{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV630D11N4SW","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV630D11N4SW","canonicalUrl":"https://aoctrl.com/schneider/ATV630D11N4SW","factsUrl":"https://aoctrl.com/api/mcp/products/ATV630D11N4SW","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV630 variable speed drive, 11 kW / 15 hp normal duty, 7.5 kW / 10 hp heavy duty, 380-480 V, 23.5 A continuous output, IP21, STO SIL 3, standard version.","salesMarkdown":"The ATV630D11N4SW is a standard-variant Altivar Process drive rated 11 kW (15 hp) for normal duty and 7.5 kW (10 hp) for heavy duty, fed from a 380-480 V three-phase supply. The normal-duty current is 23.5 A continuous at 4 kHz carrier, which is the figure to use when sizing the input breaker and motor cable for a centrifugal pump or fan load. Heavy-duty current drops to 16.5 A at 4 kHz — that is the rating for constant-torque loads like a screw conveyor or extruder where the drive must deliver full torque down to zero speed. The integrated EMC filter is rated for 50 m of motor cable at category C2 (first environment, residential/commercial) and 150 m at category C3 (second environment, industrial). That means for most industrial panel builds you can run 150 m of shielded cable without an external filter, which saves panel space and installation cost. The filter is built in, not an add-on option card. This is the safety function that removes torque-producing power from the motor without disconnecting the mains — it is the standard interface for integrating the drive into a safety circuit with a safety PLC or safety relay. The STO input is dual-channel and must be wired to a certified safety output. IP21 protection means the drive is drip-proof but not hose-down rated — it belongs in a clean, dry indoor enclosure. The wall-mount format requires vertical orientation within ±10° and clearance around the forced-convection cooling fan that moves 103 m³/h of air. Pollution degree 2 (non-conductive, occasional condensation) matches typical control-room or electrical-room conditions. For a drive installed at 2000 m, budget 10% less continuous current — the heavy-duty figure drops from 16.5 A to about 14.9 A. The ambient temperature range is not explicitly stated in the spec table, but the forced-convection cooling and 56 dB noise level suggest a standard 40-50 °C ambient ceiling typical for this class. The drive carries UL 508C listing and UL Type 1 enclosure rating, so it can be installed in a UL-compliant panel without an additional enclosure for indoor use. ## I/O, communications, and expansion slots Eight discrete inputs are onboard, with DI7 and DI8 programmable as pulse inputs up to 30 kHz — useful for connecting an encoder or flowmeter directly without an external pulse divider. The adjustable PID regulator is built in, so for a simple pressure or flow control loop you do not need an external process controller; set the setpoint and gains in the drive parameters. Onboard communication ports are Modbus TCP, Ethernet, and Modbus serial — the standard suite for most plant-floor networks. Slot A accepts a fieldbus option card for Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, CANopen (three connector variants), or Ethernet Powerlink. Slot A and slot B also accept digital/analog I/O extension or output relay extension modules. This means the drive can be ordered as a base unit and the communication interface added later without changing the drive order code. The drive is compatible with both asynchronous (induction) and synchronous (PM) motors, so it can be used with a retrofit of an existing induction motor or a new high-efficiency PM motor. Output frequency range is 0.1 to 500 Hz, covering standard 50/60 Hz motors and high-speed spindles up to 30,000 rpm (for a 4-pole motor). The standard variant means this is the base configurable drive, not a pre-configured or application-specific version. If the BOM calls for a specific fieldbus or I/O configuration, the option card is ordered separately and installed in slot A or slot B. No pin-compatible direct alternative exists within the ATV630 family — the order code defines the power stage and enclosure size; a different power rating requires a different order code.","metaTitle":"Schneider ATV630D11N4SW AC Drive, 11 kW/15 hp, 380-480 V","metaDescription":"Schneider Electric ATV630D11N4SW Altivar Process drive, 11 kW normal duty / 7.5 kW heavy duty, 380-480 V, IP21, STO SIL 3, integrated EMC filter.