{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV6000C240A4242ND","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV6000C240A4242ND","canonicalUrl":"https://aoctrl.com/schneider/ATV6000C240A4242ND","factsUrl":"https://aoctrl.com/api/mcp/products/ATV6000C240A4242ND","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV6000, ATV6000C240A4242ND AC Drive (VFD) 480V, 1920 kW normal duty / 1540 kW heavy duty, 2400 kVA, 24-pulse diode rectifier, floor-standing enclosure.","salesMarkdown":"## Motor power and line current — normal vs heavy duty The ATV6000C240A4242ND: Rated 1920 kW normal duty and 1540 kW heavy duty, with line current 333 A normal / 267 A heavy duty. The heavy-duty figure governs continuous overload capability for high-torque loads like crushers or mills; the normal-duty rating applies when the load profile stays below the motor's service factor. ## 24-pulse rectifier — THDI <3% without external filtering The 24-pulse diode rectifier front end keeps total harmonic current distortion below 3% per IEEE 519-1992, so the drive meets utility power-quality limits without adding a separate harmonic filter. Power factor is 96%, which reduces the kVA draw from the upstream transformer. ## Regulatory acceptance — cULus, CE, UKCA Marked cULus, CE, and UKCA, with standards compliance to IEC 61800-3/-4/-5-1, IEC 60529, IEEE 519, and UL 347A. That covers North American and EU installation without a separate certification step — a practical advantage for a multinational project spec. ## Floor-standing enclosure — plan the substation footprint The drive ships in a floor-standing enclosure measuring 59.06 in deep, 199.2 in wide, and 108.3 in high. That footprint dictates the MCC room or substation layout — allow front and rear access clearance per the installation manual for cable entry and cooling airflow.","metaTitle":"Schneider ATV6000C240A4242ND AC Drive, 1920 kW, 2400 kVA","metaDescription":"Schneider Electric ATV6000C240A4242ND Altivar Process AC Drive, 1920 kW normal duty, 2400 kVA, 24-pulse rectifier, THDI <3%. Active production, sourced per RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"59.06 in (1500.0 mm)","Phase":"3 phase","Width":"199.2 in (5060.0 mm)","title":"ATV6000C240A4242ND","Height":"108.3 in (2751.0 mm)","Supply":"Internal supply for digital inputs and PoE 24 V DC 21...27 V, Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, External supply for digital inputs 24 V DC 19...30 V External supply for control circuit 100...240 V AC 47...63 Hz External supply for control circuit 120...370 V DC +/- 10 % 1 kVA Auxiliary power supply 230 V AC +/- 10 % External supply for cooling fan 400 V AC +/- 10 % 7 kVA","Marking":"CULus CE UKCA","Isolation":"Electrical between power and control","Standards":"IEC 61800-3 EN/IEC 61800-4 IEC 61800-5-1 IEC 60529 IEEE 519:1992 EN/IEC 60076 UL 347A","EMC filter":"Integrated IEC 61800-3 category C3 control Integrated IEC 61800-3 category C4 Power","Input type":"24 pulse diode rectifier bridge","Cable Entry":"Bottom","Noise level":"80 dB","Option card":"Slot A communication module Profibus DP V1 Slot A communication module PROFINET Slot A communication module DeviceNet Slot A communication module CANopen daisy chain RJ45 Slot A communication module CANopen SUB-D 9 Slot A communication module CANopen screw terminals Slot A communication module EtherCAT Slot B 5/12 V digital encoder interface module Slot B analog encoder interface module Slot B resolver encoder interface module Slot B HTL encoder interface module Slot A/slot B digital and analog I/O extension module Slot A/slot B output relay extension module","Output type":"IGBT inverter cells multilevel PWM","description":"Medium Voltage Variable Speed Drive ATV6000, 4.16 kV, 2574 hp, UL certification","Display type":"10 inch LCD touch screen multi-language","Line current":"333 A normal duty 267 A heavy duty","Maximum THDI":"<3 % IEEE 519-1992","Power factor":"96","Power losses":"83.5 kW normal duty 66.9 kW heavy duty","Apparent power":"2400 kVA","Assembly style":"In floor-standing enclosure","Connector type":"2 RJ45 on the control block)Ethernet IP/Modbus TCP 1 RJ45 on the control block)Modbus serial","Motor power kW":"1920 kW normal duty 1540 kW heavy duty","Output voltage":"<= power supply voltage","Protection type":"Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overvoltages on the DC bus drive Thermal overload for transformer drive Cabinet overheating