{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV6000D950A2424ND","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV6000D950A2424ND","canonicalUrl":"https://aoctrl.com/schneider/ATV6000D950A2424ND","factsUrl":"https://aoctrl.com/api/mcp/products/ATV6000D950A2424ND","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV6000, ATV6000D950A2424ND, 3-phase, 950 kVA, 610 kW heavy duty / 760 kW normal duty motor power.","salesMarkdown":"The Schneider Electric ATV6000D950A2424ND is an Altivar Process ATV6000 medium-voltage drive in a floor-standing enclosure, rated for 3-phase input and output. It delivers 950 kVA apparent power and handles 610 kW heavy-duty or 760 kW normal-duty motor loads, covering synchronous, asynchronous, and permanent magnet motors. Input harmonics stay under 3 % THDI per IEEE 519-1992 thanks to the 54-pulse diode rectifier bridge, so you can skip external line reactors on most utility feeds. The integrated EMC filter covers both C3 (control) and C4 (power) categories — no add-on filter box needed for most industrial environments. Protection covers the full chain: line over/undervoltage, phase loss, DC bus overvoltage, cabinet overtemperature, IGBT short-circuit per cell, motor thermal and earth fault. That means the drive handles fault isolation itself — no separate motor protection relay required for basic coverage. ## Installation notes Bottom cable entry, forced convection cooling, and a 90.3 dB noise level — plan for ear protection nearby and clearance for airflow under the cabinet. The control supply accepts 100-240 V AC or 120-370 V DC; the cooling fan runs on 400 V AC. Digital inputs are 24 V DC, configurable up to 30 kHz on two inputs for pulse inputs.","metaTitle":"Schneider ATV6000D950A2424ND Altivar Process Drive, 950 kVA","metaDescription":"Schneider Electric ATV6000D950A2424ND Altivar Process ATV6000 drive, 3-phase, 950 kVA, 610/760 kW motor power. Current production. Sourced to order. cULus, CE, UKCA.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Phase":"3 phase","title":"ATV6000D950A2424ND","Supply":"Internal supply for digital inputs and PoE 24 V DC 21...27 V, Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, External supply for digital inputs 24 V DC 19...30 V External supply for control circuit 100...240 V AC 47...63 Hz External supply for control circuit 120...370 V DC +/- 10 % 1 kVA Auxiliary power supply 230 V AC +/- 10 % External supply for cooling fan 400 V AC +/- 10 %","Marking":"CULus CE UKCA","Isolation":"Electrical between power and control","Standards":"IEC 61800-3 EN/IEC 61800-4 IEC 61800-5-1 IEC 60529 IEEE 519:1992 EN/IEC 60076 UL 347A","EMC filter":"Integrated IEC 61800-3 category C3 control Integrated IEC 61800-3 category C4 Power","Input type":"54 pulse diode rectifier bridge","Cable Entry":"Bottom","Noise level":"90.3 dB","Option card":"Slot A communication module Profibus DP V1 Slot A communication module PROFINET Slot A communication module DeviceNet Slot A communication module CANopen daisy chain RJ45 Slot A communication module CANopen SUB-D 9 Slot A communication module CANopen screw terminals Slot A communication module EtherCAT Slot B 5/12 V digital encoder interface module Slot B analog encoder interface module Slot B resolver encoder interface module Slot B HTL encoder interface module Slot A/slot B digital and analog I/O extension module Slot A/slot B output relay extension module","Output type":"IGBT inverter cells multilevel PWM","description":"Medium Voltage Variable Speed Drive ATV6000, 2.4 kV, 1019 hp, UL certification","Display type":"10 inch LCD touch screen multi-language","Line current":"183.0 A heavy duty 264.0 A normal duty","Maximum THDI":"<3 % IEEE 519-1992","Power factor":"96","Apparent power":"950 kVA","Assembly style":"In floor-standing enclosure","Connector type":"2 RJ45 on the control block)Ethernet IP/Modbus TCP 1 RJ45 on the control block)Modbus serial","Motor power kW":"610.0 kW heavy duty 760.0 kW normal duty","Output voltage":"<= power supply voltage","Protection type":"Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overvoltages on the DC bus drive Thermal overload for transformer drive Cabinet overheating drive Overcurrent drive Overload drive Short-circuit protection drive IGBT for each cell drive Thermal protection motor Motor phase break motor Motor earth fault motor Break on the control circuit drive Fan