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Marking":"CE","Variant":"Standard version","Standards":"UL 508C IEC 61800-3 IEC 61800-3 environment 1 category C2 EN/IEC 61800-3 environment 2 category C3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1","EMC filter":"Integrated with 50 m conforming to IEC 61800-3 category C2 Integrated with 150 m conforming to IEC 61800-3 category C3","Noise level":"56 dB","Option card":"Slot A: communication module, Profibus DP V1 Slot A: communication module, PROFINET Slot A: communication module, DeviceNet Slot A: communication module, Modbus TCP/EtherNet/IP Slot A: communication module, CANopen daisy chain RJ45 Slot A: communication module, CANopen SUB-D 9 Slot A: communication module, CANopen screw terminals Slot A/slot B: digital and analog I/O extension module Slot A/slot B: output relay extension module Slot A: communication module, Ethernet IP/Modbus TCP/MD-Link Communication module, BACnet MS/TP Communication module, Ethernet Powerlink","Line current":"19.8 A at 380 V (normal duty) 17 A at 480 V (normal duty) 14.1 A at 380 V (heavy duty) 12.5 A at 480 V (heavy duty)","Maximum THDI":"<48 % from 80...100 % of load conforming to IEC 61000-3-12","Mounting mode":"Wall mount","Motor power hp":"15 hp normal duty 10 hp heavy duty","Motor power kW":"11 kW (normal duty) 7.5 kW (heavy duty)","Regulation loop":"Adjustable PID regulator","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2","Range of product":"Altivar Process ATV600","Shock resistance":"15 gn for 11 ms conforming to IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV630","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Operating altitude":"1000...4800 m with current derating 1 % per 100 m","Operating position":"Vertical +/- 10 degree","Discrete input type":"DI7, DI8 programmable as pulse input: 0...30 kHz, 24 V DC ( 1 MOhm 500 V DC for 1 minute to earth","Product destination":"Asynchronous motors Synchronous motors","Degree of protection":"UL type 1 conforming to UL 508C","Overvoltage category":"III","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Discrete input number":"8","Volume of cooling air":"103 m3/h","Nominal Output Current":"23.5 A","IP degree of protection":"IP21 conforming to IEC 61800-5-1 IP21 conforming to IEC 60529","Continuous output current":"23.5 A at 4 kHz for normal duty 16.5 A at 4 kHz for heavy duty","Product or component type":"Variable speed drive","[Us] rated supply voltage":"380...480 V","Communication port protocol":"Modbus TCP Ethernet Modbus serial","Product specific application":"Process and utilities","Speed drive output frequency":"0.1...500 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Ambient air transport temperature":"-40...70 °C","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"-15...50 °C (without derating) 50...60 °C (with derating factor)","Environmental class (during operation)":"Class 3C3 according to IEC 60721-3-3 Class 3S3 according to IEC 60721-3-3","Relative symmetric mains voltage tolerance":"10 %","Permitted relative humidity (during operation)":"Class 3K5 according to EN 60721-3","Relative symmetric network frequency tolerance":"5 %","Maximum acceleration under shock impact (during operation)":"150 m/s² at 11 ms","Maximum deflection under vibratory load (during operation)":"1.5 mm at 2...13 Hz","Maximum acceleration under vibrational stress (during operation)":"10 m/s² at 13...200 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ae/en/product/ATV630D11N4SW/variable-speed-drive-atv630-ip21-11kw-400v-480v/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ATV630D11N4SW/alternatives.json"},"ai":{"faq":[{"question":"What is the ATV630D11N4SW used for?","answer":"This variable speed drive is designed for process and utility applications — primarily pumps, fans, compressors, and conveyors. It controls the speed of both asynchronous (induction) and synchronous (PM) motors from 0.1 to 500 Hz. The built-in PID regulator makes it suitable for closed-loop control of pressure, flow, or level without an external controller."},{"question":"What safety functions does the ATV630D11N4SW include?","answer":"STO removes torque-producing power from the motor without disconnecting the mains supply, and it is the standard interface for integrating the drive into a safety circuit with a safety PLC or safety relay."},{"question":"What communication protocols are supported on the ATV630D11N4SW?","answer":"Onboard communication includes Modbus TCP, Ethernet, and Modbus serial. Slot A accepts option cards for Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, CANopen (three connector variants), or Ethernet Powerlink. Slot A and slot B also accept digital/analog I/O extension or output relay extension modules."},{"question":"Where can I buy the ATV630D11N4SW and how is it quoted?","answer":"The ATV630D11N4SW is sourced through authorized Schneider Electric distribution channels. No stock-holding claim is made; each order is confirmed against the distributor's inventory and the manufacturer's production schedule."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV630D11N4SW","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV630D11N4SW when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}