{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV650C20N4F","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV650C20N4F","canonicalUrl":"https://aoctrl.com/schneider/ATV650C20N4F","factsUrl":"https://aoctrl.com/api/mcp/products/ATV650C20N4F","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV650C20N4F variable speed drive, 380-440 V, 200 kW normal duty / 160 kW heavy duty, 370 A continuous output, IP54, with disconnect switch, STO SIL 3.","salesMarkdown":"## Process drive with built-in disconnect The ATV650C20N4F is a floor-standing Altivar Process ATV600 series drive rated for 200 kW normal duty and 160 kW heavy duty on asynchronous or synchronous motors. The variant includes an integrated disconnect switch, which simplifies panel wiring by eliminating a separate upstream disconnecting means. Supply voltage is 380...440 V at 50/60 Hz. Continuous output current is 370 A at 2.5 kHz for normal duty and 302 A at 2.5 kHz for heavy duty, with line current draw up to 369 A at 380 V heavy duty. ## Safety, EMC, and environmental ratings An integrated EMC filter meets IEC 61800-3 category C3 with up to 150 m of motor cable, so external filtering is not needed for most industrial installations. Enclosure is IP54 per IEC 60529 and IEC 61800-5-1, suitable for floor-standing installation in areas with dust and splash exposure. Pollution degree 3, overvoltage category III, and vibration resistance to IEC 60068-2-6 (1 gn at 13-200 Hz) cover typical industrial environments. Operating temperature range is -15 to 40 °C without derating, extending to 50 °C with derating. Total harmonic current distortion (THDI) is below 48% at full load per IEC 61000-3-12, which helps meet plant power-quality limits without a separate line reactor in many cases. ## Fieldbus, I/O, and commissioning flexibility Slot A accepts communication modules for PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, CANopen (daisy chain RJ45, SUB-D 9, or screw terminals), Profibus DP V1, Ethernet Powerlink, and BACnet MS/TP. Slot A and slot B also accept digital/analog I/O extension and output relay extension modules. Eight discrete inputs are provided, with DI7 and DI8 programmable as pulse inputs up to 30 kHz. Built-in Modbus serial and Ethernet Modbus TCP are standard. The adjustable PID regulator supports closed-loop process control without an external controller. Output frequency range is 0.1 to 500 Hz.","metaTitle":"Schneider ATV650C20N4F AC Drive, 200 kW, 370 A, IP54, STO","metaDescription":"Schneider Electric ATV650C20N4F Altivar Process drive, 200 kW normal duty / 160 kW heavy duty, 370 A continuous output, IP54, STO SIL 3, integrated disconnect.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"title":"ATV650C20N4F","Marking":"CE","Variant":"With disconnect switch","Standards":"IEC 61800-3 EN/IEC 61800-3 environment 2 category C3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 UL 508C","EMC filter":"Integrated with 150 m conforming to IEC 61800-3 category C3","Noise level":"70 dB","Option card":"Slot A: communication module, PROFINET Slot A: communication module, DeviceNet Slot A: communication module, Modbus TCP/EtherNet/IP Slot A: communication module, CANopen daisy chain RJ45 Slot A: communication module, CANopen SUB-D 9 Slot A: communication module, CANopen screw terminals Slot A/slot B: digital and analog I/O extension module Slot A/slot B: output relay extension module Slot A: communication module, Ethernet IP/Modbus TCP/MD-Link Communication module, BACnet MS/TP Communication module, Ethernet Powerlink Slot A: communication module, Profibus DP V1","description":"variable speed drive ATV650 - 200kW - 380...440V - IP54 - disconnect switch","Line current":"319 A at 400 V (heavy duty) 262 A at 380 V (normal duty) 369 A at 380 V (heavy duty) 302 A at 400 V (normal duty)","Maximum THDI":"<48 % full load conforming to IEC 61000-3-12","Mounting mode":"Floor-standing","Motor power kW":"200 kW (normal duty) 160 kW (heavy duty)","Regulation loop":"Adjustable PID regulator","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"3","Range of product":"Altivar Process ATV600","Shock resistance":"15 gn for 11 ms conforming to IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV650","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Operating altitude":"1000...4800 m with current derating 1 % per 100 m <= 1000 m without derating","Operating position":"Vertical +/- 10 degree","Discrete input type":"DI7, DI8 programmable as pulse input: 0...30 kHz, 24 V DC ( 1 MOhm 500 V DC for 1 minute to earth","Product destination":"Asynchronous motors Synchronous motors","Overvoltage category":"III","Vibration resistance":"1 gn (f= 13...200 Hz) conforming to IEC 60068-2-6 1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6","Discrete input number":"8","Volume of cooling air":"1300 m3/h","Nominal Output Current":"370.0 A","IP degree of protection":"IP54 conforming to IEC 60529 IP54 conforming to IEC 61800-5-1","Continuous output current":"370 A at 2.5 kHz for normal duty 302 A at 2.5 kHz for heavy duty","Product or component type":"Variable speed drive","[Us] rated supply voltage":"380...440 V","Communication port protocol":"Ethernet Modbus TCP Modbus serial","Product specific application":"Process and utilities","Speed drive output frequency":"0.1...500 Hz","Electromagnetic compatibility":"Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2","Ambient air transport temperature":"-25...70 °C","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"40...50 °C (with derating factor) -15...40 °C (without derating)","Environmental class (during operation)":"Class 3C3 according to IEC 60721-3-3 Class 3S3 according to IEC 60721-3-3","Relative symmetric mains voltage tolerance":"10 %","Permitted relative humidity (during operation)":"Class 3K5 according to EN 60721-3","Relative symmetric network frequency tolerance":"5 %","Maximum acceleration under shock impact (during operation)":"40 m/s² at 11 ms","Maximum deflection under vibratory load (during operation)":"1.5 mm at 2...13 Hz","Maximum acceleration under vibrational stress (during operation)":"6 m/s² at 13...200 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/ae/en/product/download-pdf/ATV650C20N4F?filename=Schneider+Electric_Altivar-Process-ATV600_ATV650C20N4F.pdf', 'path_name': '1d020749c37d1c9c1c3c9af95f57eeae.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/1d020749c37d1c9c1c3c9af95f57eeae.pdf', 'status': 1}","sourceUrl":"https://www.se.com/ae/en/product/ATV650C20N4F/variable-speed-drive-atv650-200kw-380-440v-ip54-disconnect-switch/"},"ai":{"faq":[{"question":"What is the closest alternative to ATV650C20N4F in the Altivar Process family?","answer":"The ATV650C20N4F is the specific variant with an integrated disconnect switch. A functionally similar drive without the disconnect would be a standard ATV660 or ATV680 of the same power class, but the disconnect variant is a distinct order code — no direct pin-compatible drop-in exists. Confirm the BOM position before substituting."},{"question":"What compliance documentation does Schneider Electric provide for ATV650C20N4F?","answer":"The drive carries CE marking and complies with IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, IEC 13849-1, and UL 508C. Standards for EMC immunity include IEC 61000-4-2, -3, -4, -5, and -6 at test level 3 or 4. RoHS and REACH documentation is available from Schneider Electric on request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV650C20N4F","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV650C20N4F when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}