{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV350U22N4FS","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV350U22N4FS","canonicalUrl":"https://aoctrl.com/schneider/ATV350U22N4FS","factsUrl":"https://aoctrl.com/api/mcp/products/ATV350U22N4FS","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Machine ATV350, ATV350U22N4FS, 2.2 kW, 8.5 A output, 400-480 V 3-phase, wall-mounted drive with integrated STO safety and Class C2 EMC filter.","salesMarkdown":"The ATV350U22N4FS is a 2.2 kW Altivar Machine drive rated 8.5 A output at 460 V, 3-phase input. It handles both asynchronous and synchronous motors across a 1-599 Hz output frequency range. Switching frequency is adjustable from 2 to 16 kHz, with current derating of 0.5 % per 100 m above 1000 m altitude. Built-in STO (safe torque off) meets SIL 3 / PL e per IEC 61800-5-2 and IEC 61508, so you can skip an external safety relay for the drive axis. The integrated Class C2 EMC filter covers conducted emissions for first-environment (residential) installations up to 10 m cable runs. Communication options include EtherNet/IP, EtherCAT, Modbus TCP, and PROFINET via M12 connectors on the base. The internal 24 V DC supply powers the logic inputs directly, no separate PSU needed for the control side. Wall-mounted unit, dimensions 12.2 x 20.6 x 9.2 in (H x W x D). Natural air cooling (AN) — no fan to fail, but keep the gland plate clear for convection. Pollution degree 2 environment, horizontal operating position. Line supply phase-loss, motor phase-loss, overvoltage, undervoltage, overheating, and short-circuit protections are all onboard. Motor overload protection with PTC probes is supported.","metaTitle":"Schneider Electric ATV350U22N4FS Altivar Machine Drive, 2.2","metaDescription":"ATV350U22N4FS is an active Altivar Machine drive rated 2.2 kW / 8.5 A, 400-480 V 3-phase, with integrated STO safety and Class C2 EMC filter. Sourced to order against an RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"9.2 in (233 mm)","Phase":"3 phase with current derating of 2.5 % per °C","Width":"20.6 in (522 mm)","title":"ATV350U22N4FS","Height":"12.2 in (310 mm)","Supply":"Internal supply for logic inputs 24 V DC","Marking":"CE UL CULus IEC UKCA","Variant":"Safety","Category":"US1CP4B22182","Isolation":"Between power and control terminals","Standards":"IEC 61800-5-1 IEC 61800-3 UL 508C IEC 61800-3 environments 1 category C2 IEC 61800-3 environments 2 category C3 IEC 60721-3 IEC 61508 IEC 13849-1","EMC filter":"Class C2 EMC filter integrated EN 61508 32.8 ft (10 m) Class C2 EMC filter integrated EN 61800-5-1 32.8 ft (10 m) Class C2 EMC filter integrated EN 61800-5-2 32.8 ft (10 m) Class C2 EMC filter integrated IEC 60529 32.8 ft (10 m) Class C2 EMC filter integrated UL 50E 32.8 ft (10 m) Class C2 EMC filter integrated machinery directive 2006/42/EC 32.8 ft (10 m)","description":"variable speed drive, Altivar Machine ATV350, application I/O, fieldbus safety, 2.2kW, 3hp, 400 to 480V, IP54","Line current":"8.5 A 400...480 V conveying applications)","Mounting Mode":"Wall mounted","Apparent power":"3.5 kVA 400...480 V conveying applications)","Connector type":"M12 I/O on base)EtherCAT M12 I/O on base)EtherNet/IP M12 I/O on base)Modbus TCP M12 I/O on base)PROFINET","Motor power kW":"2.2 kW conveying applications","Output Current":"8.5 A","Output voltage":"460 V","Product Weight":"7.05 lb(US) (3.2 kg)","Protection type":"Line supply phase loss drive Motor phase loss motor Line supply overvoltage and undervoltage drive Overheating protection drive Overload motor With PTC probes motor Short-circuit between motor phases drive Overcurrent between output phases and earth drive","Safety Function":"STO (safe torque off)","Type of cooling":"AN (air natural)","lifecycle_stage":"current","Local signalling":"LEDs (red) for status","Method of access":"IO scanner","Output frequency":"1...599 Hz","Pollution degree":"2","Range of Product":"Altivar Machine ATV350","Supply frequency":"45...65 Hz","Device short name":"ATV350","Relative humidity":"5...95 % without condensation EN/IEC 60068-2-3","Operating altitude":"3280.84 ft (1000 m) with current derating of 0.5 % per additional 100 m","Operating position":"Horizontal","Physical interface":"2 Ethernet ports 100BASE-FX EtherNet/IP","Discrete input type":"discrete input, 12 V DC","Input compatibility":"1 incremental encoder (24 V)","Product destination":"Asynchronous motors Synchronous motors","Switching frequency":"2...16 kHz with current derating of 0.5 % per additional 100 m","Discrete input logic":"Programmable digital input digital I/O, 0...0.8 V, 11...24 V","Frequency resolution":"Motor 0.1 Hz","Vibration resistance":"1 mm (f= 5...13 Hz) conforming to DNVGL-GC-0339 0.7 gn (f= 13...100 Hz) conforming to DNVGL-GC-0339","Discrete input number":"8","Electrical connection":"2 connectors","Nbr. of units in pkg.":"1","IP degree of protection":"IP54 conforming to EN 61508 IP54 conforming to EN 61800-5-1 IP54 conforming to EN 61800-5-2 IP54 conforming to IEC 60529 IP54 conforming to UL 50E IP54 conforming to machinery directive 2006/42/EC","Motor slip compensation":"Adjustable","Number Of Preset Speeds":"16 preset speeds","Continuous output current":"8.6 A 2...16 kHz conveying applications","Maximum transient current":"17.0 A 3 s conveying applications) 12.7 A 60 s conveying applications)","Product or Component Type":"Variable speed drive","[Us] rated supply voltage":"400...500 V +/-5 %","Maximum Horse Power Rating":"3 hp heavy duty","Communication Port Protocol":"EtherNet/IP EtherCAT IO-Link Modbus TCP PROFINET","Nominal switching frequency":"12 kHz","Product Specific Application":"Material handling","Synchronous motor control profile":"Permanent magnet control in open loop Permanent magnet control in close loop","Asynchronous motor control profile":"U/F vector control Sensorless vector control (SVC) Energy saving control Closed-loop control with encoder","Acceleration and deceleration ramps":"2 customized adjustable ramps for acceleration and deceleration","Ambient Air Temperature for Storage":"-22...140 °F (-30...60 °C)","Ambient air temperature for operation":"-22...140 °F (-30...60 °C) (with current derating of 2.5 % per °C above 40 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4ae9eaec8c22490350fb9feb8f2bf525.pdf","sourceUrl":"https://www.se.com/us/en/product/ATV350U22N4FS/variable-speed-drive-altivar-machine-atv350-application-i-o-fieldbus-safety-2-2kw-3hp-400-to-480v-ip54/"},"ai":{"faq":[{"question":"What safety functions does the ATV350U22N4FS include?","answer":"It includes STO (safe torque off) as standard, compliant with IEC 61800-5-2 and IEC 61508 for SIL 3 / PL e applications."},{"question":"What compliance markings and standards does the ATV350U22N4FS carry?","answer":"It carries CE, UL, CULus, IEC, and UKCA markings. It complies with IEC 61800-5-1, IEC 61800-3 (environments 1 category C2 and 2 category C3), UL 508C, IEC 60721-3, IEC 61508, and IEC 13849-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV350U22N4FS","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV350U22N4FS when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}