monitoring drive","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 IEC 61800-5-1","Range of Product":"Altivar Process ATV6000","Supply frequency":"50 Hz +/- 5 %","Device short name":"ATV6000","Relative humidity":"5...95 % without condensation IEC 60068-2-3","Relay output type":"Configurable relay logic R1 fault relay NO/NC Configurable relay logic R2 sequence relay NO Configurable relay logic R3 sequence relay NO","Operating altitude":"3280.84...6561.68 ft (1000...2000 m) with derating factor","Provided Equipment":"Cooling fans Human machine interface Plinth Medium voltage arrestors Power cells Enclosure Phase-shifting transformer","Analogue input type":"configurable voltage 0...10 V DC 30 kOhm 12 bits configurable current 0...20 mA 250 Ohm 12 bits","Colour of enclosure":"Light grey RAL 7035)","Discrete input type":"DI1...DI8 programmable, 24 V DC DI7, DI8 programmable as pulse input 0...30 kHz, 24 V DC POEA, POEB PWM output enable, 24 V DC 2.2 kOhm","Product destination":"Synchronous motors Asynchronous motors Permanent magnet motors","Relay output number":"3","Analogue output type":"Configurable voltage 0...10 V DC 470 Ohm 10 bits Configurable current 0...20 mA 500 Ohm 10 bits","Discrete output type":"Logic output <= 30 V DC 100 mA","Frequency resolution":"0.01 Hz","Overvoltage category":"II IEC 61800-5-1 motor side III IEC 61800-5-1 line side III IEC 61800-5-1 low voltage connections","Discrete input number":"10","Analogue output number":"2","Discrete output number":"2","Energy efficiency ratio":"0.985 inverter 0.965 total drive including transformer","IP degree of protection":"IP31 conforming to IEC 60529","Continuous output current":"176.0 A heavy duty 220.0 A normal duty","Maximum transient current":"264.0 A 3 s heavy duty) 264.0 A 3 s normal duty)","Product or Component Type":"Medium voltage variable speed drive","[Us] rated supply voltage":"2.4 kV +/- 10 %","Maximum Horse Power Rating":"818.0 hp heavy duty 1019.0 hp normal duty","Communication Port Protocol":"Ethernet IP/Modbus TCP","Environmental characteristic":"3K3 conforming to IEC 60721-3-3 3B1 conforming to IEC 60721-3-3 3C2 conforming to IEC 60721-3-3 3S1 conforming to IEC 60721-3-3 3M1 conforming to IEC 60721-3-3","Product Specific Application":"Process and utilities","Speed drive output frequency":"0.1...120 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Synchronous motor control profile":"Permanent magnet control in open loop Permanent magnet control in close loop Line start permanent magnet motor","Asynchronous motor control profile":"Closed loop vector control U/F vector control Energy saving control Vector control with slip compensation in open loop","Ambient Air Temperature for Storage":"32...122 °F (0...50 °C)","Permissible temporary current boost":"1.2 x In 60 s normal duty) 1.5 x In 3 s normal duty) 1.5 x In 60 s heavy duty) 1.8 x In 3 s heavy duty)","Ambient air temperature for operation":"32...104 °F (0...40 °C) 104...122 °F (40...50 °C) with derating factor -13...158 °F (-25...70 °C) during transport"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/ca/en/product/download-pdf/ATV6000D950A2424ND?filename=Schneider+Electric_Altivar-Process-ATV6000_ATV6000D950A2424ND.pdf', 'path_name': '1d67efe64bb2dbde0fd8cfc13196ee73.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/1d67efe64bb2dbde0fd8cfc13196ee73.pdf', 'status': 1}","sourceUrl":"https://www.se.com/ca/en/product/ATV6000D950A2424ND/medium-voltage-variable-speed-drive-atv6000-2-4-kv-1019-hp-ul-certification/"},"ai":{"faq":[{"question":"What is the motor power rating for this drive?","answer":"610 kW heavy duty and 760 kW normal duty, covering synchronous, asynchronous, and permanent magnet motors."},{"question":"What compliance markings does it carry?","answer":"cULus, CE, and UKCA, with standards including IEC 61800-3, EN/IEC 61800-4, IEC 61800-5-1, IEEE 519:1992, and UL 347A."},{"question":"What communication options are available?","answer":"Slot A supports Profibus DP V1, PROFINET, DeviceNet, CANopen (RJ45, SUB-D 9, or screw terminals), and EtherCAT. Slot B handles encoder interfaces (digital 5/12 V, analog, resolver, HTL) plus digital/analog I/O and relay extension modules."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV6000D950A2424ND","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV6000D950A2424ND when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}