{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV6000C150A4242ND","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV6000C150A4242ND","canonicalUrl":"https://aoctrl.com/schneider/ATV6000C150A4242ND","factsUrl":"https://aoctrl.com/api/mcp/products/ATV6000C150A4242ND","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV6000, ATV6000C150A4242ND AC Drive (VFD) 480V, 1200 kW normal duty / 960 kW heavy duty, 3-phase, 1500 kVA, floor-standing enclosure.","salesMarkdown":"## Motor power and harmonic performance The ATV6000C150A4242ND: Rated 1200 kW normal duty and 960 kW heavy duty for asynchronous, synchronous, and permanent magnet motors — the heavy-duty figure governs continuous rating on pump, fan, or compressor loads where the drive runs at full nameplate. The 24-pulse diode rectifier input keeps total harmonic current distortion below 3 % per IEEE 519-1992, which means no external harmonic filter for most plant distribution systems — the drive itself cleans the line. ## Physical footprint and what ships with it Floor-standing enclosure, 108.3 in high × 148.03 in wide × 55.1 in deep — this is a dedicated drive room or large MCC footprint, not a wall-mount unit. Plan for forklift access and bottom cable entry. Ships with the phase-shifting transformer, power cells, cooling fans, plinth, and a 10-inch LCD touchscreen HMI — the drive arrives as a complete system, not a bare chassis. The 24-pulse topology and integrated transformer make this a specialized medium-voltage drive; availability is quoted to order against the BOM quantity through independent distribution. Carries cULus, CE, and UKCA markings with compliance to IEC 61800-3, IEC 61800-5-1, and UL 347A — accepted in North American, European, and UK industrial installations without additional certification work.","metaTitle":"Schneider ATV6000C150A4242ND AC Drive, 1200 kW, 3-phase","metaDescription":"Schneider Electric ATV6000C150A4242ND Altivar Process AC drive, 1200 kW normal duty, 3-phase, 480V. cULus, CE, UKCA. Current production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"55.1 in (1400.0 mm)","Phase":"3 phase","Width":"148.03 in (3760.0 mm)","title":"ATV6000C150A4242ND","Height":"108.3 in (2751.0 mm)","Supply":"Internal supply for digital inputs and PoE 24 V DC 21...27 V, Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, External supply for digital inputs 24 V DC 19...30 V External supply for control circuit 100...240 V AC 47...63 Hz External supply for control circuit 120...370 V DC +/- 10 % 1 kVA Auxiliary power supply 230 V AC +/- 10 % External supply for cooling fan 400 V AC +/- 10 % 5 kVA","Marking":"CULus CE UKCA","Isolation":"Electrical between power and control","Standards":"IEC 61800-3 EN/IEC 61800-4 IEC 61800-5-1 IEC 60529 IEEE 519:1992 EN/IEC 60076 UL 347A","EMC filter":"Integrated IEC 61800-3 category C3 control Integrated IEC 61800-3 category C4 Power","Input type":"24 pulse diode rectifier bridge","Cable Entry":"Bottom","Noise level":"80 dB","Option card":"Slot A communication module Profibus DP V1 Slot A communication module PROFINET Slot A communication module DeviceNet Slot A communication module CANopen daisy chain RJ45 Slot A communication module CANopen SUB-D 9 Slot A communication module CANopen screw terminals Slot A communication module EtherCAT Slot B 5/12 V digital encoder interface module Slot B analog encoder interface module Slot B resolver encoder interface module Slot B HTL encoder interface module Slot A/slot B digital and analog I/O extension module Slot A/slot B output relay extension module","Output type":"IGBT inverter cells multilevel PWM","description":"Medium Voltage Variable Speed Drive ATV6000, 4.16 kV, 1609 hp, UL certification","Display type":"10 inch LCD touch screen multi-language","Line current":"166 A heavy duty 208 A normal duty","Maximum THDI":"<3 % IEEE 519-1992","Power factor":"96","Power losses":"52.2 kW normal duty 41.8 kW heavy duty","Apparent power":"1500 kVA","Assembly style":"In floor-standing enclosure","Connector type":"2 RJ45 on the control block)Ethernet IP/Modbus TCP 1 RJ45 on the control block)Modbus serial","Motor power kW":"1200 kW normal duty 960 kW heavy duty","Output voltage":"<= power supply voltage","Protection type":"Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overvoltages on the DC bus drive Thermal overload for transformer drive Cabinet overheating drive Overcurrent drive Overload drive Short-circuit protection drive IGBT for each cell drive Thermal protection motor Motor phase break motor Motor earth fault motor