{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV630C25N4428","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV630C25N4428","canonicalUrl":"https://aoctrl.com/schneider/ATV630C25N4428","factsUrl":"https://aoctrl.com/api/mcp/products/ATV630C25N4428","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV630, ATV630C25N4428, AC drive, 250 kW / 400 hp normal duty, 481 A continuous output, 380-480 V, IP00, wall mount.","salesMarkdown":"## Active production — what that means for procurement The ATV630C25N4428: The part carries CE marking and complies with UL 508C, IEC 61800-3, and IEC 61800-5-1, which covers the documentation a compliance team needs for panel certification. ## Motor power and output current — sizing the drive to the load Rated 250 kW (400 hp) for normal-duty applications and 220 kW (300 hp) for heavy-duty cycles, this Altivar Process drive is sized for medium-voltage motor control in process and utilities environments — pumps, fans, compressors, and conveyors that run continuously or under variable torque. Continuous output current is 481 A at a 2.5 kHz switching frequency for normal duty, and 387 A at 2.5 kHz for heavy duty. The 481 A figure is the headline rating — it governs the motor full-load current the drive can deliver without derating. For applications requiring higher switching frequencies (quieter motor operation), the output current must be derated per the drive's thermal model. Line current draw is 451 A at 380 V (normal duty) and 366 A at 480 V (normal duty). The supply voltage range is 380...480 V at 50/60 Hz, which covers standard global industrial mains. The integrated EMC filter meets IEC 61800-3 category C3 for 50 m cable runs — suitable for most industrial installations without external filtering. ## Safety and control integration This simplifies the control panel wiring and reduces component count in a guarding application. The drive accepts communication modules via Slot A: Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, CANopen, and Ethernet Powerlink. Native Modbus serial and Ethernet ports are onboard. This fieldbus flexibility lets the ATV630 slot into existing automation architectures — whether the plant runs on a legacy Profibus network or a modern EtherNet/IP line. Eight discrete inputs are provided, with DI7 and DI8 programmable as pulse inputs up to 30 kHz. An adjustable PID regulator is built in, so the drive can close a loop on pressure, flow, or level without an external controller — a common requirement in pumping and HVAC applications. ## Environmental ratings and mounting constraints IP00 as standard — the drive is open-frame and intended for installation inside an electrical enclosure. An IP21 kit (VW3A9113) is available for environments where drip protection is needed. Wall-mount only; operating position must be vertical within ±10 degrees. Forced convection cooling moves 1260 m³/h of air, so clearance around the heatsink is non-negotiable in the panel layout. Vibration resistance is 1.5 mm peak-to-peak at 2–13 Hz and 1 gn at 13–200 Hz per IEC 60068-2-6. Shock resistance is 15 gn for 11 ms per IEC 60068-2-27. Noise level is 76 dB — relevant if the drive is installed in a noise-sensitive area. Relative humidity range is 5...95 % without condensation per IEC 60068-2-3.","metaTitle":"Schneider Electric ATV630C25N4428 AC Drive, 250 kW, 481 A","metaDescription":"Schneider Electric ATV630C25N4428 Altivar Process AC drive, 250 kW normal duty, 481 A continuous output. Active production, sourced per RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"title":"ATV630C25N4428","Marking":"CE","Variant":"Standard version","Standards":"UL 508C IEC 61800-3 IEC 61800-3 environment 1 category C2 EN/IEC 61800-3 environment 2 category C3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1","EMC filter":"Integrated with 50 m conforming to IEC 61800-3 category C3","Noise level":"76 dB","Option card":"Slot A: communication module, Profibus DP V1 Slot A: communication module, PROFINET Slot A: communication module, DeviceNet Slot A: communication module, Modbus TCP/EtherNet/IP Slot A: communication module, CANopen daisy chain RJ45 Slot A: communication module, CANopen SUB-D 9 