{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV650U15N4EU","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV650U15N4EU","canonicalUrl":"https://aoctrl.com/schneider/ATV650U15N4EU","factsUrl":"https://aoctrl.com/api/mcp/products/ATV650U15N4EU","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV600 series, ATV650U15N4EU, 0.75 kW heavy duty / 1.5 kW normal duty, 380-480 V, IP55, with disconnect switch.","salesMarkdown":"## Sourcing Reality – Active Production, No LTB Pressure This drive includes a factory-integrated disconnect switch. The variant code in the order number confirms this. ## Compliance and Documentation – What You'll Need for the File This drive carries a dense set of IEC and EN standards: IEC 61800-3 for EMC environments 1 and 2 (category C2 and C3), IEC 61800-5-1 for safety, IEC 61508 / 13849-1 for functional safety, plus IEC 60721-3 for climatic conditions. The integrated EMC filter meets radiated and conducted limits for category C2 up to 50 m cable, and C3 up to 150 m – that's a real advantage in panel layout because you often skip the external input filter. For documentation pack, you'll want the EC Declaration of Conformity covering all the listed standards; the distributor should provide it without a fight. Pollution degree 3 (conductive pollution) means the drive is designed for industrial environments but still benefits from clean air; if your installation sees humidity above 95% RH or conductive dust, you should supplement with panel ventilation and conformal coating on terminals. ## Mounting and Environment – Some Real Constraints Wall mount only, vertical within ±10°. Shock resistance 15 gn for 11 ms, vibration 1 gn up to 200 Hz – solid for pump/fan duty but not meant for direct engine mounting on a genset skid. Noise level 52 dB – you'll hear it in a quiet control room. Supply frequency tolerance is -5 to +5% of 50/60 Hz.","metaTitle":"Schneider Electric ATV650U15N4EU Altivar Process Drive, 0.75","metaDescription":"ATV650U15N4EU variable speed drive from Altivar Process ATV600 series. 0.75 kW heavy duty / 1.5 kW normal duty, 380-480 V, IP55, integrated EMC filter, STO SIL3. Current production","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Marking":"CE","Variant":"With disconnect switch","Category":"US1CP4E22205","Standards":"IEC 61800-3 environment 1 category C2 EN/IEC 61800-3 environment 2 category C3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 IEC 61800-3","EMC filter":"Integrated 164.04 ft (50 m) IEC 61800-3 category C2 Integrated 492.1 ft (150 m) IEC 61800-3 category C3","Noise level":"52 dB","Option card":"Slot A communication module, PROFINET Slot A communication module, DeviceNet Slot A communication module, Modbus TCP/EtherNet/IP Slot A communication module, CANopen daisy chain RJ45 Slot A communication module, CANopen SUB-D 9 Slot A communication module, CANopen screw terminals Slot A/slot B digital and analog I/O extension module Slot A/slot B output relay extension module Slot A communication module, Ethernet IP/Modbus TCP/MD-Link communication module, BACnet MS/TP communication module, Ethernet Powerlink Slot A communication module, Profibus DP V1","Line current":"2.6 A 480 V normal duty) 1.7 A 380 V heavy duty) 1.5 A 480 V heavy duty) 3 A 380 V normal duty)","Maximum THDI":"<48 % full load IEC 61000-3-12","Mounting Mode":"Wall mount","Motor power kW":"0.75 kW heavy duty) 1.5 kW normal duty)","Regulation loop":"Adjustable PID regulator","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"3","Range of Product":"Altivar Process ATV600","Shock resistance":"15 gn 11 ms IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV650","Relative humidity":"5...95 % without condensation IEC 60068-2-3","Operating altitude":"1000...4800 m with current derating 1 % per 100 m <= 3280.84 ft (1000 m) without derating","Operating position":"Vertical +/- 10 degree","Discrete input type":"DI7, DI8 programmable as pulse input 0...30 kHz, 24 V DC 1 MOhm 500 V DC for 1 minute to earth","Product destination":"Asynchronous motors Synchronous motors","Degree of protection":"UL type 12 UL 508C","Overvoltage category":"III","Vibration resistance":"1 gn (f= 13...200 Hz) conforming to IEC 60068-2-6 1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6","Discrete input number":"8","Nbr. of units in pkg.":"1","Nominal Output Current":"4.0 A","IP degree of protection":"IP55IEC 60529 IP55IEC 61800-5-1","Continuous output current":"2.2 A 4 kHz heavy duty 4 A 4 kHz normal duty","Product or Component Type":"Variable speed drive","[Us] rated supply voltage":"380...480 V","Maximum Horse Power Rating":"1 hp heavy duty 2 hp normal duty","Communication Port Protocol":"Modbus serial Modbus TCP","Product Specific Application":"Process and utilities","Speed drive output frequency":"0.1...500 Hz","Electromagnetic compatibility":"Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2","Ambient air transport temperature":"-40...158 °F (-40...70 °C)","Ambient Air Temperature for Storage":"-40...158 °F (-40...70 °C)","Ambient air temperature for operation":"104...122 °F (40...50 °C) (with derating factor) 5...104 °F (-15...40 °C) (without derating)","Environmental class (during operation)":"Class 3C3 according to IEC 60721-3-3 Class 3S3 according to IEC 60721-3-3","Relative symmetric mains voltage tolerance":"10 %","Permitted relative humidity (during operation)":"Class 3K5 according to EN 60721-3","Relative symmetric network frequency tolerance":"5 %","Maximum acceleration under shock impact (during operation)":"150 m/s² at 11 ms","Maximum deflection under vibratory load (during operation)":"1.5 mm at 2...13 Hz","Maximum acceleration under vibrational stress (during operation)":"10 m/s² at 13...200 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,885.00 – $3,014.59","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5ee442f757cbc3336bc96680b31f788b.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/ATV650U15N4EU/alternatives.json"},"ai":{"faq":[{"question":"What are the key compliance documents for this drive?","answer":"The drive is CE marked and complies with IEC 61800-3 (environment 1 category C2, environment 2 category C3), IEC 61800-5-1, IEC 61508, IEC 13849-1, and IEC 60721-3. The distributor should provide an EC Declaration of Conformity covering all listed standards. Additional RoHS and REACH documentation is available from the manufacturer upon request."},{"question":"Does this drive include a disconnect switch?","answer":"Yes. The variant identifier in the order code (ATV650U15N4EU, with the 'U' indicating disconnect switch) confirms that a factory-integrated disconnect switch is included. This allows a local lockout for safe maintenance without an external isolation device."},{"question":"What is the heavy-duty power rating?","answer":"Under heavy duty (constant torque) the drive is rated for 0.75 kW at 2.2 A continuous output current with a 4 kHz switching frequency. Normal duty (variable torque) allows 1.5 kW at 4.0 A."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV650U15N4EU","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV650U15N4EU when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}