{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV6000C817A1111NA3","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV6000C817A1111NA3","canonicalUrl":"https://aoctrl.com/schneider/ATV6000C817A1111NA3","factsUrl":"https://aoctrl.com/api/mcp/products/ATV6000C817A1111NA3","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV6000, ATV6000C817A1111NA3, medium-voltage variable speed drive, 8170 kVA, 5220 kW heavy duty / 6530 kW normal duty, 340 A heavy duty / 429 A normal duty line current.","salesMarkdown":"## Medium-voltage drive for large induction and synchronous motors The Schneider Electric ATV6000C817A1111NA3 is a medium-voltage variable speed drive from the Altivar Process ATV6000 series. It is designed to control asynchronous, synchronous, and permanent magnet motors up to 5220 kW in heavy duty or 6530 kW in normal duty, with an apparent power rating of 8170 kVA. The drive is built as a floor-standing enclosure and includes a phase-shifting transformer, medium-voltage arrestors, power cells, cooling fans, and a 10-inch LCD touch screen HMI. ## Duty ratings and input characteristics Line current is rated 340 A for heavy duty and 429 A for normal duty. The 54-pulse diode rectifier bridge keeps total harmonic current distortion (THDi) below 3 %, conforming to IEEE 519-1992. Power factor is 96 %. ## Control supply and I/O The control circuit accepts 100…240 V AC 47…63 Hz or 120…370 V DC. Digital inputs are 24 V DC, with two configurable as pulse inputs up to 30 kHz. Analog inputs are configurable as 0…10 V DC or 0…20 mA, 12-bit resolution. Three configurable relay outputs are provided for fault and sequence signaling. ## Communications and option slots Two RJ45 ports on the control block support Ethernet/IP and Modbus TCP; one RJ45 is dedicated to Modbus serial. Slot A accepts communication modules for Profibus DP V1, PROFINET, DeviceNet, CANopen (RJ45, SUB-D 9, or screw terminals), or EtherCAT. Slot B accepts encoder interface modules (5/12 V digital, analog, resolver, or HTL). Both slots can also house digital/analog I/O extension or output relay extension modules. ## Protection and environmental Protections cover line supply overvoltage, undervoltage, and phase loss; DC bus overvoltage; thermal overload for transformer; cabinet overheating; overcurrent, overload, short-circuit, and IGBT fault per cell; motor thermal protection, phase break, and earth fault. Cooling is forced convection. The enclosure is rated IP for indoor installation, pollution degree 2 per IEC 61800-5-1. Operating altitude is 1000…2000 m with derating. Relative humidity 5…95 % without condensation. Lifecycle stage is current. The ATV6000C817A1111NA3 is an active catalog number.","metaTitle":"Schneider ATV6000C817A1111NA3 MV Drive, 8170 kVA, 5220 kW HD","metaDescription":"Schneider Electric ATV6000C817A1111NA3 medium-voltage variable speed drive. 8170 kVA apparent power, 5220 kW heavy duty / 6530 kW normal duty motor rating. Current lifecycle stage:","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"1800.0 mm","Width":"9470.0 mm","Height":"3151.0 mm","Supply":"Internal supply for digital inputs and PoE 24 V DC 21...27 V, Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, External supply for digital inputs 24 V DC 19...30 V External supply for control circuit 100...240 V AC 47...63 Hz External supply for control circuit 120...370 V DC +/- 10 % 1 kVA Auxiliary power supply 230 V AC +/- 10 % External supply for cooling fan 400 V AC +/- 10 % 26 kVA","Marking":"EAC CE","Isolation":"Electrical between power and control","Standards":"IEC 61800-3 EN/IEC 61800-4 IEC 61800-5-1 IEC 60529 IEEE 519:1992 EN/IEC 60076","EMC filter":"Integrated conforming to IEC 61800-3 category C3 control Integrated conforming to IEC 61800-3 category C4 power","Input type":"54 pulse diode rectifier bridge","Cable Entry":"Bottom","Noise level":"83 dB","Option card":"Slot A: communication module for Profibus DP V1 Slot A: communication module for PROFINET Slot A: communication module for DeviceNet Slot A: communication module for CANopen daisy chain RJ45 Slot A: communication module for CANopen SUB-D 9 Slot A: communication module for CANopen screw terminals Slot A: communication module for EtherCAT Slot B: 5/12 V digital encoder interface module Slot B: analog encoder interface module Slot B: resolver encoder interface module Slot B: HTL encoder interface module Slot A/slot B: digital and analog I/O extension module Slot A/slot B: output relay extension module","Output type":"IGBT inverter cells multilevel PWM","Display type":"10 inch LCD touch screen multi-language","Line current":"340 A heavy duty 429 A normal duty","Maximum THDI":"<3 % conforming to IEEE 519-1992","Power factor":"96","Power losses":"247.2 kW normal duty 197.6 kW heavy