{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV6000D500A1111NA3","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV6000D500A1111NA3","canonicalUrl":"https://aoctrl.com/schneider/ATV6000D500A1111NA3","factsUrl":"https://aoctrl.com/api/mcp/products/ATV6000D500A1111NA3","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV6000, ATV6000D500A1111NA3, AC Drive (VFD) 480V, 400 kW normal duty / 380 kW heavy duty, 500 kVA apparent power, floor-standing enclosure, 54-pulse diode rectifier.","salesMarkdown":"## 400 kW drive in a floor-standing enclosure The ATV6000D500A1111NA3 is a Schneider Electric Altivar Process ATV6000 AC drive rated for 400 kW normal duty and 380 kW heavy duty motor power, with an apparent power rating of 500 kVA. It ships as a complete floor-standing enclosure assembly — 2751 mm high, 3860 mm wide, 1600 mm deep — integrating the phase-shifting transformer, power cells, cooling fans, and HMI. ## Line-side harmonics and input topology A 54-pulse diode rectifier bridge feeds the DC bus, keeping total harmonic current distortion below 3 % per IEEE 519:1992 without an external filter. The power factor sits at 0.96, and the integrated EMC filter meets IEC 61800-3 category C3 on the control side and C4 on the power side. ## Motor types and output stage The output uses IGBT inverter cells in a multilevel PWM topology, suitable for asynchronous, synchronous, and permanent magnet motors. Output voltage matches the supply voltage; the drive includes motor thermal protection, phase-loss detection, and earth-fault monitoring. ## Control interfaces and expandability The control block carries two RJ45 ports for Ethernet IP / Modbus TCP and one RJ45 for Modbus serial. Slot A accepts fieldbus option cards for Profibus DP V1, PROFINET, DeviceNet, CANopen, or EtherCAT. Slot B supports encoder feedback modules (digital 5/12 V, analog, resolver, or HTL). Digital and analog I/O or relay extension modules fit either slot. The 10-inch LCD touch screen provides multi-language local control and monitoring. ## Regulatory compliance and lifecycle Marked EAC and CE, designed to IEC 61800-3, IEC 61800-4, IEC 61800-5-1, and IEC 60529. Pollution degree 2 per IEC 61800-5-1.","metaTitle":"Schneider ATV6000D500A1111NA3 AC Drive, 400 kW, 500 kVA","metaDescription":"Schneider Electric ATV6000D500A1111NA3 Altivar Process ATV6000 AC drive, 400 kW normal duty, 500 kVA apparent power, 54-pulse input, floor-standing enclosure.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"1600.0 mm","Width":"3860.0 mm","title":"ATV6000D500A1111NA3","Height":"2751.0 mm","Supply":"Internal supply for digital inputs and PoE 24 V DC 21...27 V, Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, External supply for digital inputs 24 V DC 19...30 V External supply for control circuit 100...240 V AC 47...63 Hz External supply for control circuit 120...370 V DC +/- 10 % 1 kVA Auxiliary power supply 230 V AC +/- 10 % External supply for cooling fan 400 V AC +/- 10 % 6 kVA","Marking":"EAC CE","Isolation":"Electrical between power and control","Standards":"IEC 61800-3 EN/IEC 61800-4 IEC 61800-5-1 IEC 60529 IEEE 519:1992 EN/IEC 60076","EMC filter":"Integrated conforming to IEC 61800-3 category C3 control Integrated conforming to IEC 61800-3 category C4 power","Input type":"54 pulse diode rectifier bridge","Cable Entry":"Bottom","Noise level":"80 dB","Option card":"Slot A: communication module for Profibus DP V1 Slot A: communication module for PROFINET Slot A: communication module for DeviceNet Slot A: communication module for CANopen daisy chain RJ45 Slot A: communication module for CANopen SUB-D 9 Slot A: communication module for CANopen screw terminals Slot A: communication module for EtherCAT Slot B: 5/12 V digital encoder interface module Slot B: analog encoder interface module Slot B: resolver encoder interface module Slot B: HTL encoder interface module Slot A/slot B: digital and analog I/O extension module Slot A/slot B: output relay extension module","Output type":"IGBT inverter cells multilevel PWM","description":"Medium Voltage Variable Speed Drive ATV6000 - 11 kV - 500 kVA","Display type":"10 inch LCD touch screen multi-language","Line current":"26.3 A normal duty 25 A heavy duty","Maximum THDI":"<3 % conforming to IEEE 519-1992","Power factor":"96","Power losses":"17.5 kW normal duty 16.6 kW heavy duty","Apparent power":"500 kVA","Assembly style":"In floor-standing enclosure","Connector