{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV600SYSTEM","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV600SYSTEM","canonicalUrl":"https://aoctrl.com/schneider/ATV600SYSTEM","factsUrl":"https://aoctrl.com/api/mcp/products/ATV600SYSTEM","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV600, variable speed drive, enclosure full ETO, 380...690 V supply, IP23/IP54, forced convection cooling.","salesMarkdown":"The ATV600SYSTEM is a Schneider Electric Altivar Process ATV600 variable speed drive supplied as a complete floor-standing enclosure — the 'full ETO' variant means it ships with the enclosure, main switch, line choke, dv/dt filter choke, terminal blocks for main supply and motor, and the graphical operating panel already wired in. It is designed for industrial applications requiring a packaged drive solution that arrives ready for power and motor connections, not a component you build into a panel. Supply voltage covers 380...415 V through 690 V (all with -10...6 % tolerance), three-phase, 50/60 Hz ±5 %. Protection is IP23 as standard (conforming to IEC 61800-5-1) and IP54 where the enclosure seal is upgraded — the listing carries both, so verify which your site requires. Forced convection cooling keeps the drive within its -10...50 °C operating band (derated above 40 °C, and requiring enclosure heating below 0 °C). The wide voltage range is the headline: 380 V to 690 V on one SKU simplifies spares stocking for a site with mixed supply voltages. But the altitude derating matters if your installation is above 1000 m — 1 % current derating per 100 m up to 2000 m, and further derating above that for TT/TN/IT earthing systems. The EMC immunity test levels (level 3 for electrostatic discharge and radiated RF, level 4 for fast transients and surges) place it in a heavy industrial environment without external filtering for most cases. Motor control profiles include constant torque, variable torque, optimized torque mode for asynchronous motors, and permanent magnet synchronous motor control. That covers pumps, fans, conveyors, and increasingly common PM motor retrofits on one drive platform. Floor-standing enclosure, compact version, with top and bottom cable entry. Operating position is vertical ±10°. The enclosure colour is light grey (RAL 7035), and the assembly is designed for industrial floor mounting — not wall-mount. Provided equipment includes the dv/dt filter choke, which protects motor insulation on longer cable runs, and the line choke for harmonic mitigation. Vibration resistance meets 3M3 per IEC 60721-3-3 (0.6 gn at 10-200 Hz, 1.5 mm peak-to-peak at 3-10 Hz). Shock resistance is 4 gn for 11 ms, 3M2. That is sufficient for general industrial floor vibration but not for direct mounting on a reciprocating compressor skid without isolation mounts. Environmental classification includes chemical pollution resistance class 3C3, dust pollution resistance 3S3, and humidity resistance 3K3 (5...95 % RH without condensation). Storage temperature is -25...70 °C.","metaTitle":"Schneider Electric ATV600SYSTEM Altivar Process Drive, 380-6","metaDescription":"Active ATV600SYSTEM variable speed drive in floor-standing enclosure, 380-690 V supply, IP23/IP54, forced convection cooling. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 600V"],"specifications":{"title":"ATV600SYSTEM","Marking":"CE","Standards":"IEC 61800-5-1 IEC 61800-3 IEC 60204-1 IEC 61800-2","Cable Entry":"Top Bottom","description":"Variable speed drive, Altivar Process ATV600, Enclosure full ETO","Assembly style":"In floor-standing enclosure compact version","Output voltage":"1 MOhm 500 V DC for 1 minute to earth","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2 conforming to IEC 61800-5-1","Range of product":"Altivar Process ATV600","Shock resistance":"4 gn for 11 ms conforming to IEC 60068-2-27 3M2 conforming to IEC 60721-3-3","Supply frequency":"50/60 Hz +/-5 %","Device short name":"ATV600","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Device application":"Industrial application","Function available":"Customised enclosure colour Customised option card Customised cable entry Customised provided equipment","Operating altitude":"1000...2000 m with current derating 1 % per 100 m 2000...3800 m with current derating 1 % per 100 m for TT earthing system 2000...3800 m with current derating 1 % per 100 m for TN earthing system 2000...3800 m with current derating 1 % per 100 m for IT earthing system 3800...4800 m with current derating 1 % per 100 m for TT earthing system 3800...4800 m with current derating 1 % per 100 m for TN earthing system","Operating position":"Vertical +/- 10 degree","Provided equipment":"Enclosure Spacial SF Graphical operating panel in the enclosure door Frequency inverter Main switch Line choke Terminal block main supply Terminal block motor Dv/dt filter choke","Colour of enclosure":"Light grey (RAL 7035)","Overvoltage category":"III","Vibration resistance":"1.5 mm peak to peak (f= 3...10 Hz) conforming to IEC 60068-2-6 0.6 gn (f= 10...200 Hz) conforming to IEC 60068-2-6 3M3 conforming to IEC 60721-3-3","IP degree of protection":"IP23 conforming to IEC 61800-5-1 IP54","Network number of phases":"3 phases","Product or component type":"Variable speed drive","[Us] rated supply voltage":"380...415 V - 10...6 % 440 V - 10...6 % 480 V - 10...6 % 500 V - 10...6 % 600 V - 10...6 % 690 V - 10...6 %","Environmental characteristic":"Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to IEC 60721-3-3 Humidity resistant class 3K3 conforming to IEC 60721-3-3","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Synchronous motor control profile":"Permanent magnet motor","Asynchronous motor control profile":"Optimized torque mode Variable torque standard Constant torque standard","Ambient air temperature for storage":"-25...70 °C","Ambient air temperature for operation":"-10...0 °C without derating (with option enclosure heating) 0...40 °C without derating 40...50 °C with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e3f4abc9e6c3955f624525ce00a7d699.pdf","sourceUrl":"https://www.se.com/uk/en/product/ATV600SYSTEM/variable-speed-drive-altivar-process-atv600-enclosure-full-eto/"},"ai":{"faq":[{"question":"What enclosure protection does the ATV600SYSTEM offer?","answer":"The standard protection is IP23 per IEC 61800-5-1, with IP54 also listed — verify which variant your site requires. The enclosure is a floor-standing compact version with top and bottom cable entry."},{"question":"What motor types can the ATV600SYSTEM control?","answer":"It supports asynchronous motors with constant torque, variable torque, and optimized torque mode, as well as permanent magnet synchronous motors."},{"question":"What standards does the ATV600SYSTEM comply with?","answer":"It complies with IEC 61800-5-1 (safety), IEC 61800-3 (EMC), IEC 60204-1 (machinery safety), and IEC 61800-2 (adjustable speed drives). Marking is CE."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV600SYSTEM","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV600SYSTEM when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}