{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV650D45N4E","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV650D45N4E","canonicalUrl":"https://aoctrl.com/schneider/ATV650D45N4E","factsUrl":"https://aoctrl.com/api/mcp/products/ATV650D45N4E","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV600 series, ATV650D45N4E variable speed drive, 45 kW / 60 hp normal duty, 380-480 V, 87 A continuous output at 4 kHz, IP55, wall mount, with disconnect switch.","salesMarkdown":"## Process drive with integrated disconnect The ATV650D45N4E is a 45 kW normal-duty / 37 kW heavy-duty variable speed drive from the Altivar Process ATV600 family, built for pump, fan, compressor, and conveyor applications in water, HVAC, and light industrial settings. It ships with a factory-integrated disconnect switch, which means the drive can be locked out for maintenance without an external isolator — a time-saver on panel builds and a clear safety upgrade for the line-side electrician. ## Output current and duty ratings at 4 kHz carrier Continuous output current is 87 A at 4 kHz for normal duty and 72 A at 4 kHz for heavy duty. The 4 kHz carrier is the default; raising it quiets motor whine but derates the available current — the 87 A figure is the ceiling for sizing the motor cable and the upstream protection. Line current draw ranges from 59 A (heavy duty at 480 V) to 79.8 A (normal duty at 380 V). That spread matters when sizing the feeder breaker and the incoming cable — the 380 V case pulls the higher amps, so the branch circuit should be rated for the normal-duty 380 V figure. Rated supply voltage is 380-480 V, 50/60 Hz. The drive handles the full range without a tap change, which simplifies stocking for plants with mixed line voltages. ## IP55 enclosure and environmental tolerance IP55 per IEC 60529 and IEC 61800-5-1 means the enclosure is dust-protected and can handle water jets from any direction — suitable for washdown areas, outdoor installations under a roof, or floor-mount near process equipment. Operating temperature range is -15 to 40 °C without derating, extending to 50 °C with a derating factor. The forced-convection cooling needs clearance around the heatsink; wall-mount orientation vertical ±10° is the only approved position. Altitude derating starts above 1000 m: 1 % current reduction per 100 m up to 4800 m. For a plant at 2000 m elevation, budget a 10 % current headroom on the motor side. ## Safety, EMC, and fieldbus options STO (Safe Torque Off) is integrated at SIL 3 per IEC 61508 and PL e per ISO 13849-1. No external safety relay needed for the stop function — the drive accepts the safety signal directly on its control terminals. The integrated EMC filter supports 50 m of motor cable at Category C2 and 150 m at Category C3. For a CE-marked installation with a long motor run, the C3 limit is the one to design to. Slot A accepts fieldbus option cards: PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, CANopen (daisy chain RJ45, SUB-D 9, or screw terminals), Profibus DP V1, Ethernet Powerlink, and BACnet MS/TP. Slot A and Slot B also accept digital/analog I/O extension and output relay extension modules.","metaTitle":"Schneider Electric ATV650D45N4E Altivar Process VFD, 45 kW","metaDescription":"Schneider Electric ATV650D45N4E Altivar Process ATV600 drive, 45 kW (60 hp) normal duty, 380-480 V, IP55, integrated disconnect switch, STO SIL 3.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"title":"ATV650D45N4E","Marking":"CE","Variant":"With disconnect switch","Standards":"IEC 61800-3 IEC 61800-3 environment 1 category C2 EN/IEC 61800-3 environment 2 category C3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1","EMC filter":"Integrated with 50 m conforming to IEC 61800-3 category C2 Integrated with 150 m conforming to IEC 61800-3 category C3","Noise level":"69.7 dB","Option card":"Slot A: communication module, PROFINET Slot A: communication module, DeviceNet Slot A: communication module, Modbus TCP/EtherNet/IP Slot A: communication module, CANopen daisy chain RJ45 Slot A: communication module, CANopen SUB-D 9 Slot A: communication module, CANopen screw terminals Slot A/slot B: digital and analog I/O extension module Slot A/slot B: output relay extension module Slot A: communication module, Ethernet IP/Modbus TCP/MD-Link Communication module, BACnet MS/TP Communication module, Ethernet Powerlink Slot A: communication module, Profibus DP V1","description":"variable speed drive, Altivar Process ATV600, ATV650, 45kW, 400 to 480V, IP55, disconnect switch","Line current":"69.1 A at 480 V (normal duty) 67.1 A at 380 V (heavy duty) 59 A at 480 V (heavy duty) 79.8 A at 380 V (normal duty)","Maximum THDI":"<48 % from 80...100 % of load conforming to IEC 61000-3-12","Mounting mode":"Wall mount","Motor power hp":"50 hp heavy duty 60 hp normal duty","Motor power kW":"37 kW (heavy duty) 45 kW (normal duty)","Regulation loop":"Adjustable PID regulator","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"3","Range of product":"Altivar Process ATV600","Shock resistance":"15 gn for 11 ms conforming to IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV650","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Operating altitude":"1000...4800 m with current derating 1 % per 100 m <= 1000 m without derating","Operating position":"Vertical +/- 10 degree","Discrete input type":"DI7, DI8 programmable as pulse input: 0...30 kHz, 24 V DC ( 1 MOhm 500 V DC for 1 minute to earth","Product destination":"Asynchronous motors Synchronous motors","Overvoltage category":"III","Vibration resistance":"1 gn (f= 13...200 Hz) conforming to IEC 60068-2-6 1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6","Discrete input number":"8","Nominal Output Current":"88.0 A","IP degree of protection":"IP55 conforming to IEC 60529 IP55 conforming to IEC 61800-5-1","Continuous output current":"72 A at 4 kHz for heavy duty 87 A at 4 kHz for normal duty","Product or component type":"Variable speed drive","[Us] rated supply voltage":"380...480 V","Communication port protocol":"Modbus serial Ethernet Modbus TCP","Product specific application":"Process and utilities","Speed drive output frequency":"0.1...500 Hz","Electromagnetic compatibility":"Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2","Ambient air transport temperature":"-40...70 °C","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"40...50 °C (with derating factor) -15...40 °C (without derating)","Environmental class (during operation)":"Class 3C3 according to IEC 60721-3-3 Class 3S3 according to IEC 60721-3-3","Relative symmetric mains voltage tolerance":"10 %","Permitted relative humidity (during operation)":"Class 3K5 according to EN 60721-3","Relative symmetric network frequency tolerance":"5 %","Maximum acceleration under shock impact (during operation)":"150 m/s² at 11 ms","Maximum deflection under vibratory load (during operation)":"1.5 mm at 2...13 Hz","Maximum acceleration under vibrational stress (during operation)":"10 m/s² at 13...200 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/ie/en/product/download-pdf/ATV650D45N4E?filename=Schneider+Electric_Altivar-Process-ATV600_ATV650D45N4E.pdf', 'path_name': '5762b4bc2a8c11c4a453d065c51c5bf4.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/5762b4bc2a8c11c4a453d065c51c5bf4.pdf', 'status': 1}","sourceUrl":"https://www.se.com/ie/en/product/ATV650D45N4E/variable-speed-drive-altivar-process-atv600-atv650-45kw-400-to-480v-ip55-disconnect-switch/"},"ai":{"faq":[{"question":"How can I order ATV650D45N4E and get a quote?","answer":"The ATV650D45N4E is quoted to order against your BOM quantity."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV650D45N4E","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV650D45N4E when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}