EMC filter, current production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"9.2 in (233 mm)","Phase":"3 phase with current derating of 2.5 % per °C","Width":"20.6 in (522 mm)","title":"ATV350U15N4W","Height":"12.2 in (310 mm)","Supply":"Internal supply for logic inputs 24 V DC","Marking":"CE UL CULus IEC UKCA","Variant":"Basic version","Category":"US1CP4B22182","Isolation":"Between power and control terminals","Standards":"IEC 61800-5-1 IEC 61800-3 UL 508C IEC 61800-3 environments 1 category C2 IEC 61800-3 environments 2 category C3 IEC 60721-3 IEC 61508 IEC 13849-1","EMC filter":"Class C2 EMC filter integrated EN 61508 32.8 ft (10 m) Class C2 EMC filter integrated EN 61800-5-1 32.8 ft (10 m) Class C2 EMC filter integrated EN 61800-5-2 32.8 ft (10 m) Class C2 EMC filter integrated IEC 60529 32.8 ft (10 m) Class C2 EMC filter integrated UL 50E 32.8 ft (10 m) Class C2 EMC filter integrated machinery directive 2006/42/EC 32.8 ft (10 m)","description":"variable speed drive, Altivar Machine ATV350, standard I/O, STO, 1.5kW, 2hp, 400 to 480V, IP66","Line current":"6.3 A 400...480 V conveying applications)","Mounting Mode":"Wall mounted","Apparent power":"2.5 kVA 400...480 V conveying applications)","Connector type":"M12 I/O on base)EtherCAT M12 I/O on base)EtherNet/IP M12 I/O on base)Modbus TCP M12 I/O on base)PROFINET","Motor power kW":"1.5 kW conveying applications","Output Current":"6.3 A","Output voltage":"460 V","Product Weight":"7.05 lb(US) (3.2 kg)","Protection type":"Line supply phase loss drive Motor phase loss motor Line supply overvoltage and undervoltage drive Overheating protection drive Overload motor With PTC probes motor Short-circuit between motor phases drive Overcurrent between output phases and earth drive","Safety Function":"STO (safe torque off)","Type of cooling":"AN (air natural)","lifecycle_stage":"current","Local signalling":"LEDs (red) for status","Method of access":"IO scanner","Output frequency":"1...599 Hz","Pollution degree":"2","Range of Product":"Altivar Machine ATV350","Supply frequency":"45...65 Hz","Device short name":"ATV350","Relative humidity":"5...95 % without condensation EN/IEC 60068-2-3","Operating altitude":"3280.84 ft (1000 m) with current derating of 0.5 % per additional 100 m","Operating position":"Horizontal","Physical interface":"2 Ethernet ports 100BASE-FX EtherNet/IP","Discrete input type":"discrete input, 12 V DC","Input compatibility":"1 incremental encoder (24 V)","Product destination":"Asynchronous motors Synchronous motors","Switching frequency":"2...16 kHz with current derating of 0.5 % per additional 100 m","Discrete input logic":"Programmable digital input digital I/O, 0...0.8 V, 11...24 V","Frequency resolution":"Motor 0.1 Hz","Vibration resistance":"1 mm (f= 5...13 Hz) conforming to DNVGL-GC-0339 0.7 gn (f= 13...100 Hz) conforming to DNVGL-GC-0339","Discrete input number":"4","Electrical connection":"2 connectors","Nbr. of units in pkg.":"1","IP degree of protection":"IP66 conforming to EN 61508 IP66 conforming to EN 61800-5-1 IP66 conforming to EN 61800-5-2 IP66 conforming to IEC 60529 IP66 conforming to UL 50E IP66 conforming to machinery directive 2006/42/EC","Motor slip compensation":"Adjustable","Number Of Preset Speeds":"16 preset speeds","Continuous output current":"6.3 A 2...16 kHz conveying applications","Maximum transient current":"12.6 A 3 s conveying applications) 9.4 A 60 s conveying applications)","Product or Component Type":"Variable speed drive","[Us] rated supply voltage":"400...480 V +/-5 %","Maximum Horse Power Rating":"2 hp heavy duty","Communication Port Protocol":"EtherNet/IP EtherCAT IO-Link Modbus TCP PROFINET","Nominal switching frequency":"12 kHz","Product Specific Application":"Material handling","Synchronous motor control profile":"Permanent magnet control in open loop Permanent magnet control in close loop","Asynchronous motor control profile":"U/F vector control Sensorless vector control (SVC) Energy saving control Closed-loop control with encoder","Acceleration and deceleration ramps":"2 customized adjustable ramps for acceleration and deceleration","Ambient Air Temperature for Storage":"-22...140 °F (-30...60 °C)","Ambient air temperature for operation":"-22...140 °F (-30...60 °C) (with current derating of 2.5 % per °C above 40 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/762d36a4fced1e447f0465dae7d5bb18.pdf","sourceUrl":"https://www.se.com/us/en/product/ATV350U15N4W/variable-speed-drive-altivar-machine-atv350-standard-i-o-sto-1-5kw-2hp-400-to-480v-ip66/"},"ai":{"faq":[{"question":"What safety functions does it include?","answer":"The drive includes STO (Safe Torque Off) as a standard safety function, compliant with IEC 61508 and IEC 13849-1."},{"question":"What compliance markings does it carry?","answer":"It carries CE, UL, CULus, IEC, and UKCA markings, and complies with IEC 61800-5-1, IEC 61800-3, UL 508C, and other relevant standards."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV350U15N4W","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV350U15N4W when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}