{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV650D45N4","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV650D45N4","canonicalUrl":"https://aoctrl.com/schneider/ATV650D45N4","factsUrl":"https://aoctrl.com/api/mcp/products/ATV650D45N4","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV650 series, ATV650D45N4 variable speed drive, 60 hp normal duty / 50 hp heavy duty, 380-480 V, 88.0 A nominal output, IP55, wall mount, integrated EMC filter, STO SIL 3 safety function.","salesMarkdown":"## 60 hp process drive in an IP55 wall-mount package The ATV650D45N4 is a 60 hp normal duty / 50 hp heavy duty variable speed drive from Schneider Electric's Altivar Process ATV600 series, designed for pumps, fans, compressors, and conveyors in process and utilities applications. It delivers 88.0 A nominal output current from a 380-480 V three-phase supply, with continuous output of 87 A at 4 kHz for normal duty and 59 A at 4 kHz for heavy duty. The IP55 enclosure (per IEC 60529 and IEC 61800-5-1) makes it suitable for washdown areas and dusty industrial environments without needing a separate enclosure. Wall mount orientation with vertical ±10° tolerance ensures proper forced-convection cooling airflow. ## Integrated EMC filter and harmonic compliance for grid connection The drive ships with an integrated EMC filter that covers 50 m motor cable runs to IEC 61800-3 category C2 (restricted distribution) and 150 m runs to category C3 (industrial environment). This eliminates the need for an external filter in most industrial installations, saving panel space and wiring time. Total harmonic current distortion (THDI) is below 48 % from 80 to 100 % load, complying with IEC 61000-3-12 for connection to the public low-voltage grid. ## STO SIL 3 safety function and flexible I/O for process control Safe Torque Off (STO) integrated to SIL 3 per IEC 61508 and EN/IEC 13849-1 means the drive can safely remove torque from the motor without an external safety relay — a critical spare for lines where safety circuit downtime is expensive. The adjustable PID regulator enables closed-loop control of pressure, flow, or level directly from the drive. Eight discrete inputs are available, with DI7 and DI8 programmable as 0-30 kHz pulse inputs for encoder feedback or flow meter signals. Slot A accepts seven communication module options including PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, CANopen, Profibus DP V1, and Ethernet Powerlink; Slot A/B also accepts digital/analog I/O and relay extension modules. ## Active production — sourced per RFQ against your BOM The drive carries CE marking and complies with UL 508C, IEC 61800-5-1, IEC 61800-3, IEC 61508, and EN/IEC 13849-1. Altitude derating starts above 1000 m at 1 % per 100 m up to 4800 m.","metaTitle":"Schneider ATV650D45N4 AC Drive, 60 hp, 480 V, IP55","metaDescription":"Schneider Electric ATV650D45N4 Altivar Process VFD, 60 hp normal duty / 50 hp heavy duty, 380-480 V, IP55, integrated EMC filter, STO SIL 3.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"title":"ATV650D45N4","Marking":"CE","Variant":"Standard version","Standards":"IEC 61800-3 IEC 61800-3 environment 1 category C2 EN/IEC 61800-3 environment 2 category C3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 UL 508C","EMC filter":"Integrated with 50 m conforming to IEC 61800-3 category C2 Integrated with 150 m conforming to IEC 61800-3 category C3","Noise level":"69.7 dB","Option card":"Slot A: communication module, PROFINET Slot A: communication module, DeviceNet Slot A: communication module, Modbus TCP/EtherNet/IP Slot A: communication module, CANopen daisy chain RJ45 Slot A: communication module, CANopen SUB-D 9 Slot A: communication module, CANopen screw terminals Slot A/slot B: digital and analog I/O extension module Slot A/slot B: output relay extension module Slot A: communication module, Ethernet IP/Modbus TCP/MD-Link Communication module, BACnet MS/TP Communication module, Ethernet Powerlink Slot A: communication module, Profibus DP V1","description":"variable speed drive ATV650 - 45kW/60HP - 380...480V - IP55","Line current":"57.3 A at 480 V (normal duty) 54.8 A at 380 V (heavy duty) 48.3 A at 480 V (heavy duty) 79.8 A at 380 V (normal duty)","Maximum THDI":"<48 % from 80...100 % of load conforming to IEC 61000-3-12","Mounting mode":"Wall mount","Motor power hp":"50 hp heavy duty 60 hp normal duty","Motor power kW":"37 kW (heavy duty) 45 kW (normal duty)","Regulation loop":"Adjustable PID regulator","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"3","Range of product":"Altivar Process ATV600","Shock resistance":"15 gn for 11 ms conforming to IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV650","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Operating altitude":"1000...4800 m with current derating 1 % per 100 m <= 1000 m without derating","Operating position":"Vertical +/- 10 degree","Discrete input type":"DI7, DI8 programmable as pulse input: 0...30 kHz, 24 V DC ( 1 MOhm 500 V DC for 1 minute to earth","Product destination":"Asynchronous motors Synchronous motors","Overvoltage category":"III","Vibration resistance":"1 gn (f= 13...200 Hz) conforming to IEC 60068-2-6 1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6","Discrete input number":"8","Nominal Output Current":"88.0 A","IP degree of protection":"IP55 conforming to IEC 60529 IP55 conforming to IEC 61800-5-1","Continuous output current":"59 A at 4 kHz for heavy duty 87 A at 4 kHz for normal duty","Product or component type":"Variable speed drive","[Us] rated supply voltage":"380...480 V","Communication port protocol":"Ethernet Modbus TCP","Product specific application":"Process and utilities","Speed drive output frequency":"0.1...500 Hz","Electromagnetic compatibility":"Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2","Ambient air transport temperature":"-40...70 °C","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"40...50 °C (with derating factor) -15...40 °C (without derating)","Environmental class (during operation)":"Class 3C3 according to IEC 60721-3-3 Class 3S3 according to IEC 60721-3-3","Relative symmetric mains voltage tolerance":"10 %","Permitted relative humidity (during operation)":"Class 3K5 according to EN 60721-3","Relative symmetric network frequency tolerance":"5 %","Maximum acceleration under shock impact (during operation)":"150 m/s² at 11 ms","Maximum deflection under vibratory load (during operation)":"1.5 mm at 2...13 Hz","Maximum acceleration under vibrational stress (during operation)":"10 m/s² at 13...200 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/ae/en/product/download-pdf/ATV650D45N4?filename=Schneider+Electric_Altivar-Process-ATV600_ATV650D45N4.pdf', 'path_name': 'aa0f0b37e5054627e0ff808bfe63d954.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/aa0f0b37e5054627e0ff808bfe63d954.pdf', 'status': 1}","sourceUrl":"https://www.se.com/ae/en/product/ATV650D45N4/variable-speed-drive-atv650-45kw-60hp-380-480v-ip55/"},"ai":{"faq":[{"question":"What communication protocols does this drive support?","answer":"Slot A accepts PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, CANopen (daisy chain RJ45, SUB-D 9, or screw terminals), Profibus DP V1, Ethernet Powerlink, and Ethernet IP/Modbus TCP/MD-Link. The drive also has standard Ethernet Modbus TCP onboard. Slot A/B accepts digital/analog I/O and relay extension modules."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV650D45N4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV650D45N4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}