{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV650D75N4E","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV650D75N4E","canonicalUrl":"https://aoctrl.com/schneider/ATV650D75N4E","factsUrl":"https://aoctrl.com/api/mcp/products/ATV650D75N4E","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV650D75N4E variable speed drive, 75 kW heavy duty / 100 hp normal duty, 380-480 V, 145 A nominal output, IP55, with integrated disconnect switch.","salesMarkdown":"## Active production — what that means for your BOM line The ATV650D75N4E: This drive carries CE marking and complies with IEC 61800-3, IEC 61800-5-1, IEC 61508, and IEC 13849-1 — covering both EMC and functional safety for European installations. ## Motor power and duty ratings — sizing the drive to the load Rated 75 kW heavy duty and 100 hp normal duty, this drive handles asynchronous and synchronous motors. The heavy-duty rating is the one to use for constant-torque loads like conveyors or extruders; the normal-duty figure applies for variable-torque centrifugal pumps and fans. Continuous output current is 106 A at 2.5 kHz for heavy duty and 145 A at 2.5 kHz for normal duty. The nominal output current is 145.0 A. Line current varies by supply voltage and duty: 112.7 A at 480 V normal duty, 98.9 A at 380 V heavy duty. ## Built-in disconnect switch and IP55 — panel integration notes The variant with disconnect switch means the drive includes an integrated load-break switch on the input, simplifying panel wiring and meeting local isolation requirements without a separate external disconnect. IP55 protection (conforming to IEC 60529 and IEC 61800-5-1) allows wall-mount installation in washdown areas or dusty environments — no need for a separate enclosure in most process plant locations. Mounting position is vertical ±10 degrees. Ambient temperature range is -15 to 40 °C without derating, and up to 50 °C with derating. Above 1000 m altitude, derate current 1 % per 100 m up to 4800 m. Forced convection cooling; noise level is 69.9 dB. ## Safety function and communication slots Integrated STO (Safe Torque Off) rated SIL 3 per IEC 61508 — this is the safety function that removes torque from the motor without a separate contactor. It's the primary safety interface for hazard zones on a process line. Slot A accepts communication modules for PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, CANopen (daisy chain RJ45, SUB-D 9, or screw terminals), Profibus DP V1, Ethernet Powerlink, and BACnet MS/TP. Slot A and slot B also accept digital/analog I/O extension and output relay extension modules. The drive ships with Ethernet, Modbus serial, and Modbus TCP as standard communication ports. ## EMC filter and harmonic performance Integrated EMC filter rated for 150 m cable length in category C3 environment (IEC 61800-3 environment 2, category C3). This means the drive is suitable for industrial power networks where the supply impedance is low — typical for factory floor installations. Maximum THDI is <48 % from 80-100 % load per IEC 61000-3-12.","metaTitle":"Schneider Electric ATV650D75N4E Altivar Process drive","metaDescription":"Schneider Electric ATV650D75N4E variable speed drive, 75 kW heavy duty / 100 hp normal duty, 380-480 V, IP55, with disconnect switch.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"title":"ATV650D75N4E","Marking":"CE","Variant":"With disconnect switch","Standards":"IEC 61800-3 IEC 61800-3 environment 1 category C2 EN/IEC 61800-3 environment 2 category C3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1","EMC filter":"Integrated with 150 m conforming to IEC 61800-3 category C3","Noise level":"69.9 dB","Option card":"Slot A: communication module, PROFINET Slot A: communication module, DeviceNet Slot A: communication module, Modbus TCP/EtherNet/IP Slot A: communication module, CANopen daisy chain RJ45 Slot A: communication module, CANopen SUB-D 9 Slot A: communication module, CANopen screw terminals Slot A/slot B: digital and analog I/O extension module Slot A/slot B: output relay extension module Slot A: communication module, Ethernet IP/Modbus TCP/MD-Link Communication module, BACnet MS/TP Communication module, Ethernet Powerlink Slot A: communication module, Profibus DP V1","description":"variable speed drive, Altivar Process ATV600, ATV650, 75kW, 400 to 480V, IP55, disconnect switch","Line current":"112.7 A at 480 V (normal duty) 98.9 A at 380 V (heavy duty) 86.9 A at 480 V (heavy duty) 131.3 A at 380 V (normal duty)","Maximum THDI":"<48 % from 80...100 % of load conforming to IEC 61000-3-12","Mounting mode":"Wall mount","Motor power hp":"75 hp heavy duty 100 hp normal duty","Motor power kW":"55 kW (heavy duty) 75 kW (normal duty)","Regulation loop":"Adjustable PID regulator","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"3","Range of product":"Altivar Process ATV600","Shock resistance":"15 gn for 11 ms conforming to IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV650","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Operating altitude":"1000...4800 m with current derating 1 % per 100 m <= 1000 m without derating","Operating position":"Vertical +/- 10 degree","Discrete input type":"DI7, DI8 programmable as pulse input: 0...30 kHz, 24 V DC ( 1 MOhm 500 V DC for 1 minute to earth","Product destination":"Asynchronous motors Synchronous motors","Overvoltage category":"III","Vibration resistance":"1 gn (f= 13...200 Hz) conforming to IEC 60068-2-6 1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6","Discrete input number":"8","Nominal Output Current":"145.0 A","IP degree of protection":"IP55 conforming to IEC 60529 IP55 conforming to IEC 61800-5-1","Continuous output current":"106 A at 2.5 kHz for heavy duty 145 A at 2.5 kHz for normal duty","Product or component type":"Variable speed drive","[Us] rated supply voltage":"380...480 V","Communication port protocol":"Ethernet Modbus serial Modbus TCP","Product specific application":"Process and utilities","Speed drive output frequency":"0.1...500 Hz","Electromagnetic compatibility":"Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2","Ambient air transport temperature":"-40...70 °C","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"40...50 °C (with derating factor) -15...40 °C (without derating)","Environmental class (during operation)":"Class 3C3 according to IEC 60721-3-3 Class 3S3 according to IEC 60721-3-3","Relative symmetric mains voltage tolerance":"10 %","Permitted relative humidity (during operation)":"Class 3K5 according to EN 60721-3","Relative symmetric network frequency tolerance":"5 %","Maximum acceleration under shock impact (during operation)":"150 m/s² at 11 ms","Maximum deflection under vibratory load (during operation)":"1.5 mm at 2...13 Hz","Maximum acceleration under vibrational stress (during operation)":"10 m/s² at 13...200 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/ie/en/product/download-pdf/ATV650D75N4E?filename=Schneider+Electric_Altivar-Process-ATV600_ATV650D75N4E.pdf', 'path_name': '2c26c54efa0385b01c85960f1eb8ad2c.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/2c26c54efa0385b01c85960f1eb8ad2c.pdf', 'status': 1}","sourceUrl":"https://www.se.com/ie/en/product/ATV650D75N4E/variable-speed-drive-altivar-process-atv600-atv650-75kw-400-to-480v-ip55-disconnect-switch/"},"ai":{"faq":[{"question":"What compliance documentation does Schneider Electric provide for ATV650D75N4E?","answer":"The drive carries CE marking and complies with IEC 61800-3 (EMC), IEC 61800-5-1 (safety), IEC 61508 (functional safety, STO SIL 3), IEC 13849-1, IEC 61000-3-12 (harmonics), IEC 60721-3 (environmental), and IEC 60068-2-27/2-6 (shock/vibration). Pollution degree 3, overvoltage category III. Standard documentation includes the CE declaration of conformity and the product manual."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV650D75N4E","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV650D75N4E when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}