{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV6000C150A4242NA3","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV6000C150A4242NA3","canonicalUrl":"https://aoctrl.com/schneider/ATV6000C150A4242NA3","factsUrl":"https://aoctrl.com/api/mcp/products/ATV6000C150A4242NA3","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV6000, 1200 kW normal duty / 960 kW heavy duty medium voltage drive, 24-pulse diode rectifier, floor-standing enclosure.","salesMarkdown":"## Medium voltage drive for synchronous, permanent magnet, and asynchronous motors The Schneider Electric ATV6000C150A4242NA3 is an Altivar Process ATV6000 medium voltage drive rated for 1200 kW normal duty and 960 kW heavy duty, covering synchronous, permanent magnet, and asynchronous motors. Its 24-pulse diode rectifier input keeps total harmonic current distortion below 3% per IEEE 519-1992, which avoids the need for external harmonic filters on most grids. The drive ships in a floor-standing enclosure measuring 3760 mm wide by 1400 mm deep by 2751 mm high, with cable entry from the bottom. ## Duty ratings and line current Line current draw is 166 A under heavy duty and 208 A under normal duty, so the supply transformer and upstream protection must be sized for the normal-duty figure even if the motor is derated. Power losses run 41.8 kW heavy duty and 52.2 kW normal duty — that heat lands in the room, not just the cabinet, so ventilation planning starts with these numbers. ## Control and communication The drive includes a 10-inch LCD touchscreen HMI for local commissioning and monitoring. Communication slots accept Profibus DP V1, PROFINET, DeviceNet, CANopen, or EtherCAT modules in slot A; encoder feedback modules (digital 5/12 V, analog, resolver, HTL) go in slot B. Two RJ45 ports on the control block handle Ethernet IP and Modbus TCP; a third RJ45 handles Modbus serial. Eight programmable digital inputs (24 V DC, two configurable as pulse inputs up to 30 kHz) and configurable analog I/O cover the control interface. ## Protection and compliance Protection covers line supply overvoltage/undervoltage/phase loss, DC bus overvoltage, transformer thermal overload, cabinet overheating, overcurrent, overload, short-circuit, IGBT cell thermal, motor thermal, motor phase break, motor earth fault, control circuit break, and fan monitoring. The drive carries CE and EAC marking, complies with IEC 61800-3 (EMC category C3 control, C4 power), IEC 61800-4, IEC 61800-5-1, IEC 60529, IEEE 519:1992, and EN/IEC 60076. Pollution degree 2 per IEC 61800-5-1.","metaTitle":"Schneider Electric ATV6000C150A4242NA3 Altivar Process ATV60","metaDescription":"Schneider Electric ATV6000C150A4242NA3 medium voltage drive, 1200 kW normal duty / 960 kW heavy duty, 24-pulse rectifier, THDI <3%. Active lifecycle, sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"1400.0 mm","Width":"3760.0 mm","Height":"2751.0 mm","Supply":"Internal supply for digital inputs and PoE 24 V DC 21...27 V, Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, External supply for digital inputs 24 V DC 19...30 V External supply for control circuit 100...240 V AC 47...63 Hz External supply for control circuit 120...370 V DC +/- 10 % 1 kVA Auxiliary power supply 230 V AC +/- 10 % External supply for cooling fan 400 V AC +/- 10 % 5 kVA","Marking":"CE EAC","Isolation":"Electrical between power and control","Standards":"IEC 61800-3 EN/IEC 61800-4 IEC 61800-5-1 IEC 60529 IEEE 519:1992 EN/IEC 60076","EMC filter":"Integrated conforming to IEC 61800-3 category C3 control Integrated conforming to IEC 61800-3 category C4 power","Input type":"24 pulse diode rectifier bridge","Cable Entry":"Bottom","Noise level":"80 dB","Option card":"Slot A: communication module for Profibus DP V1 Slot A: communication module for PROFINET Slot A: communication module for DeviceNet Slot A: communication module for CANopen daisy chain RJ45 Slot A: communication module for CANopen SUB-D 9 Slot A: communication module for CANopen screw terminals Slot A: communication module for EtherCAT Slot B: 5/12 V digital encoder interface module Slot B: analog encoder interface module Slot B: resolver encoder interface module Slot B: HTL encoder interface module Slot A/slot B: digital and analog I/O extension module Slot A/slot B: output relay extension module","Output type":"IGBT inverter cells multilevel PWM","Display type":"10 inch LCD touch screen multi-language","Line current":"166 A heavy duty 208 A normal duty","Maximum THDI":"<3 % conforming to IEEE 519-1992","Power factor":"96","Power losses":"52.2 kW normal duty 41.8 kW heavy duty","Apparent power":"1500 kVA","Assembly style":"In floor-standing enclosure","Connector type":"2 RJ45 (on the control block) for Ethernet IP/Modbus TCP 1 