{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV6000C338A4242NA3","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV6000C338A4242NA3","canonicalUrl":"https://aoctrl.com/schneider/ATV6000C338A4242NA3","factsUrl":"https://aoctrl.com/api/mcp/products/ATV6000C338A4242NA3","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV6000, ATV6000C338A4242NA3, medium-voltage variable speed drive, 2700 kW normal duty / 2360 kW heavy duty, 3380 kVA, 24-pulse diode rectifier, floor-standing enclosure.","salesMarkdown":"The Schneider ATV6000C338A4242NA3 is a medium-voltage variable speed drive from the Altivar Process ATV6000 range, built for large induction, synchronous, and permanent-magnet motors. It delivers 2700 kW in normal duty and 2360 kW in heavy duty, with an apparent power rating of 3380 kVA. The 24-pulse diode rectifier front end keeps input current THDI below 3% per IEEE 519-1992, so it meets utility harmonic limits without external filters in most installations. Line current is 408 A for heavy-duty motor loads and 470 A for normal-duty applications — that is the input draw you need to size the upstream transformer and cabling for. Power losses run 102.6 kW heavy duty and 117.3 kW normal duty, which drives the ventilation requirement for the room or enclosure. The drive itself is floor-standing, 5360 mm wide, 2751 mm high, and 1700 mm deep — plan the footprint and lifting access accordingly. Output voltage is equal to or less than the supply voltage, so the motor sees the same voltage class as the incoming line. The integrated EMC filter meets IEC 61800-3 category C3 on the control side and C4 on the power side, which covers most industrial environments without add-on filtering. This class of drive is specified for large pumps, fans, compressors, conveyors, and mill drives in heavy industries — oil and gas, mining, water/wastewater, cement, and metals. The 24-pulse rectifier and <3% THDI make it a natural fit for sites with sensitive upstream equipment or utility-imposed harmonic limits. The 10-inch LCD touch screen HMI provides local monitoring and parameter access in multiple languages.","metaTitle":"Schneider ATV6000C338A4242NA3 ATV6000 VFD, 2700 kW, 3380 kVA","metaDescription":"Schneider ATV6000C338A4242NA3 medium-voltage VFD, 2700 kW normal duty, 3380 kVA apparent power, 24-pulse rectifier, <3% THDI. Current production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"1700.0 mm","Width":"5360.0 mm","Height":"2751.0 mm","Supply":"Internal supply for digital inputs and PoE 24 V DC 21...27 V, Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, External supply for digital inputs 24 V DC 19...30 V External supply for control circuit 100...240 V AC 47...63 Hz External supply for control circuit 120...370 V DC +/- 10 % 1 kVA Auxiliary power supply 230 V AC +/- 10 % External supply for cooling fan 400 V AC +/- 10 % 17 kVA","Marking":"CE EAC","Isolation":"Electrical between power and control","Standards":"IEC 61800-3 EN/IEC 61800-4 IEC 61800-5-1 IEC 60529 IEEE 519:1992 EN/IEC 60076","EMC filter":"Integrated conforming to IEC 61800-3 category C3 control Integrated conforming to IEC 61800-3 category C4 power","Input type":"24 pulse diode rectifier bridge","Cable Entry":"Bottom","Noise level":"83 dB","Option card":"Slot A: communication module for Profibus DP V1 Slot A: communication module for PROFINET Slot A: communication module for DeviceNet Slot A: communication module for CANopen daisy chain RJ45 Slot A: communication module for CANopen SUB-D 9 Slot A: communication module for CANopen screw terminals Slot A: communication module for EtherCAT Slot B: 5/12 V digital encoder interface module Slot B: analog encoder interface module Slot B: resolver encoder interface module Slot B: HTL encoder interface module Slot A/slot B: digital and analog I/O extension module Slot A/slot B: output relay extension module","Output type":"IGBT inverter cells multilevel PWM","Display type":"10 inch LCD touch screen multi-language","Line current":"408 A heavy duty 470 A normal duty","Maximum THDI":"<3 % conforming to IEEE 519-1992","Power factor":"96","Power losses":"117.3 kW normal duty 102.6 kW heavy duty","Apparent power":"3380 kVA","Assembly style":"In floor-standing enclosure","Connector type":"2 RJ45 (on the control block) for Ethernet IP/Modbus TCP 1 RJ45 (on the control block) for Modbus serial","Motor power kW":"2700 kW for normal duty 2360 kW for heavy duty","Output voltage":"<= power supply voltage","Protection type":"Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overvoltages on the DC bus: drive