{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV650D45N4E","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV650D45N4E","canonicalUrl":"https://aoctrl.com/schneider/ATV650D45N4E","factsUrl":"https://aoctrl.com/api/mcp/products/ATV650D45N4E","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV600 series, ATV650D45N4E variable speed drive, 45 kW / 60 hp normal duty, 380-480 V, 87 A continuous output at 4 kHz, IP55, wall mount, with disconnect switch.","salesMarkdown":"## Process drive with integrated disconnect The ATV650D45N4E is a 45 kW normal-duty / 37 kW heavy-duty variable speed drive from the Altivar Process ATV600 family, built for pump, fan, compressor, and conveyor applications in water, HVAC, and light industrial settings. It ships with a factory-integrated disconnect switch, which means the drive can be locked out for maintenance without an external isolator — a time-saver on panel builds and a clear safety upgrade for the line-side electrician. ## Output current and duty ratings at 4 kHz carrier Continuous output current is 87 A at 4 kHz for normal duty and 72 A at 4 kHz for heavy duty. The 4 kHz carrier is the default; raising it quiets motor whine but derates the available current — the 87 A figure is the ceiling for sizing the motor cable and the upstream protection. Line current draw ranges from 59 A (heavy duty at 480 V) to 79.8 A (normal duty at 380 V). That spread matters when sizing the feeder breaker and the incoming cable — the 380 V case pulls the higher amps, so the branch circuit should be rated for the normal-duty 380 V figure. Rated supply voltage is 380-480 V, 50/60 Hz. The drive handles the full range without a tap change, which simplifies stocking for plants with mixed line voltages. ## IP55 enclosure and environmental tolerance IP55 per IEC 60529 and IEC 61800-5-1 means the enclosure is dust-protected and can handle water jets from any direction — suitable for washdown areas, outdoor installations under a roof, or floor-mount near process equipment. Operating temperature range is -15 to 40 °C without derating, extending to 50 °C with a derating factor. The forced-convection cooling needs clearance around the heatsink; wall-mount orientation vertical ±10° is the only approved position. Altitude derating starts above 1000 m: 1 % current reduction per 100 m up to 4800 m. For a plant at 2000 m elevation, budget a 10 % current headroom on the motor side. ## Safety, EMC, and fieldbus options STO (Safe Torque Off) is integrated at SIL 3 per IEC 61508 and PL e per ISO 13849-1. No external safety relay needed for the stop function — the drive accepts the safety signal directly on its control terminals. The integrated EMC filter supports 50 m of motor cable at Category C2 and 150 m at Category C3. For a CE-marked installation with a long motor run, the C3 limit is the one to design to. Slot A accepts fieldbus option cards: PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, CANopen (daisy chain RJ45, SUB-D 9, or screw terminals), Profibus DP V1, Ethernet Powerlink, and BACnet MS/TP. Slot A and Slot B also accept digital/analog I/O extension and output relay extension modules.","metaTitle":"Schneider Electric ATV650D45N4E Altivar Process VFD, 45 kW","metaDescription":"Schneider Electric ATV650D45N4E Altivar Process ATV600 drive, 45 kW (60 hp) normal duty, 380-480 V, IP55, integrated disconnect switch, STO SIL 3.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Current":"69.1 A at 480 V (normal duty) 67.1 A at 380 V (heavy duty) 59 A at 480 V (heavy duty) 79.8 A at 380 V (normal duty)","Frequency":"50...60 Hz - 5...5 %","IP Rating":"IP55","Horsepower":"50 hp heavy duty 60 hp normal duty","Product Status":"Active","Pollution Degree":"3","Temp Storage Max":"70 °C","Temp Storage Min":"-40 °C","Operating Position":"Vertical +/- 10 degree","Temp Operating Max":"70 °C","Temp Operating Min":"-40 °C","Temperature Storage":"-40...70 °C","Main Product Or Component Type":"Variable speed drive","Ambient Air Temperature Operation":"40...50 °C (with derating factor) -15...40 °C (without derating)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ie/en/product/ATV650D45N4E/variable-speed-drive-altivar-process-atv600-atv650-45kw-400-to-480v-ip55-disconnect-switch/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ATV650D45N4E/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV650D45N4E","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV650D45N4E when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}