{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV6000D780A6666ND","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV6000D780A6666ND","canonicalUrl":"https://aoctrl.com/schneider/ATV6000D780A6666ND","factsUrl":"https://aoctrl.com/api/mcp/products/ATV6000D780A6666ND","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV6000, ATV6000D780A6666ND, medium-voltage drive, 3-phase, 780 kVA apparent power, 590 kW heavy duty / 620 kW normal duty motor power, floor-standing enclosure.","salesMarkdown":"The Schneider Electric ATV6000D780A6666ND is an Altivar Process ATV6000 medium-voltage drive in a floor-standing enclosure, rated for 3-phase supply with a 30-pulse diode rectifier bridge input and IGBT multilevel PWM output. It delivers 780 kVA apparent power and handles motor loads up to 620 kW normal duty or 590 kW heavy duty. Line current is 68.3 A normal duty, 65 A heavy duty, with total harmonic current distortion below 3% per IEEE 519-1992. Power factor sits at 96%. The 30-pulse input topology keeps input harmonics low enough to meet IEEE 519 without external filters in most installations — the <3% THDI figure is the headline. The integrated EMC filter covers IEC 61800-3 category C3 on the control side and C4 on the power side, which means the drive is intended for industrial environments with a separate transformer or dedicated supply. The 10-inch LCD touchscreen HMI is multi-language and supports local commissioning and fault diagnostics. Three configurable relay outputs (R1 fault, R2 and R3 sequence) and eight programmable digital inputs are on the control block, plus two RJ45 ports for Ethernet IP/Modbus TCP and one for Modbus serial. Option card slots A and B accept a range of fieldbus modules (Profibus DP V1, PROFINET, DeviceNet, CANopen, EtherCAT) and encoder interfaces (digital, analog, resolver, HTL), plus digital/analog I/O and relay extension modules. Slot selection determines network integration — plan the communication protocol before ordering. ## Compliance & environment Marked CULus, CE, UKCA. Designed to IEC 61800-3, IEC 61800-4, IEC 61800-5-1, IEC 60529, IEEE 519:1992, EN/IEC 60076, and UL 347A. Pollution degree 2 per IEC 61800-5-1. Ambient relative humidity 5–95% non-condensing. Noise level is 80 dB — this is a forced-convection-cooled drive in a floor-standing cabinet; plan for acoustic enclosure or hearing protection if the drive is in a manned area. Power losses are 27 kW normal duty, 25.7 kW heavy duty, so ventilation or air conditioning in the room must handle that heat load.","metaTitle":"Schneider ATV6000D780A6666ND Altivar Process Drive, 780 kVA,","metaDescription":"Schneider ATV6000D780A6666ND Altivar Process ATV6000 medium-voltage drive, 780 kVA apparent power, 3-phase, 30-pulse input, active production. Sourced to order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"55.1 in (1400.0 mm)","Phase":"3 phase","Width":"108.7 in (2760.0 mm)","title":"ATV6000D780A6666ND","Height":"103.03 in (2617.0 mm)","Supply":"Internal supply for digital inputs and PoE 24 V DC 21...27 V, Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, External supply for digital inputs 24 V DC 19...30 V External supply for control circuit 100...240 V AC 47...63 Hz External supply for control circuit 120...370 V DC +/- 10 % 1 kVA Auxiliary power supply 230 V AC +/- 10 % External supply for cooling fan 400 V AC +/- 10 % 7 kVA","Marking":"CULus CE UKCA","Isolation":"Electrical between power and control","Standards":"IEC 61800-3 EN/IEC 61800-4 IEC 61800-5-1 IEC 60529 IEEE 519:1992 EN/IEC 60076 UL 347A","EMC filter":"Integrated IEC 61800-3 category C3 control Integrated IEC 61800-3 category C4 Power","Input type":"30 pulse diode rectifier bridge","Cable Entry":"Bottom","Noise level":"80 dB","Option card":"Slot A communication module Profibus DP V1 Slot A communication module PROFINET Slot A communication module DeviceNet Slot A communication module CANopen daisy chain RJ45 Slot A communication module CANopen SUB-D 9 Slot A communication module CANopen screw terminals Slot A communication module EtherCAT Slot B 5/12 V digital encoder interface module Slot B analog encoder interface module Slot B resolver encoder interface module Slot B HTL encoder interface module Slot A/slot B digital and analog I/O extension module Slot A/slot B output relay extension module","Output type":"IGBT inverter cells multilevel PWM","description":"Medium Voltage Variable Speed Drive ATV6000, 6.6 kV, 831 hp, UL certification","Display type":"10 inch LCD touch screen multi-language","Line current":"68.3 A normal duty 65 A heavy duty","Maximum THDI":"<3 % IEEE 519-1992","Power factor":"96","Power losses":"27 kW normal duty 25.7 kW heavy duty","Apparent power":"780 kVA","Assembly style":"In floor-standing enclosure","Connector type":"2 RJ45 on the control block)Ethernet IP/Modbus TCP 1 RJ45 on the control block)Modbus serial","Motor power kW":"590 kW heavy duty 620 kW normal duty","Output