drive Overcurrent drive Overload drive Short-circuit protection drive IGBT for each cell drive Thermal protection motor Motor phase break motor Motor earth fault motor Break on the control circuit drive Fan monitoring drive","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 IEC 61800-5-1","Range of Product":"Altivar Process ATV6000","Supply frequency":"50 Hz +/- 5 %","Device short name":"ATV6000","Relative humidity":"5...95 % without condensation IEC 60068-2-3","Relay output type":"Configurable relay logic R1 fault relay NO/NC Configurable relay logic R2 sequence relay NO Configurable relay logic R3 sequence relay NO","Operating altitude":"3280.84...6561.68 ft (1000...2000 m) with derating factor","Provided Equipment":"Medium voltage arrestors Phase-shifting transformer Plinth Human machine interface Enclosure Power cells Cooling fans","Analogue input type":"configurable voltage 0...10 V DC 30 kOhm 12 bits configurable current 0...20 mA 250 Ohm 12 bits","Colour of enclosure":"Light grey RAL 7035)","Discrete input type":"DI1...DI8 programmable, 24 V DC DI7, DI8 programmable as pulse input 0...30 kHz, 24 V DC POEA, POEB PWM output enable, 24 V DC 2.2 kOhm","Product destination":"Permanent magnet motors Synchronous motors Asynchronous motors","Relay output number":"3","Analogue output type":"Configurable voltage 0...10 V DC 470 Ohm 10 bits Configurable current 0...20 mA 500 Ohm 10 bits","Discrete output type":"Logic output <= 30 V DC 100 mA","Frequency resolution":"0.01 Hz","Overvoltage category":"II IEC 61800-5-1 motor side III IEC 61800-5-1 line side III IEC 61800-5-1 low voltage connections","Prospective line Isc":"31.5 kA 150 ms","Discrete input number":"10","Volume of cooling air":"4949193.5 Gal/hr(US) (18734.4 m3/h)","Analogue output number":"2","Discrete output number":"2","Energy efficiency ratio":"0.985 inverter 0.96 total drive including transformer","IP degree of protection":"IP31 conforming to IEC 60529","Continuous output current":"320 A normal duty 256 A heavy duty","Maximum transient current":"480 A 3 s normal duty) 480 A 3 s heavy duty)","Product or Component Type":"Medium voltage variable speed drive","[Us] rated supply voltage":"4.16 kV +/- 10 %","Maximum Horse Power Rating":"2065.0 hp heavy duty 2574.0 hp normal duty","Communication Port Protocol":"Ethernet IP/Modbus TCP","Environmental characteristic":"3K3 conforming to IEC 60721-3-3 3B1 conforming to IEC 60721-3-3 3C2 conforming to IEC 60721-3-3 3S1 conforming to IEC 60721-3-3 3M1 conforming to IEC 60721-3-3","Product Specific Application":"Process and utilities","Speed drive output frequency":"0.1...120 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Synchronous motor control profile":"Permanent magnet control in open loop Permanent magnet control in close loop Line start permanent magnet motor","Asynchronous motor control profile":"Closed loop vector control U/F vector control Energy saving control Vector control with slip compensation in open loop","Ambient Air Temperature for Storage":"32...122 °F (0...50 °C)","Permissible temporary current boost":"1.2 x In 60 s normal duty) 1.5 x In 3 s normal duty) 1.5 x In 60 s heavy duty) 1.8 x In 3 s heavy duty)","Ambient air temperature for operation":"32...104 °F (0...40 °C) 104...122 °F (40...50 °C) with derating factor -13...158 °F (-25...70 °C) during transport"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/us/en/product/download-pdf/ATV6000C240A4242ND?filename=Schneider+Electric_Altivar-Process-ATV6000_ATV6000C240A4242ND.pdf', 'path_name': 'ba937a9a2e23605e6aa043497ea321b7.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/ba937a9a2e23605e6aa043497ea321b7.pdf', 'status': 1}","sourceUrl":"https://www.se.com/us/en/product/ATV6000C240A4242ND/medium-voltage-variable-speed-drive-atv6000-4-16-kv-2574-hp-ul-certification/"},"ai":{"faq":[{"question":"What is ATV6000C240A4242ND's motor power rating?","answer":"1920 kW normal duty and 1540 kW heavy duty, with line current 333 A normal / 267 A heavy duty."},{"question":"What compliance documentation does Schneider Electric provide for ATV6000C240A4242ND?","answer":"The drive carries cULus, CE, and UKCA markings and complies with IEC 61800-3/-4/-5-1, IEC 60529, IEEE 519:1992, and UL 347A."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV6000C240A4242ND","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV6000C240A4242ND when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}