Thermal overload for transformer: drive Cabinet overheating: drive Overcurrent: drive Overload: drive Short-circuit protection: drive IGBT for each cell: drive Thermal protection: motor Motor phase break: motor Motor earth fault: motor Break on the control circuit: drive Fan monitoring: drive","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to IEC 61800-5-1","Range of product":"Altivar Process ATV6000","Supply frequency":"50 Hz +/- 5 %","Device short name":"ATV6000","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Relay output type":"Configurable relay logic R1: fault relay NO/NC Configurable relay logic R2: sequence relay NO Configurable relay logic R3: sequence relay NO","Operating altitude":"1000...2000 m with derating factor","Provided equipment":"Power cells Phase-shifting transformer Cooling fans Human machine interface Medium voltage arrestors Enclosure Plinth","Analogue input type":"configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution: 12 bits configurable current: 0...20 mA, impedance: 250 Ohm, resolution: 12 bits","Colour of enclosure":"Light grey (RAL 7035)","Discrete input type":"DI1...DI8 programmable, 24 V DC ( DI7, DI8 programmable as pulse input: 0...30 kHz, 24 V DC ( POEA, POEB PWM output enable, 24 V DC (<= 30 V), impedance: > 2.2 kOhm","Product destination":"Permanent magnet motors Synchronous motors Asynchronous motors","Relay output number":"3","Analogue output type":"Configurable voltage: 0...10 V DC impedance 470 Ohm, resolution 10 bits Configurable current: 0...20 mA impedance 500 Ohm, resolution 10 bits","Discrete output type":"Logic output <= 30 V DC 100 mA","Frequency resolution":"0.01 Hz","Overvoltage category":"II conforming to IEC 61800-5-1 motor side III conforming to IEC 61800-5-1 line side III conforming to IEC 61800-5-1 low voltage connections","Prospective line Isc":"31.5 kA for 150 ms","Discrete input number":"10","Volume of cooling air":"22080 m3/h","Analogue output number":"2","Discrete output number":"2","Energy efficiency ratio":"0.985 inverter 0.96 total drive including transformer","IP degree of protection":"IP31 conforming to IEC 60529","Network number of phases":"3 phases","Continuous output current":"392 A heavy duty 448 A normal duty","Maximum transient current":"735 A during 3 s (heavy duty) 672 A during 3 s (normal duty)","Product or component type":"Medium voltage variable speed drive","[Us] rated supply voltage":"4.16 kV +/- 10 %","Communication port protocol":"Ethernet IP/Modbus TCP","Environmental characteristic":"3K3 conforming to IEC 60721-3-3 3B1 conforming to IEC 60721-3-3 3C2 conforming to IEC 60721-3-3 3S1 conforming to IEC 60721-3-3 3M1 conforming to IEC 60721-3-3","Product specific application":"Process and utilities","Speed drive output frequency":"0.1...120 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Synchronous motor control profile":"Permanent magnet control in open loop Permanent magnet control in close loop Line start permanent magnet motor","Asynchronous motor control profile":"Closed loop vector control U/F vector control Energy saving control Vector control with slip compensation in open loop","Ambient air temperature for storage":"0...50 °C","Permissible temporary current boost":"1.2 x In during 60 s (normal duty) 1.5 x In during 3 s (normal duty) 1.5 x In during 60 s (heavy duty) 1.8 x In during 3 s (heavy duty)","Ambient air temperature for operation":"0...40 °C 40...50 °C with derating factor -25...70 °C during transport"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/be/en/product/ATV6000C338A4242NA3/medium-voltage-variable-speed-drive-atv6000-4-16-kv-3380-kva/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ATV6000C338A4242NA3/alternatives.json"},"ai":{"faq":[{"question":"What are the key electrical ratings for this drive?","answer":"It is rated for 2700 kW normal duty / 2360 kW heavy duty motor power, 3380 kVA apparent power, 408 A heavy-duty line current, and 470 A normal-duty line current. Input THDI is below 3% per IEEE 519-1992."},{"question":"What are the physical dimensions of the ATV6000C338A4242NA3?","answer":"The floor-standing enclosure measures 5360 mm wide, 2751 mm high, and 1700 mm deep."},{"question":"What compliance standards does this drive meet?","answer":"It carries CE and EAC marking and complies with IEC 61800-3, IEC 61800-4, IEC 61800-5-1, IEC 60529, IEEE 519:1992, and EN/IEC 60076."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV6000C338A4242NA3","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV6000C338A4242NA3 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}