type":"2 RJ45 (on the control block) for Ethernet IP/Modbus TCP 1 RJ45 (on the control block) for Modbus serial","Motor power kW":"400 kW for normal duty 380 kW for heavy duty","Output voltage":"<= power supply voltage","Protection type":"Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overvoltages on the DC bus: drive Thermal overload for transformer: drive Cabinet overheating: drive Overcurrent: drive Overload: drive Short-circuit protection: drive IGBT for each cell: drive Thermal protection: motor Motor phase break: motor Motor earth fault: motor Break on the control circuit: drive Fan monitoring: drive","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to IEC 61800-5-1","Range of product":"Altivar Process ATV6000","Supply frequency":"50 Hz +/- 5 %","Device short name":"ATV6000","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Relay output type":"Configurable relay logic R1: fault relay NO/NC Configurable relay logic R2: sequence relay NO Configurable relay logic R3: sequence relay NO","Operating altitude":"1000...2000 m with derating factor","Provided equipment":"Human machine interface Power cells Plinth Cooling fans Enclosure Phase-shifting transformer Medium voltage arrestors","Analogue input type":"configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution: 12 bits configurable current: 0...20 mA, impedance: 250 Ohm, resolution: 12 bits","Colour of enclosure":"Light grey (RAL 7035)","Discrete input type":"DI1...DI8 programmable, 24 V DC ( DI7, DI8 programmable as pulse input: 0...30 kHz, 24 V DC ( POEA, POEB PWM output enable, 24 V DC (<= 30 V), impedance: > 2.2 kOhm","Product destination":"Synchronous motors Asynchronous motors Permanent magnet motors","Relay output number":"3","Analogue output type":"Configurable voltage: 0...10 V DC impedance 470 Ohm, resolution 10 bits Configurable current: 0...20 mA impedance 500 Ohm, resolution 10 bits","Discrete output type":"Logic output <= 30 V DC 100 mA","Frequency resolution":"0.01 Hz","Overvoltage category":"II conforming to IEC 61800-5-1 motor side III conforming to IEC 61800-5-1 line side III conforming to IEC 61800-5-1 low voltage connections","Prospective line Isc":"31.5 kA for 150 ms","Discrete input number":"10","Volume of cooling air":"14580 m3/h","Analogue output number":"2","Discrete output number":"2","Energy efficiency ratio":"0.985 inverter 0.96 total drive including transformer","IP degree of protection":"IP31 conforming to IEC 60529","Network number of phases":"3 phases","Continuous output current":"25.1 A normal duty 24 A heavy duty","Maximum transient current":"37.6 A during 3 s (normal duty) 45 A during 3 s (heavy duty)","Product or component type":"Medium voltage variable speed drive","[Us] rated supply voltage":"11 kV +/- 10 %","Communication port protocol":"Ethernet IP/Modbus TCP","Environmental characteristic":"3K3 conforming to IEC 60721-3-3 3B1 conforming to IEC 60721-3-3 3C2 conforming to IEC 60721-3-3 3S1 conforming to IEC 60721-3-3 3M1 conforming to IEC 60721-3-3","Product specific application":"Process and utilities","Speed drive output frequency":"0.1...120 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Synchronous motor control profile":"Permanent magnet control in open loop Permanent magnet control in close loop Line start permanent magnet motor","Asynchronous motor control profile":"Closed loop vector control U/F vector control Energy saving control Vector control with slip compensation in open loop","Ambient air temperature for storage":"0...50 °C","Permissible temporary current boost":"1.2 x In during 60 s (normal duty) 1.5 x In during 3 s (normal duty) 1.5 x In during 60 s (heavy duty) 1.8 x In during 3 s (heavy duty)","Ambient air temperature for operation":"0...40 °C 40...50 °C with derating factor -25...70 °C during transport"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/be/en/product/ATV6000D500A1111NA3/medium-voltage-variable-speed-drive-atv6000-11-kv-500-kva/"},"ai":{"faq":[{"question":"What compliance documentation does Schneider Electric provide for ATV6000D500A1111NA3?","answer":"The drive carries EAC and CE markings and is designed to IEC 61800-3, IEC 61800-4, IEC 61800-5-1, and IEC 60529. The declaration of conformity covers the full assembly."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV6000D500A1111NA3","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV6000D500A1111NA3 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}