{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV630U22N4Z","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV630U22N4Z","canonicalUrl":"https://aoctrl.com/schneider/ATV630U22N4Z","factsUrl":"https://aoctrl.com/api/mcp/products/ATV630U22N4Z","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV630, standard version, variable speed drive, 2.2 kW normal duty / 1.5 kW heavy duty, 380...480 V, 5.6 A nominal output, IP20, cabinet mount.","salesMarkdown":"The Schneider ATV630U22N4Z is a standard version Altivar Process ATV630 variable speed drive sized for a 2.2 kW normal-duty or 1.5 kW heavy-duty motor on a 380...480 V three-phase supply. Nominal output current is 5.6 A; continuous output at 4 kHz switching is 5.6 A for normal duty and 4 A for heavy duty. Output frequency range is 0.1...500 Hz, covering both asynchronous and synchronous motors. The integrated EMC filter meets IEC 61800-3 Category C2 at 10 m cable and Category C3 at 50 m cable (with optional EMC plate), which simplifies panel layout for most industrial environments without an external filter. Safe Torque Off (STO) is built in at SIL 3, so this drive can serve in safety circuits up to that level without an external safety relay for the stop function. ## Panel integration checklist Cabinet mount with a finned heatsink; forced convection cooling moves 38 m³/h of air. Mount vertically within ±10° of plumb. IP20 enclosure means it lives inside a panel — no washdown exposure, but fine for clean dry cabinets. Operating altitude up to 1000 m full rating, then derate 1% per 100 m to 4800 m. ## Fieldbus and I/O layout Slot A accepts a range of communication option cards: Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, CANopen (RJ45, SUB-D 9, or screw terminals), Ethernet IP/Modbus TCP/MD-Link, BACnet MS/TP, and Ethernet Powerlink. Slot A/B also accepts digital/analog I/O extension and output relay extension modules. Onboard communication includes Modbus TCP, Modbus serial, and Ethernet. Eight discrete inputs are standard; DI7 and DI8 can be programmed as pulse inputs up to 30 kHz. An adjustable PID regulator is built in for process control loops. CE marked. Certified to UL 508C, IEC 61800-3 (environments 1 category C2 and 2 category C3), IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1. EMC immunity tested to level 3 for electrostatic discharge, radiated RF, and conducted RF; level 4 for electrical fast transient/burst.","metaTitle":"Schneider ATV630U22N4Z Altivar Process Drive, 2.2 kW, 380-48","metaDescription":"Schneider ATV630U22N4Z variable speed drive, 2.2 kW normal duty, 380-480 V, IP20, STO SIL 3, integrated EMC filter. Current lifecycle stage. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"title":"ATV630U22N4Z","Marking":"CE","Variant":"Standard version","Standards":"UL 508C IEC 61800-3 IEC 61800-3 environment 1 category C2 EN/IEC 61800-3 environment 2 category C3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1","EMC filter":"Integrated 32.8 ft (10 m) IEC 61800-3 category C2 Integrated 164.04 ft (50 m) IEC 61800-3 category C3 With EMC plate option","Noise level":"54.5 dB","Option card":"Slot A communication module, Profibus DP V1 Slot A communication module, PROFINET Slot A communication module, DeviceNet Slot A communication module, Modbus TCP/EtherNet/IP Slot A communication module, CANopen daisy chain RJ45 Slot A communication module, CANopen SUB-D 9 Slot A communication module, CANopen screw terminals Slot A/slot B digital and analog I/O extension module Slot A/slot B output relay extension module Slot A communication module, Ethernet IP/Modbus TCP/MD-Link communication module, BACnet MS/TP communication module, Ethernet Powerlink","description":"variable speed drive, Altivar Process ATV600, ATV630, cabinet Integration, IP20, 2,2kW, 380 to 480 V","Line current":"4.3 A 380 V normal duty) 3.8 A 480 V normal duty) 3.1 A 380 V heavy duty) 2.9 A 480 V heavy duty)","Maximum THDI":"<48 % full load IEC 61000-3-12","Mounting Mode":"Cabinet mount","Assembly style":"With heat sink","Motor power kW":"2.2 kW normal duty) 1.5 kW heavy duty)","Regulation loop":"Adjustable PID regulator","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"2","Range of Product":"Altivar Process ATV600","Shock resistance":"15 gn 11 ms IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV630","Relative humidity":"5...95 % without condensation IEC 60068-2-3","Operating altitude":"1000...4800 m with current derating 1 % per 100 m","Operating position":"Vertical +/- 10 degree","Discrete input type":"DI7, DI8 programmable as pulse input 0...30 kHz, 24 V DC 1 MOhm 500 V DC for 1 minute to earth","Product destination":"Asynchronous motors Synchronous motors","Overvoltage category":"III","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Discrete input number":"8","Nbr. of units in pkg.":"1","Volume of cooling air":"10038.7 Gal/hr(US) (38 m3/h)","Nominal Output Current":"5.6 A","IP degree of protection":"IP20IEC 61800-5-1 IP20IEC 60529","Continuous output current":"5.6 A 4 kHz normal duty 4 A 4 kHz heavy duty","Product or Component Type":"Variable speed drive","[Us] rated supply voltage":"380...480 V","Maximum Horse Power Rating":"3 hp normal duty 2 hp heavy duty","Communication Port Protocol":"Modbus TCP Modbus serial Ethernet","Product Specific Application":"Process and utilities","Speed drive output frequency":"0.1...500 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Ambient air transport temperature":"-40...158 °F (-40...70 °C)","Ambient Air Temperature for Storage":"-40...158 °F (-40...70 °C)","Ambient air temperature for operation":"5...122 °F (-15...50 °C) (without derating) 122...140 °F (50...60 °C) (with derating factor)","Environmental class (during operation)":"Class 3C3 according to IEC 60721-3-3 Class 3S3 according to IEC 60721-3-3","Relative symmetric mains voltage tolerance":"10 %","Permitted relative humidity (during operation)":"Class 3K5 according to EN 60721-3","Relative symmetric network frequency tolerance":"5 %","Maximum acceleration under shock impact (during operation)":"150 m/s² at 11 ms","Maximum deflection under vibratory load (during operation)":"1.5 mm at 2...13 Hz","Maximum acceleration under vibrational stress (during operation)":"10 m/s² at 13...200 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/23ef9decece6a71cfeb2c27befe5737d.pdf","sourceUrl":"https://www.se.com/us/en/product/ATV630U22N4Z/variable-speed-drive-altivar-process-atv600-atv630-cabinet-integration-ip20-22kw-380-to-480-v/"},"ai":{"faq":[{"question":"What are the key power ratings for this drive?","answer":"Normal duty: 2.2 kW at 5.6 A continuous output. Heavy duty: 1.5 kW at 4 A continuous output. Supply voltage is 380...480 V three-phase."},{"question":"What safety functions does this drive include?","answer":"Safe Torque Off (STO) rated SIL 3 per IEC 61508 and IEC 13849-1 is integrated."},{"question":"What fieldbus options are available?","answer":"Slot A accepts Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, CANopen (three connector variants), Ethernet IP/Modbus TCP/MD-Link, BACnet MS/TP, and Ethernet Powerlink modules. Onboard protocols are Modbus TCP, Modbus serial, and Ethernet."},{"question":"What EMC filter is integrated?","answer":"The integrated filter meets IEC 61800-3 Category C2 with 10 m cable and Category C3 with 50 m cable (with optional EMC plate)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV630U22N4Z","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV630U22N4Z when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}