Slot A: communication module, CANopen screw terminals Slot A/slot B: digital and analog I/O extension module Slot A/slot B: output relay extension module Slot A: communication module, Ethernet IP/Modbus TCP/MD-Link Communication module, BACnet MS/TP Communication module, Ethernet Powerlink","description":"variable speed drive, Altivar Process ATV600, ATV630, 250kW, 400hp, 380...480V, IP00, marine certification","Line current":"451 A at 380 V (normal duty) 366 A at 480 V (normal duty) 365 A at 380 V (heavy duty) 301 A at 480 V (heavy duty)","Maximum THDI":"<48 % full load conforming to IEC 61000-3-12","Mounting mode":"Wall mount","Motor power hp":"400 hp normal duty 300 hp heavy duty","Motor power kW":"250 kW (normal duty) 220 kW (heavy duty)","Regulation loop":"Adjustable PID regulator","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2","Range of product":"Altivar Process ATV600","Shock resistance":"15 gn for 11 ms conforming to IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV630","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Operating altitude":"1000...3000 m with current derating 1 % per 100 m","Operating position":"Vertical +/- 10 degree","Discrete input type":"DI7, DI8 programmable as pulse input: 0...30 kHz, 24 V DC ( 1 MOhm 500 V DC for 1 minute to earth","Product destination":"Asynchronous motors Synchronous motors","Overvoltage category":"III","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Discrete input number":"8","Volume of cooling air":"1260 m3/h","Nominal Output Current":"481.0 A","IP degree of protection":"IP00 conforming to IEC 61800-5-1 IP00 conforming to IEC 60529 IP21 (with kit VW3A9113) conforming to IEC 61800-5-1 IP21 (with kit VW3A9113) conforming to IEC 60529","Continuous output current":"481 A at 2.5 kHz for normal duty 387 A at 2.5 kHz for heavy duty","Product or component type":"Variable speed drive","[Us] rated supply voltage":"380...480 V","Communication port protocol":"Modbus TCP Modbus serial Ethernet","Product specific application":"Process and utilities","Speed drive output frequency":"0.1...500 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Ambient air transport temperature":"-40...70 °C","Ambient air temperature for storage":"-25...70 °C","Ambient air temperature for operation":"-10...40 °C (without derating) 40...60 °C (with derating factor)","Environmental class (during operation)":"Class 3C3 according to IEC 60721-3-3 Class 3S3 according to IEC 60721-3-3","Relative symmetric mains voltage tolerance":"10 %","Permitted relative humidity (during operation)":"Class 3K5 according to EN 60721-3","Relative symmetric network frequency tolerance":"5 %","Maximum acceleration under shock impact (during operation)":"60 m/s² at 11 ms","Maximum deflection under vibratory load (during operation)":"1.5 mm at 2...13 Hz","Maximum acceleration under vibrational stress (during operation)":"10 m/s² at 13...200 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/sg/en/product/ATV630C25N4428/variable-speed-drive-altivar-process-atv600-atv630-250kw-400hp-380-480v-ip00-marine-certification/"},"ai":{"faq":[{"question":"What compliance documentation does the ATV630C25N4428 carry?","answer":"CE marked, UL 508C listed, and compliant with IEC 61800-3 (EMC environments 1 category C2 and 2 category C3), IEC 61800-5-1 (safety), IEC 61000-3-12 (harmonic), IEC 60721-3 (environmental), IEC 61508 and IEC 13849-1 (functional safety). The integrated EMC filter meets category C3 for 50 m cable runs."},{"question":"What is the closest alternative to the ATV630C25N4428 in the Altivar Process family?","answer":"Within the ATV630 series, the closest sibling is the next-lower or next-higher current rating at the same voltage class. The ATV630C25N4428 is the 250 kW normal-duty variant at 380-480 V. A parametric match would require the same frame size, supply voltage, and communication slot configuration — confirm the motor full-load current and the required switching frequency before selecting an adjacent rating."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV630C25N4428","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV630C25N4428 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}