{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV630U07M3US","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV630U07M3US","canonicalUrl":"https://aoctrl.com/schneider/ATV630U07M3US","factsUrl":"https://aoctrl.com/api/mcp/products/ATV630U07M3US","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV630, variable speed drive, 200-240 V, 0.75 kW normal duty, IP21, STO safety function, current production.","salesMarkdown":"## Drive profile and sourcing posture The Schneider Electric ATV630U07M3US is an Altivar Process variable speed drive rated for 200-240 V supply, delivering 0.75 kW normal duty or 0.37 kW heavy duty. Continuous output current is 4.6 A at 4 kHz for normal duty, 3.3 A for heavy duty. IP21 enclosure with UL type 1 listing. Current production – this part is active and sourced to order. Motor power selection: heavy-duty rating (0.37 kW) is the correct figure for constant-torque loads like conveyors and positive-displacement pumps; normal-duty (0.75 kW) applies to variable-torque fans and centrifugal pumps. The heavy-duty current of 3.3 A limits the inverter output at 4 kHz, so if your motor draws more than that at full load, step up to the next frame. STO (safe torque off) to SIL 3 allows integration into a safety circuit without an external safety relay for the drive-enable path. Communication flexibility: Slot A accepts Profibus DP V1, PROFINET, DeviceNet, CANopen, Modbus TCP/EtherNet/IP, and Ethernet Powerlink modules – use the specific module that matches your controller. Base drive includes Modbus serial and Ethernet for service/commissioning. EMC filter is omitted (Without EMC filter), so an external filter is required for compliance with IEC 61800-3 environment 1 or 2 if the drive is installed in a residential or industrial mains network with sensitive equipment. ## Installation and environmental constraints Wall-mount only, vertical ±10°. Forced-convection cooling requires 38 m³/h airflow; maintain clearance around the heatsink. Operating altitude up to 1000 m without derating, then 1% current derating per 100 m to 4800 m. Ambient temperature range not stated – assume standard 0-50°C unless datasheet specifies otherwise. Discrete inputs: 8 total, DI7 and DI8 programmable as pulse inputs up to 30 kHz. At 24 V DC, 1 MΩ input impedance. Optical isolation? Not specified, but isolation test voltage is 500 V DC to earth for 1 minute. Use shielded cable for pulse inputs. Vibration resistance to IEC 60068-2-6: 1 gn at 13-200 Hz, 1.5 mm peak-peak at 2-13 Hz. ## Compliance documentation Carries CE marking and meets standards UL 508C, IEC 61800-3 (environment 1 category C2, environment 2 category C3), IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, IEC 13849-1. TAA/BAA compliant via COTS; current production.","metaTitle":"Schneider ATV630U07M3US Altivar Process Drive, 0.75kW, STO,","metaDescription":"Schneider Electric ATV630U07M3US variable speed drive, 200-240V, 0.75kW normal duty, STO SIL3, IP21. Current production. Sourced to order. Request RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 240V"],"specifications":{"title":"ATV630U07M3US","Marking":"CE","Variant":"Standard version","Category":"US1CP4E22205","Standards":"UL 508C IEC 61800-3 IEC 61800-3 environment 1 category C2 EN/IEC 61800-3 environment 2 category C3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1","EMC filter":"Without EMC filter","Noise level":"54.5 dB","Option card":"Slot A communication module, Profibus DP V1 Slot A communication module, PROFINET Slot A communication module, DeviceNet Slot A communication module, Modbus TCP/EtherNet/IP Slot A communication module, CANopen daisy chain RJ45 Slot A communication module, CANopen SUB-D 9 Slot A communication module, CANopen screw terminals Slot A/slot B digital and analog I/O extension module Slot A/slot B output relay extension module Slot A communication module, Ethernet IP/Modbus TCP/MD-Link communication module, BACnet MS/TP communication module, Ethernet Powerlink","description":"Variable Speed Drive, Altivar Process ATV600, ATV630, 0.75kW, 1hp, 200 to 240V, IP21, UL type 1 [TAA, BAA, BABA]","Line current":"3 A 200 V normal duty) 2.6 A 240 V normal duty) 1.7 A 200 V heavy duty) 1.5 A 240 V heavy duty)","Maximum THDI":"<48 % full load IEC 61000-3-12","Mounting Mode":"Wall mount","Motor power kW":"0.75 kW normal duty) 0.37 kW heavy duty)","Regulation loop":"Adjustable PID regulator","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2","Range of Product":"Altivar Process ATV600","Shock resistance":"15 gn 11 ms IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV630","Relative humidity":"5...95 % without condensation IEC 60068-2-3","Operating altitude":"1000...4800 m with current derating 1 % per 100 m","Operating position":"Vertical +/- 10 degree","Discrete input type":"DI7, DI8 programmable as pulse input 0...30 kHz, 24 V DC 1 MOhm 500 V DC for 1 minute to earth","Product destination":"Asynchronous motors Synchronous motors","Degree of protection":"UL type 1 UL 508C","Overvoltage category":"III","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Compliance/Compliance":"TAA BAA BABA BAA via COTS","Discrete input number":"8","Nbr. of units in pkg.":"1","Volume of cooling air":"10038.7 Gal/hr(US) (38 m3/h)","Nominal Output Current":"4.6 A","IP degree of protection":"IP21IEC 61800-5-1 IP21IEC 60529","Continuous output current":"4.6 A 4 kHz normal duty 3.3 A 4 kHz heavy duty","Product or Component Type":"Variable speed drive","[Us] rated supply voltage":"200...240 V","Maximum Horse Power Rating":"1 hp normal duty 0.5 hp heavy duty","Communication Port Protocol":"Modbus TCP Modbus serial Ethernet","Product Specific Application":"Process and utilities","Speed drive output frequency":"0.1...500 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Ambient air transport temperature":"-40...158 °F (-40...70 °C)","Ambient Air Temperature for Storage":"-40...158 °F (-40...70 °C)","Ambient air temperature for operation":"5...122 °F (-15...50 °C) (without derating) 122...140 °F (50...60 °C) (with derating factor)","Environmental class (during operation)":"Class 3C3 according to IEC 60721-3-3 Class 3S3 according to IEC 60721-3-3","Relative symmetric mains voltage tolerance":"10 %","Permitted relative humidity (during operation)":"Class 3K5 according to EN 60721-3","Relative symmetric network frequency tolerance":"5 %","Maximum acceleration under shock impact (during operation)":"150 m/s² at 11 ms","Maximum deflection under vibratory load (during operation)":"1.5 mm at 2...13 Hz","Maximum acceleration under vibrational stress (during operation)":"10 m/s² at 13...200 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,591.85","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/14d43e5864162dcbe53b64195f4d2821.pdf","sourceUrl":"https://www.se.com/us/en/product/ATV630U07M3US/variable-speed-drive-altivar-process-atv600-atv630-0-75kw-1hp-200-to-240v-ip21-ul-type-1-taa-baa-baba/"},"ai":{"faq":[{"question":"What is the CE marking on this drive?","answer":"The drive carries CE marking as per the specification."},{"question":"What are the key compliance standards for this drive?","answer":"UL 508C, IEC 61800-3 (environment 1 category C2, environment 2 category C3), IEC 61800-5-1, IEC 61800-5-2 (STO), IEC 61000-3-12, IEC 60721-3, IEC 61508, IEC 13849-1. Also TAA/BAA compliant."},{"question":"What is the variant of this part?","answer":"Standard version."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV630U07M3US","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV630U07M3US when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}