duty","Apparent power":"8170 kVA","Assembly style":"In floor-standing enclosure","Connector type":"2 RJ45 (on the control block) for Ethernet IP/Modbus TCP 1 RJ45 (on the control block) for Modbus serial","Motor power kW":"5220 kW for heavy duty 6530 kW for normal duty","Output voltage":"<= power supply voltage","Protection type":"Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overvoltages on the DC bus: drive Thermal overload for transformer: drive Cabinet overheating: drive Overcurrent: drive Overload: drive Short-circuit protection: drive IGBT for each cell: drive Thermal protection: motor Motor phase break: motor Motor earth fault: motor Break on the control circuit: drive Fan monitoring: drive","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to IEC 61800-5-1","Range of product":"Altivar Process ATV6000","Supply frequency":"50 Hz +/- 5 %","Device short name":"ATV6000","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Relay output type":"Configurable relay logic R1: fault relay NO/NC Configurable relay logic R2: sequence relay NO Configurable relay logic R3: sequence relay NO","Operating altitude":"1000...2000 m with derating factor","Provided equipment":"Medium voltage arrestors Power cells Plinth Cooling fans Human machine interface Enclosure Phase-shifting transformer","Analogue input type":"configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution: 12 bits configurable current: 0...20 mA, impedance: 250 Ohm, resolution: 12 bits","Colour of enclosure":"Light grey (RAL 7035)","Discrete input type":"DI1...DI8 programmable, 24 V DC ( DI7, DI8 programmable as pulse input: 0...30 kHz, 24 V DC ( POEA, POEB PWM output enable, 24 V DC (<= 30 V), impedance: > 2.2 kOhm","Product destination":"Synchronous motors Asynchronous motors Permanent magnet motors","Relay output number":"3","Analogue output type":"Configurable voltage: 0...10 V DC impedance 470 Ohm, resolution 10 bits Configurable current: 0...20 mA impedance 500 Ohm, resolution 10 bits","Discrete output type":"Logic output <= 30 V DC 100 mA","Frequency resolution":"0.01 Hz","Overvoltage category":"II conforming to IEC 61800-5-1 motor side III conforming to IEC 61800-5-1 line side III conforming to IEC 61800-5-1 low voltage connections","Prospective line Isc":"31.5 kA for 150 ms","Discrete input number":"10","Volume of cooling air":"54299 m3/h","Analogue output number":"2","Discrete output number":"2","Energy efficiency ratio":"0.985 inverter 0.96 total drive including transformer","IP degree of protection":"IP31 conforming to IEC 60529","Network number of phases":"3 phases","Continuous output current":"328 A heavy duty 410 A normal duty","Maximum transient current":"615 A during 3 s (heavy duty) 615 A during 3 s (normal duty)","Product or component type":"Medium voltage variable speed drive","[Us] rated supply voltage":"11 kV +/- 10 %","Communication port protocol":"Ethernet IP/Modbus TCP","Environmental characteristic":"3K3 conforming to IEC 60721-3-3 3B1 conforming to IEC 60721-3-3 3C2 conforming to IEC 60721-3-3 3S1 conforming to IEC 60721-3-3 3M1 conforming to IEC 60721-3-3","Product specific application":"Process and utilities","Speed drive output frequency":"0.1...120 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Synchronous motor control profile":"Permanent magnet control in open loop Permanent magnet control in close loop Line start permanent magnet motor","Asynchronous motor control profile":"Closed loop vector control U/F vector control Energy saving control Vector control with slip compensation in open loop","Ambient air temperature for storage":"0...50 °C","Permissible temporary current boost":"1.2 x In during 60 s (normal duty) 1.5 x In during 3 s (normal duty) 1.5 x In during 60 s (heavy duty) 1.8 x In during 3 s (heavy duty)","Ambient air temperature for operation":"0...40 °C 40...50 °C with derating factor -25...70 °C during transport"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/be/en/product/ATV6000C817A1111NA3/medium-voltage-variable-speed-drive-atv6000-11-kv-8170-kva/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ATV6000C817A1111NA3/alternatives.json"},"ai":{"faq":[{"question":"What is the motor power rating for this drive?","answer":"5220 kW for heavy duty and 6530 kW for normal duty."},{"question":"What are the key input current ratings?","answer":"340 A for heavy duty and 429 A for normal duty."},{"question":"What communications protocols are supported?","answer":"Ethernet/IP, Modbus TCP, Modbus serial, plus option modules for Profibus DP V1, PROFINET, DeviceNet, CANopen, and EtherCAT."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV6000C817A1111NA3","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV6000C817A1111NA3 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}