{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV650C16N4F","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV650C16N4F","canonicalUrl":"https://aoctrl.com/schneider/ATV650C16N4F","factsUrl":"https://aoctrl.com/api/mcp/products/ATV650C16N4F","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV600 series, ATV650C16N4F variable speed drive, 380-440 V supply, 160 kW normal duty / 132 kW heavy duty, 302 A continuous output, IP54, floor-standing with integrated disconnect switch.","salesMarkdown":"## 160 kW process drive with integrated disconnect The ATV650C16N4F is a floor-standing Altivar Process ATV600 drive rated for 160 kW normal duty and 132 kW heavy duty on asynchronous or synchronous motors, supplied at 380-440 V, 50/60 Hz. It delivers 302 A continuous output at 2.5 kHz switching for normal duty, 250 A for heavy duty. The integrated disconnect switch (variant feature) means this unit arrives with the line-side isolation already built in — one less component to panel-mount and wire, and a cleaner fault-isolation path for the field service tech pulling the drive for swap-out. ## IP54 enclosure and cooling for floor-standing install IP54 per IEC 60529 and IEC 61800-5-1, with forced-convection cooling moving 720 m³/h of air. The enclosure rating suits indoor installations where dust and splash are present — pump houses, water treatment, light industrial process areas — without needing a separate cabinet. Mount vertical within ±10°. Operating ambient is -15 to 40 °C without derating, up to 50 °C with derating. Altitude derating starts at 1000 m: 1 % per 100 m above that, up to 4800 m. ## STO SIL 3 and EMC with 150 m cable reach Safe Torque Off (STO) rated SIL 3 per IEC 61800-5-2 is standard — no separate safety module needed for the drive's own torque removal. The integrated EMC filter meets IEC 61800-3 category C3 with 150 m motor cable, and total harmonic current distortion (THDI) stays below 48 % at full load per IEC 61000-3-12. Compliance base includes IEC 60204-1, IEC 61800-2, IEC 61800-3, and IEC 61800-5-1. CE marking on the nameplate covers the EU regulatory scope. Shock rated 15 gn for 11 ms. ## Fieldbus slot and I/O complement Slot A accepts communication modules for PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, CANopen (daisy chain RJ45, SUB-D 9, or screw terminals), Profibus DP V1, Ethernet Powerlink, BACnet MS/TP, and Ethernet IP/Modbus TCP/MD-Link. Slot A and slot B also accept digital/analog I/O extension and output relay extension modules. Native Modbus serial and Modbus TCP are on the base unit. Eight discrete inputs are standard, with DI7 and DI8 programmable as pulse inputs up to 30 kHz. An adjustable PID regulator is built in for closed-loop process control — pressure, flow, level, temperature — without an external controller.","metaTitle":"Schneider Electric ATV650C16N4F AC Drive, 160 kW ND, 302 A","metaDescription":"Schneider Electric ATV650C16N4F Altivar Process ATV600 drive, 160 kW normal duty, 302 A output, IP54 with disconnect switch. CE marked, STO SIL 3.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"title":"ATV650C16N4F","Marking":"CE","Variant":"With disconnect switch","Standards":"IEC 60204-1 IEC 61800-2 IEC 61800-3 IEC 61800-5-1","EMC filter":"Integrated with 150 m conforming to IEC 61800-3 category C3","Noise level":"69 dB","Option card":"Slot A: communication module, PROFINET Slot A: communication module, DeviceNet Slot A: communication module, Modbus TCP/EtherNet/IP Slot A: communication module, CANopen daisy chain RJ45 Slot A: communication module, CANopen SUB-D 9 Slot A: communication module, CANopen screw terminals Slot A/slot B: digital and analog I/O extension module Slot A/slot B: output relay extension module Slot A: communication module, Ethernet IP/Modbus TCP/MD-Link Communication module, BACnet MS/TP Communication module, Ethernet Powerlink Slot A: communication module, Profibus DP V1","description":"variable speed drive, Altivar Process ATV600, ATV650, 160kW, 400 to 480V, floor standing","Line current":"251 A at 400 V (heavy duty) 210 A at 380 V (normal duty) 291 A at 380 V (heavy duty) 244 A at 400 V (normal duty)","Maximum THDI":"<48 % full load conforming to IEC 61000-3-12","Mounting mode":"Floor-standing","Motor power kW":"160 kW (normal duty) 132 kW (heavy duty)","Regulation loop":"Adjustable PID regulator","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"3","Range of product":"Altivar Process ATV600","Shock resistance":"15 gn for 11 ms conforming to IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV650","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Operating altitude":"1000...4800 m with current derating 1 % per 100 m <= 1000 m without derating","Operating position":"Vertical +/- 10 degree","Discrete input type":"DI7, DI8 programmable as pulse input: 0...30 kHz, 24 V DC ( 1 MOhm 500 V DC for 1 minute to earth","Product destination":"Asynchronous motors Synchronous motors","Overvoltage category":"III","Vibration resistance":"1 gn (f= 13...200 Hz) conforming to IEC 60068-2-6 1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6","Discrete input number":"8","Volume of cooling air":"720 m3/h","Nominal Output Current":"302.0 A","IP degree of protection":"IP54 conforming to IEC 60529 IP54 conforming to IEC 61800-5-1","Continuous output current":"302 A at 2.5 kHz for normal duty 250 A at 2.5 kHz for heavy duty","Product or component type":"Variable speed drive","[Us] rated supply voltage":"380...440 V","Communication port protocol":"Modbus TCP Modbus serial Modbus serial","Product specific application":"Process and utilities","Speed drive output frequency":"0.1...500 Hz","Electromagnetic compatibility":"Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2","Ambient air transport temperature":"-25...70 °C","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"40...50 °C (with derating factor) -15...40 °C (without derating)","Environmental class (during operation)":"Class 3C3 according to IEC 60721-3-3 Class 3S3 according to IEC 60721-3-3","Relative symmetric mains voltage tolerance":"10 %","Permitted relative humidity (during operation)":"Class 3K5 according to EN 60721-3","Relative symmetric network frequency tolerance":"5 %","Maximum acceleration under shock impact (during operation)":"40 m/s² at 11 ms","Maximum deflection under vibratory load (during operation)":"1.5 mm at 2...13 Hz","Maximum acceleration under vibrational stress (during operation)":"6 m/s² at 13...200 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/ie/en/product/download-pdf/ATV650C16N4F?filename=Schneider+Electric_Altivar-Process-ATV600_ATV650C16N4F.pdf', 'path_name': 'aaa408c707ba1fce99ec09136f25de54.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/aaa408c707ba1fce99ec09136f25de54.pdf', 'status': 1}","sourceUrl":"https://www.se.com/ie/en/product/ATV650C16N4F/variable-speed-drive-altivar-process-atv600-atv650-160kw-400-to-480v-floor-standing/"},"ai":{"faq":[{"question":"Where can I buy the ATV650C16N4F and get a price?","answer":"The ATV650C16N4F is sourced through independent distribution channels."},{"question":"What is the ATV650C16N4F's IP rating and cooling method?","answer":"IP54 per IEC 60529 and IEC 61800-5-1, with forced-convection cooling. The enclosure is rated for dust and splash protection in indoor industrial environments."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV650C16N4F","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV650C16N4F when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}