RJ45 (on the control block) for Modbus serial","Motor power kW":"1200 kW for normal duty 960 kW for heavy duty","Output voltage":"<= power supply voltage","Protection type":"Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overvoltages on the DC bus: drive Thermal overload for transformer: drive Cabinet overheating: drive Overcurrent: drive Overload: drive Short-circuit protection: drive IGBT for each cell: drive Thermal protection: motor Motor phase break: motor Motor earth fault: motor Break on the control circuit: drive Fan monitoring: drive","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to IEC 61800-5-1","Range of product":"Altivar Process ATV6000","Supply frequency":"50 Hz +/- 5 %","Device short name":"ATV6000","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Relay output type":"Configurable relay logic R1: fault relay NO/NC Configurable relay logic R2: sequence relay NO Configurable relay logic R3: sequence relay NO","Operating altitude":"1000...2000 m with derating factor","Provided equipment":"Power cells Phase-shifting transformer Cooling fans Human machine interface Medium voltage arrestors Enclosure Plinth","Analogue input type":"configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution: 12 bits configurable current: 0...20 mA, impedance: 250 Ohm, resolution: 12 bits","Colour of enclosure":"Light grey (RAL 7035)","Discrete input type":"DI1...DI8 programmable, 24 V DC ( DI7, DI8 programmable as pulse input: 0...30 kHz, 24 V DC ( POEA, POEB PWM output enable, 24 V DC (<= 30 V), impedance: > 2.2 kOhm","Product destination":"Synchronous motors Permanent magnet motors Asynchronous motors","Relay output number":"3","Analogue output type":"Configurable voltage: 0...10 V DC impedance 470 Ohm, resolution 10 bits Configurable current: 0...20 mA impedance 500 Ohm, resolution 10 bits","Discrete output type":"Logic output <= 30 V DC 100 mA","Frequency resolution":"0.01 Hz","Overvoltage category":"II conforming to IEC 61800-5-1 motor side III conforming to IEC 61800-5-1 line side III conforming to IEC 61800-5-1 low voltage connections","Prospective line Isc":"31.5 kA for 150 ms","Discrete input number":"10","Volume of cooling air":"13538 m3/h","Analogue output number":"2","Discrete output number":"2","Energy efficiency ratio":"0.985 inverter 0.96 total drive including transformer","IP degree of protection":"IP31 conforming to IEC 60529","Network number of phases":"3 phases","Continuous output current":"160 A heavy duty 199 A normal duty","Maximum transient current":"300 A during 3 s (heavy duty) 299 A during 3 s (normal duty)","Product or component type":"Medium voltage variable speed drive","[Us] rated supply voltage":"4.16 kV +/- 10 %","Communication port protocol":"Ethernet IP/Modbus TCP","Environmental characteristic":"3K3 conforming to IEC 60721-3-3 3B1 conforming to IEC 60721-3-3 3C2 conforming to IEC 60721-3-3 3S1 conforming to IEC 60721-3-3 3M1 conforming to IEC 60721-3-3","Product specific application":"Process and utilities","Speed drive output frequency":"0.1...120 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Synchronous motor control profile":"Permanent magnet control in open loop Permanent magnet control in close loop Line start permanent magnet motor","Asynchronous motor control profile":"Closed loop vector control U/F vector control Energy saving control Vector control with slip compensation in open loop","Ambient air temperature for storage":"0...50 °C","Permissible temporary current boost":"1.2 x In during 60 s (normal duty) 1.5 x In during 3 s (normal duty) 1.5 x In during 60 s (heavy duty) 1.8 x In during 3 s (heavy duty)","Ambient air temperature for operation":"0...40 °C 40...50 °C with derating factor -25...70 °C during transport"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/be/en/product/ATV6000C150A4242NA3/medium-voltage-variable-speed-drive-atv6000-4-16-kv-1500-kva/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ATV6000C150A4242NA3/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this drive?","answer":"Rated 1200 kW normal duty / 960 kW heavy duty, line current 208 A normal / 166 A heavy, with a 24-pulse rectifier keeping THDI below 3%."},{"question":"What compliance documentation is available?","answer":"The drive carries CE and EAC marking and complies with IEC 61800-3, IEC 61800-4, IEC 61800-5-1, IEC 60529, IEEE 519:1992, and EN/IEC 60076."},{"question":"What are the physical dimensions of the enclosure?","answer":"The floor-standing enclosure measures 3760 mm wide by 1400 mm deep by 2751 mm high."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV6000C150A4242NA3","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV6000C150A4242NA3 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}