voltage":"<= power supply voltage","Protection type":"Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overvoltages on the DC bus drive Thermal overload for transformer drive Cabinet overheating drive Overcurrent drive Overload drive Short-circuit protection drive IGBT for each cell drive Thermal protection motor Motor phase break motor Motor earth fault motor Break on the control circuit drive Fan monitoring drive","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 IEC 61800-5-1","Range of Product":"Altivar Process ATV6000","Supply frequency":"50 Hz +/- 5 %","Device short name":"ATV6000","Relative humidity":"5...95 % without condensation IEC 60068-2-3","Relay output type":"Configurable relay logic R1 fault relay NO/NC Configurable relay logic R2 sequence relay NO Configurable relay logic R3 sequence relay NO","Operating altitude":"3280.84...6561.68 ft (1000...2000 m) with derating factor","Provided Equipment":"Plinth Cooling fans Power cells Medium voltage arrestors Phase-shifting transformer Human machine interface Enclosure","Analogue input type":"configurable voltage 0...10 V DC 30 kOhm 12 bits configurable current 0...20 mA 250 Ohm 12 bits","Colour of enclosure":"Light grey RAL 7035)","Discrete input type":"DI1...DI8 programmable, 24 V DC DI7, DI8 programmable as pulse input 0...30 kHz, 24 V DC POEA, POEB PWM output enable, 24 V DC 2.2 kOhm","Product destination":"Asynchronous motors Permanent magnet motors Synchronous motors","Relay output number":"3","Analogue output type":"Configurable voltage 0...10 V DC 470 Ohm 10 bits Configurable current 0...20 mA 500 Ohm 10 bits","Discrete output type":"Logic output <= 30 V DC 100 mA","Frequency resolution":"0.01 Hz","Overvoltage category":"II IEC 61800-5-1 motor side III IEC 61800-5-1 line side III IEC 61800-5-1 low voltage connections","Prospective line Isc":"31.5 kA 150 ms","Discrete input number":"10","Volume of cooling air":"2705064.6 Gal/hr(US) (10239.6 m3/h)","Analogue output number":"2","Discrete output number":"2","Energy efficiency ratio":"0.985 inverter 0.96 total drive including transformer","IP degree of protection":"IP31 conforming to IEC 60529","Continuous output current":"65 A normal duty 62 A heavy duty","Maximum transient current":"97.5 A 3 s normal duty) 116 A 3 s heavy duty)","Product or Component Type":"Medium voltage variable speed drive","[Us] rated supply voltage":"6.6 kV +/- 10 %","Maximum Horse Power Rating":"791.0 hp heavy duty 831.0 hp normal duty","Communication Port Protocol":"Ethernet IP/Modbus TCP","Environmental characteristic":"3K3 conforming to IEC 60721-3-3 3B1 conforming to IEC 60721-3-3 3C2 conforming to IEC 60721-3-3 3S1 conforming to IEC 60721-3-3 3M1 conforming to IEC 60721-3-3","Product Specific Application":"Process and utilities","Speed drive output frequency":"0.1...120 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Synchronous motor control profile":"Permanent magnet control in open loop Permanent magnet control in close loop Line start permanent magnet motor","Asynchronous motor control profile":"Closed loop vector control U/F vector control Energy saving control Vector control with slip compensation in open loop","Ambient Air Temperature for Storage":"32...122 °F (0...50 °C)","Permissible temporary current boost":"1.2 x In 60 s normal duty) 1.5 x In 3 s normal duty) 1.5 x In 60 s heavy duty) 1.8 x In 3 s heavy duty)","Ambient air temperature for operation":"32...104 °F (0...40 °C) 104...122 °F (40...50 °C) with derating factor -13...158 °F (-25...70 °C) during transport"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/us/en/product/download-pdf/ATV6000D780A6666ND?filename=Schneider+Electric_Altivar-Process-ATV6000_ATV6000D780A6666ND.pdf', 'path_name': 'eeb85b7eb22cbd147e094158d9e58300.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/eeb85b7eb22cbd147e094158d9e58300.pdf', 'status': 1}","sourceUrl":"https://www.se.com/us/en/product/ATV6000D780A6666ND/medium-voltage-variable-speed-drive-atv6000-6-6-kv-831-hp-ul-certification/"},"ai":{"faq":[{"question":"What are the key motor power ratings for this drive?","answer":"It handles 620 kW normal duty and 590 kW heavy duty, with an apparent power rating of 780 kVA."},{"question":"What fieldbus options are available for this drive?","answer":"Slot A accepts Profibus DP V1, PROFINET, DeviceNet, CANopen (daisy chain RJ45, SUB-D 9, or screw terminals), and EtherCAT modules. Slot B accepts encoder interface modules (digital, analog, resolver, HTL) and I/O or relay extension modules."},{"question":"What compliance standards does the ATV6000D780A6666ND meet?","answer":"It carries CULus, CE, and UKCA markings, and complies with IEC 61800-3, IEC 61800-4, IEC 61800-5-1, IEC 60529, IEEE 519:1992, EN/IEC 60076, and UL 347A."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV6000D780A6666ND","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV6000D780A6666ND when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}