Break on the control circuit drive Fan monitoring drive","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 IEC 61800-5-1","Range of Product":"Altivar Process ATV6000","Supply frequency":"50 Hz +/- 5 %","Device short name":"ATV6000","Relative humidity":"5...95 % without condensation IEC 60068-2-3","Relay output type":"Configurable relay logic R1 fault relay NO/NC Configurable relay logic R2 sequence relay NO Configurable relay logic R3 sequence relay NO","Operating altitude":"3280.84...6561.68 ft (1000...2000 m) with derating factor","Provided Equipment":"Plinth Cooling fans Enclosure Phase-shifting transformer Power cells Medium voltage arrestors Human machine interface","Analogue input type":"configurable voltage 0...10 V DC 30 kOhm 12 bits configurable current 0...20 mA 250 Ohm 12 bits","Colour of enclosure":"Light grey RAL 7035)","Discrete input type":"DI1...DI8 programmable, 24 V DC DI7, DI8 programmable as pulse input 0...30 kHz, 24 V DC POEA, POEB PWM output enable, 24 V DC 2.2 kOhm","Product destination":"Synchronous motors Permanent magnet motors Asynchronous motors","Relay output number":"3","Analogue output type":"Configurable voltage 0...10 V DC 470 Ohm 10 bits Configurable current 0...20 mA 500 Ohm 10 bits","Discrete output type":"Logic output <= 30 V DC 100 mA","Frequency resolution":"0.01 Hz","Overvoltage category":"II IEC 61800-5-1 motor side III IEC 61800-5-1 line side III IEC 61800-5-1 low voltage connections","Prospective line Isc":"31.5 kA 150 ms","Discrete input number":"10","Volume of cooling air":"3519468.8 Gal/hr(US) (13322.4 m3/h)","Analogue output number":"2","Discrete output number":"2","Energy efficiency ratio":"0.985 inverter 0.96 total drive including transformer","IP degree of protection":"IP31 conforming to IEC 60529","Continuous output current":"160 A heavy duty 199 A normal duty","Maximum transient current":"300 A 3 s heavy duty) 299 A 3 s normal duty)","Product or Component Type":"Medium voltage variable speed drive","[Us] rated supply voltage":"4.16 kV +/- 10 %","Maximum Horse Power Rating":"1287.0 hp heavy duty 1609.0 hp normal duty","Communication Port Protocol":"Ethernet IP/Modbus TCP","Environmental characteristic":"3K3 conforming to IEC 60721-3-3 3B1 conforming to IEC 60721-3-3 3C2 conforming to IEC 60721-3-3 3S1 conforming to IEC 60721-3-3 3M1 conforming to IEC 60721-3-3","Product Specific Application":"Process and utilities","Speed drive output frequency":"0.1...120 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Synchronous motor control profile":"Permanent magnet control in open loop Permanent magnet control in close loop Line start permanent magnet motor","Asynchronous motor control profile":"Closed loop vector control U/F vector control Energy saving control Vector control with slip compensation in open loop","Ambient Air Temperature for Storage":"32...122 °F (0...50 °C)","Permissible temporary current boost":"1.2 x In 60 s normal duty) 1.5 x In 3 s normal duty) 1.5 x In 60 s heavy duty) 1.8 x In 3 s heavy duty)","Ambient air temperature for operation":"32...104 °F (0...40 °C) 104...122 °F (40...50 °C) with derating factor -13...158 °F (-25...70 °C) during transport"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/us/en/product/download-pdf/ATV6000C150A4242ND?filename=Schneider+Electric_Altivar-Process-ATV6000_ATV6000C150A4242ND.pdf', 'path_name': '6242c7673665ffdb339d1282983abdf2.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/6242c7673665ffdb339d1282983abdf2.pdf', 'status': 1}","sourceUrl":"https://www.se.com/us/en/product/ATV6000C150A4242ND/medium-voltage-variable-speed-drive-atv6000-4-16-kv-1609-hp-ul-certification/"},"ai":{"faq":[{"question":"What motor types does ATV6000C150A4242ND support?","answer":"It drives asynchronous motors, permanent magnet synchronous motors, and standard synchronous motors — covers the three common industrial AC motor families."},{"question":"What is the harmonic performance of this drive?","answer":"Total harmonic current distortion is below 3 % per IEEE 519-1992, achieved by the 24-pulse diode rectifier input without external filtering."},{"question":"What compliance documentation does Schneider provide for ATV6000C150A4242ND?","answer":"The drive carries cULus, CE, and UKCA markings and complies with IEC 61800-3 (EMC), IEC 61800-5-1 (safety), and UL 347A (medium-voltage drives)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV6000C150A4242ND","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV6000C150A4242ND when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}