{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV6000C213A6060NA3","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV6000C213A6060NA3","canonicalUrl":"https://aoctrl.com/schneider/ATV6000C213A6060NA3","factsUrl":"https://aoctrl.com/api/mcp/products/ATV6000C213A6060NA3","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV6000, ATV6000C213A6060NA3, medium-voltage variable speed drive, 1700 kW normal duty, 30-pulse rectifier, floor-standing enclosure.","salesMarkdown":"The Schneider Electric ATV6000C213A6060NA3 is a medium-voltage variable speed drive from the Altivar Process ATV6000 series, built as a floor-standing enclosure. It drives synchronous, asynchronous, and permanent magnet motors up to 1700 kW under normal duty, or 1390 kW under heavy duty. The 30-pulse diode rectifier input keeps total harmonic current distortion below 3 % per IEEE 519-1992, which avoids the need for external harmonic filters on most utility grids. Line current is rated 167 A for heavy duty and 205 A for normal duty. The normal-duty figure governs the continuous motor load; the heavy-duty figure applies when the drive must deliver overload torque for a defined period. Use the normal-duty number for the main feeder sizing. Apparent power is 2130 kVA, which sets the transformer and upstream breaker rating. Power losses run 73.9 kW at normal duty and 60.4 kW at heavy duty — figure those into the room's cooling capacity. The enclosure measures 4660 mm wide by 1500 mm deep by 2751 mm high. That footprint determines floor-space allocation and the swing clearance for the front doors. Cable entry is at the bottom. ## Supply and control wiring The control circuit accepts 100...240 V AC, 47...63 Hz, or 120...370 V DC. The auxiliary power supply runs on 230 V AC, and the cooling fan supply is 400 V AC. Digital inputs are 24 V DC, with an internal supply available for the reference potentiometer (10.5 V DC). Two RJ45 ports on the control block handle Ethernet IP and Modbus TCP; a third RJ45 handles Modbus serial. Slot A accepts communication modules for Profibus DP V1, PROFINET, DeviceNet, CANopen, or EtherCAT. Slot B accepts encoder interface modules (5/12 V digital, analog, resolver, HTL). Both slots can also take digital/analog I/O extension or output relay extension modules. ## Protection and compliance The drive monitors line supply overvoltage, undervoltage, phase loss, DC bus overvoltage, transformer thermal overload, cabinet overheating, overcurrent, overload, short-circuit, IGBT faults, motor thermal protection, motor phase break, motor earth fault, control circuit break, and fan status. That covers nearly every failure mode a medium-voltage installation will see. Integrated EMC filter meets IEC 61800-3 category C3 for the control section and category C4 for the power section. Standards compliance includes IEC 61800-3, IEC 61800-4, IEC 61800-5-1, IEC 60529, IEEE 519:1992, and EN/IEC 60076. Markings are EAC and CE.","metaTitle":"Schneider ATV6000C213A6060NA3 Altivar Process, 1700 kW VFD","metaDescription":"Schneider ATV6000C213A6060NA3 medium-voltage VFD, 1700 kW normal duty, 30-pulse rectifier, <3% THDI. Current lifecycle stage. Sourced to order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"1500.0 mm","Width":"4660.0 mm","Height":"2751.0 mm","Supply":"Internal supply for digital inputs and PoE 24 V DC 21...27 V, Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, External supply for digital inputs 24 V DC 19...30 V External supply for control circuit 100...240 V AC 47...63 Hz External supply for control circuit 120...370 V DC +/- 10 % 1 kVA Auxiliary power supply 230 V AC +/- 10 % External supply for cooling fan 400 V AC +/- 10 % 7 kVA","Marking":"EAC CE","Isolation":"Electrical between power and control","Standards":"IEC 61800-3 EN/IEC 61800-4 IEC 61800-5-1 IEC 60529 IEEE 519:1992 EN/IEC 60076","EMC filter":"Integrated conforming to IEC 61800-3 category C3 control Integrated conforming to IEC 61800-3 category C4 power","Input type":"30 pulse diode rectifier bridge","Cable Entry":"Bottom","Noise level":"80 dB","Option card":"Slot A: communication module for Profibus DP V1 Slot A: communication module for PROFINET Slot A: communication module for DeviceNet Slot A: communication module for CANopen daisy chain RJ45 Slot A: communication module for CANopen SUB-D 9 Slot A: communication module for CANopen screw terminals Slot A: communication module for EtherCAT Slot B: 5/12 V digital encoder interface module Slot B: analog encoder interface module Slot B: resolver encoder interface module Slot B: HTL encoder interface module Slot A/slot B: digital and analog I/O extension module Slot A/slot B: output relay extension module","Output type":"IGBT inverter cells multilevel PWM","Display type":"10 inch LCD touch screen multi-language","Line current":"167 A heavy duty 205 A normal duty","Maximum THDI":"<3 % conforming to IEEE 519-1992","Power factor":"96","Power losses":"73.9 kW normal duty 60.4 kW heavy duty","Apparent power":"2130 kVA","Assembly