{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV630C13N4F","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV630C13N4F","canonicalUrl":"https://aoctrl.com/schneider/ATV630C13N4F","factsUrl":"https://aoctrl.com/api/mcp/products/ATV630C13N4F","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV630, ATV630C13N4F, variable speed drive, 132 kW normal duty / 110 kW heavy duty, 380...440 V, 250 A continuous output, IP21, floor-standing.","salesMarkdown":"## 132 kW normal duty at 380–440 V The ATV630C13N4F is a Schneider Electric Altivar Process variable speed drive rated for 132 kW normal duty and 110 kW heavy duty on a 380...440 V supply. It delivers 250 A continuous output at 2.5 kHz for normal duty, and 211 A at the same switching frequency for heavy duty — the derating between duty classes is about 15 %, which matters when the motor load profile is closer to constant torque than variable torque. The output frequency range is 0.1...500 Hz, covering both standard induction motors and higher-speed synchronous machines. Line current at 400 V is 210 A normal duty, 179 A heavy duty; at 380 V it draws 244 A normal, 207 A heavy — the voltage dependency means a weak grid or long feeder run will pull the input current higher than the 400 V nameplate suggests. ## STO SIL 3 and integrated C3 EMC filter Safe torque off (STO) is built in to SIL 3 per IEC 61800-5-2, which eliminates the need for an external safety relay on the power removal path in most guarding circuits. The integrated EMC filter meets category C3 with 150 m of motor cable — that covers the majority of industrial runs without an external output filter, though installations with sensitive equipment on the same bus may still need an input line reactor. Total harmonic current distortion (THDI) is below 48 % at full load per IEC 61000-3-12, which is the standard for equipment connected to the public low-voltage network above 16 A per phase. The drive also carries CE marking and complies with IEC 60204-1, IEC 61800-2, IEC 61800-3, and IEC 61800-5-1 — the full machinery directive stack for variable-speed drives in Europe. ## Floor-standing with forced convection, 720 m³/h This is a floor-standing unit (IP21 per IEC 61800-5-1 and IEC 60529), not a panel-mount or wall-mount drive. The forced-convection cooling moves 720 m³/h of air, so the installation space needs clear intake and exhaust paths — stacking enclosures or tight corners will recirculate hot air and trigger thermal derating. Operating altitude is 1000 m base with 1 % derating per 100 m above that, up to 4800 m. Ambient temperature range is -15 to 40 °C without derating, and up to 50 °C with a derating factor applied. ## Communication slot architecture and PID control Slot A accepts fieldbus option cards: Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, CANopen (daisy chain RJ45, SUB-D 9, or screw terminals), and Ethernet Powerlink. Slot A and slot B also accept digital/analog I/O extension modules and output relay extension modules. The base communication ports are Ethernet, Modbus serial, and Modbus TCP — so the drive ships network-ready for most plant-floor architectures without an option card. An adjustable PID regulator is built into the regulation loop, which means the drive can close a process loop (pressure, flow, level) directly without a separate controller. The 8 discrete inputs include two that are programmable as pulse inputs up to 30 kHz, useful for encoder or flowmeter feedback.","metaTitle":"Schneider ATV630C13N4F Altivar Process Drive, 132 kW","metaDescription":"Schneider Electric ATV630C13N4F Altivar Process variable speed drive, 132 kW normal duty, 380-440 V, 250 A continuous output, IP21, STO SIL 3. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"title":"ATV630C13N4F","Marking":"CE","Variant":"Standard version","Standards":"IEC 60204-1 IEC 61800-2 IEC 61800-3 IEC 61800-5-1","EMC filter":"Integrated with 150 m conforming to IEC 61800-3 category C3","Noise level":"69 dB","Option card":"Slot A: communication module, Profibus DP V1 Slot A: communication module, PROFINET Slot A: communication module, DeviceNet Slot A: communication module, Modbus TCP/EtherNet/IP Slot A: communication module, CANopen daisy chain RJ45 Slot A: communication module, CANopen SUB-D 9 Slot A: communication module, CANopen screw terminals Slot A/slot B: digital and analog I/O extension module Slot A/slot B: output relay extension module Slot A: communication module, Ethernet IP/Modbus TCP/MD-Link Communication module, BACnet MS/TP Communication module, Ethernet Powerlink","description":"variable speed drive, Altivar Process ATV600, ATV630, 132kW, 380 to 440V, IP21","Line current":"210 A at 400 V (normal duty) 179 A at 400 V (heavy duty) 244 A at 380 V (normal duty) 207 A at 380 V (heavy duty)","Maximum THDI":"<48 % full load conforming to IEC 61000-3-12","Mounting mode":"Floor-standing","Motor power kW":"132 kW (normal duty) 110 kW (heavy duty)","Regulation loop":"Adjustable PID regulator","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2","Range of product":"Altivar Process ATV600","Shock resistance":"15 gn for 11 ms conforming to IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV630","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Operating altitude":"1000...4800 m with current derating 1 % per 100 m","Operating position":"Vertical +/- 10 degree","Discrete input type":"DI7, DI8 programmable as pulse input: 0...30 kHz, 24 V DC ( 1 MOhm 500 V DC for 1 minute to earth","Product destination":"Asynchronous motors Synchronous motors","Overvoltage category":"III","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Discrete input number":"8","Volume of cooling air":"720 m3/h","Nominal Output Current":"250.0 A","IP degree of protection":"IP21 conforming to IEC 61800-5-1 IP21 conforming to IEC 60529","Continuous output current":"250 A at 2.5 kHz for normal duty 211 A at 2.5 kHz for heavy duty","Product or component type":"Variable speed drive","[Us] rated supply voltage":"380...440 V","Communication port protocol":"Ethernet Modbus serial Modbus TCP","Product specific application":"Process and utilities","Speed drive output frequency":"0.1...500 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Ambient air transport temperature":"-25...70 °C","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"-15...40 °C (without derating) 40...50 °C (with derating factor)","Environmental class (during operation)":"Class 3C3 according to IEC 60721-3-3 Class 3S3 according to IEC 60721-3-3","Relative symmetric mains voltage tolerance":"10 %","Permitted relative humidity (during operation)":"Class 3K5 according to EN 60721-3","Relative symmetric network frequency tolerance":"5 %","Maximum acceleration under shock impact (during operation)":"40 m/s² at 11 ms","Maximum deflection under vibratory load (during operation)":"1.5 mm at 2...13 Hz","Maximum acceleration under vibrational stress (during operation)":"6 m/s² at 13...200 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$17,677.92","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ie/en/product/ATV630C13N4F/variable-speed-drive-altivar-process-atv600-atv630-132kw-380-to-440v-ip21/"},"ai":{"faq":[{"question":"What compliance documentation does Schneider provide for ATV630C13N4F?","answer":"The drive carries CE marking and complies with IEC 60204-1, IEC 61800-2, IEC 61800-3, and IEC 61800-5-1. The integrated EMC filter meets IEC 61800-3 category C3 with 150 m of motor cable. THDI is below 48 % at full load per IEC 61000-3-12. STO is certified to SIL 3 per IEC 61800-5-2. Standard documentation includes the EU declaration of conformity and the installation manual."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV630C13N4F","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV630C13N4F when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}