{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV630C13N4","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV630C13N4","canonicalUrl":"https://aoctrl.com/schneider/ATV630C13N4","factsUrl":"https://aoctrl.com/api/mcp/products/ATV630C13N4","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV630, ATV630C13N4 variable speed drive, 380-480 V, 132 kW normal duty / 110 kW heavy duty, 250 A continuous output, IP00, CE, active production.","salesMarkdown":"## What this drive is for and what it delivers The ATV630C13N4 is a variable speed drive from the Altivar Process ATV600 series, designed for asynchronous and synchronous motors in process and utilities applications. In heavy duty the continuous output is 211 A at 2.5 kHz, driving 110 kW. Line current draw at full load is 237 A at 380 V normal duty and 213 A at 480 V normal duty; heavy duty figures are 201 A and 165 A respectively. The output frequency range of 0.1 to 500 Hz covers standard induction motors and higher-speed synchronous machines without needing an external frequency multiplier. ## Safety, compliance, and integration Built-in STO (safe torque off) rated SIL 3 per IEC 61508 and EN 13849-1 means this drive can serve in safety circuits up to that integrity level without an external safety relay for the torque-off function. The drive carries CE marking and complies with UL 508C, IEC 61800-3 (environment 1 category C2 and environment 2 category C3), IEC 61800-5-1, IEC 61000-3-12, and IEC 60721-3 — a broad set of North American and international standards that covers most industrial installations. Integrated EMC filter rated for 150 m motor cable in IEC 61800-3 category C3 environments means it meets conducted emission limits for second-environment (industrial) installations without an add-on filter box in most cases. ## Field connections and expansion Onboard communication includes Ethernet, Modbus TCP, and Modbus serial — covers most plant-floor networks without a slot card. For Profibus DP, PROFINET, DeviceNet, EtherNet/IP, CANopen, BACnet MS/TP, or Ethernet Powerlink, a Slot A communication module is required. Eight discrete inputs are provided, with DI7 and DI8 programmable as pulse inputs up to 30 kHz — useful for encoder or flowmeter feedback without an add-on card. The adjustable PID regulator is built in, so closed-loop control for pressure, flow, or level is handled within the drive — no external controller needed for single-loop process regulation. Wall-mount installation with vertical orientation within ±10 degrees; forced convection cooling moves 600 m³/h of air, so enclosure ventilation must be sized to handle that airflow and the 69.9 dB noise level. ## Environmental limits and derating Relative humidity 5...95 % without condensation per IEC 60068-2-3; shock resistance 15 gn for 11 ms; vibration resistance 1.5 mm peak-to-peak at 2-13 Hz and 1 gn at 13-200 Hz — figures that match typical IEC 60068-2-6 and -2-27 levels for panel-mounted gear. Base IP rating is IP00 (open chassis); IP21 is achievable with the VW3A9704 kit — needed if the drive is mounted outside a closed cabinet in a clean indoor environment.","metaTitle":"Schneider Electric ATV630C13N4 Altivar Process VFD","metaDescription":"ATV630C13N4 variable speed drive, 380-480 V, 250 A continuous output, 132 kW normal duty. Active production. CE, UL 508C, IEC 61800-3. STO SIL 3.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"title":"ATV630C13N4","Marking":"CE","Variant":"Standard version","Category":"US1CP4E22207","Standards":"UL 508C IEC 61800-3 IEC 61800-3 environment 1 category C2 EN/IEC 61800-3 environment 2 category C3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1","EMC filter":"Integrated 492.1 ft (150 m) IEC 61800-3 category C3","Noise level":"69.9 dB","Option card":"Slot A communication module, Profibus DP V1 Slot A communication module, PROFINET Slot A communication module, DeviceNet Slot A communication module, Modbus TCP/EtherNet/IP Slot A communication module, CANopen daisy chain RJ45 Slot A communication module, CANopen SUB-D 9 Slot A communication module, CANopen screw terminals Slot A/slot B digital and analog I/O extension module Slot A/slot B output relay extension module Slot A communication module, Ethernet IP/Modbus TCP/MD-Link communication module, BACnet MS/TP communication module, Ethernet Powerlink","description":"Variable Speed Drive, Altivar Process ATV600, ATV630, 130kW, 380 to 480V, IP00","Line current":"237 A 380 V normal duty) 213 A 480 V normal duty) 201 A 380 V heavy duty) 165 A 480 V heavy duty)","Maximum THDI":"<48 % full load IEC 61000-3-12","Mounting Mode":"Wall mount","Motor power kW":"132 kW normal duty) 110 kW heavy duty)","Regulation loop":"Adjustable PID regulator","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2","Range of Product":"Altivar Process ATV600","Shock resistance":"15 gn 11 ms IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV630","Relative humidity":"5...95 % without condensation IEC 60068-2-3","Operating altitude":"1000...4800 m with current derating 1 % per 100 m","Operating position":"Vertical +/- 10 degree","Discrete input type":"DI7, DI8 programmable as pulse input 0...30 kHz, 24 V DC 1 MOhm 500 V DC for 1 minute to earth","Product destination":"Asynchronous motors Synchronous motors","Overvoltage category":"III","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Discrete input number":"8","Nbr. of units in pkg.":"1","Volume of cooling air":"158506.07 Gal/hr(US) (600 m3/h)","Nominal Output Current":"250.0 A","IP degree of protection":"IP00IEC 61800-5-1 IP00IEC 60529 IP21 with kit VW3A9704)IEC 61800-5-1 IP21 with kit VW3A9704)IEC 60529","Continuous output current":"250 A 2.5 kHz normal duty 211 A 2.5 kHz heavy duty","Product or Component Type":"Variable speed drive","[Us] rated supply voltage":"380...480 V","Maximum Horse Power Rating":"200 hp normal duty 150 hp heavy duty","Communication Port Protocol":"Ethernet Modbus TCP Modbus serial","Product Specific Application":"Process and utilities","Speed drive output frequency":"0.1...500 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Ambient air transport temperature":"-40...158 °F (-40...70 °C)","Ambient Air Temperature for Storage":"-40...158 °F (-40...70 °C)","Ambient air temperature for operation":"5...122 °F (-15...50 °C) (without derating) 122...140 °F (50...60 °C) (with derating factor)","Environmental class (during operation)":"Class 3C3 according to IEC 60721-3-3 Class 3S3 according to IEC 60721-3-3","Relative symmetric mains voltage tolerance":"10 %","Permitted relative humidity (during operation)":"Class 3K5 according to EN 60721-3","Relative symmetric network frequency tolerance":"5 %","Maximum acceleration under shock impact (during operation)":"60 m/s² at 11 ms","Maximum deflection under vibratory load (during operation)":"1.5 mm at 2...13 Hz","Maximum acceleration under vibrational stress (during operation)":"10 m/s² at 13...200 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$6,400.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/us/en/product/ATV630C13N4/variable-speed-drive-altivar-process-atv600-atv630-130kw-380-to-480v-ip00/"},"ai":{"faq":[{"question":"What safety functions does ATV630C13N4 include?","answer":"Safe torque off (STO) rated SIL 3 is integrated. No external safety relay is required for the torque-off path in a SIL 3 application, though the rest of the safety loop must still be designed to that integrity level."},{"question":"What compliance documentation does ATV630C13N4 carry?","answer":"CE marking is on the nameplate. The drive is certified to UL 508C, IEC 61800-3 (environments 1 and 2, categories C2 and C3), IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and EN 13849-1. RoHS and REACH compliance is standard for Schneider's current Altivar Process range."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV630C13N4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV630C13N4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}