style":"In floor-standing enclosure","Connector type":"2 RJ45 (on the control block) for Ethernet IP/Modbus TCP 1 RJ45 (on the control block) for Modbus serial","Motor power kW":"1700 kW for normal duty 1390 kW for heavy duty","Output voltage":"<= power supply voltage","Protection type":"Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overvoltages on the DC bus: drive Thermal overload for transformer: drive Cabinet overheating: drive Overcurrent: drive Overload: drive Short-circuit protection: drive IGBT for each cell: drive Thermal protection: motor Motor phase break: motor Motor earth fault: motor Break on the control circuit: drive Fan monitoring: drive","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to IEC 61800-5-1","Range of product":"Altivar Process ATV6000","Supply frequency":"50 Hz +/- 5 %","Device short name":"ATV6000","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Relay output type":"Configurable relay logic R1: fault relay NO/NC Configurable relay logic R2: sequence relay NO Configurable relay logic R3: sequence relay NO","Operating altitude":"1000...2000 m with derating factor","Provided equipment":"Power cells Phase-shifting transformer Cooling fans Human machine interface Medium voltage arrestors Enclosure Plinth","Analogue input type":"configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution: 12 bits configurable current: 0...20 mA, impedance: 250 Ohm, resolution: 12 bits","Colour of enclosure":"Light grey (RAL 7035)","Discrete input type":"DI1...DI8 programmable, 24 V DC ( DI7, DI8 programmable as pulse input: 0...30 kHz, 24 V DC ( POEA, POEB PWM output enable, 24 V DC (<= 30 V), impedance: > 2.2 kOhm","Product destination":"Synchronous motors Asynchronous motors Permanent magnet motors","Relay output number":"3","Analogue output type":"Configurable voltage: 0...10 V DC impedance 470 Ohm, resolution 10 bits Configurable current: 0...20 mA impedance 500 Ohm, resolution 10 bits","Discrete output type":"Logic output <= 30 V DC 100 mA","Frequency resolution":"0.01 Hz","Overvoltage category":"II conforming to IEC 61800-5-1 motor side III conforming to IEC 61800-5-1 line side III conforming to IEC 61800-5-1 low voltage connections","Prospective line Isc":"31.5 kA for 150 ms","Discrete input number":"10","Volume of cooling air":"18912 m3/h","Analogue output number":"2","Discrete output number":"2","Energy efficiency ratio":"0.985 inverter 0.96 total drive including transformer","IP degree of protection":"IP31 conforming to IEC 60529","Network number of phases":"3 phases","Continuous output current":"160 A heavy duty 196 A normal duty","Maximum transient current":"300 A during 3 s (heavy duty) 294 A during 3 s (normal duty)","Product or component type":"Medium voltage variable speed drive","[Us] rated supply voltage":"6 kV +/- 10 %","Communication port protocol":"Ethernet IP/Modbus TCP","Environmental characteristic":"3K3 conforming to IEC 60721-3-3 3B1 conforming to IEC 60721-3-3 3C2 conforming to IEC 60721-3-3 3S1 conforming to IEC 60721-3-3 3M1 conforming to IEC 60721-3-3","Product specific application":"Process and utilities","Speed drive output frequency":"0.1...120 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Synchronous motor control profile":"Permanent magnet control in open loop Permanent magnet control in close loop Line start permanent magnet motor","Asynchronous motor control profile":"Closed loop vector control U/F vector control Energy saving control Vector control with slip compensation in open loop","Ambient air temperature for storage":"0...50 °C","Permissible temporary current boost":"1.2 x In during 60 s (normal duty) 1.5 x In during 3 s (normal duty) 1.5 x In during 60 s (heavy duty) 1.8 x In during 3 s (heavy duty)","Ambient air temperature for operation":"0...40 °C 40...50 °C with derating factor -25...70 °C during transport"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/be/en/product/ATV6000C213A6060NA3/medium-voltage-variable-speed-drive-atv6000-6-kv-2130-kva/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ATV6000C213A6060NA3/alternatives.json"},"ai":{"faq":[{"question":"What are the enclosure dimensions?","answer":"Width 4660 mm, depth 1500 mm, height 2751 mm. Cable entry is at the bottom."},{"question":"What motor types does this drive support?","answer":"It drives synchronous motors, asynchronous motors, and permanent magnet motors."},{"question":"What harmonic performance does the drive achieve?","answer":"Total harmonic current distortion is below 3 %, conforming to IEEE 519-1992, thanks to the 30-pulse rectifier input."},{"question":"What communication protocols are available?","answer":"The drive supports Ethernet IP, Modbus TCP, and Modbus serial via RJ45 ports. Slot A can host Profibus DP V1, PROFINET, DeviceNet, CANopen, or EtherCAT modules."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV6000C213A6060NA3","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV6000C213A6060NA3 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}