{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV650U40N4","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV650U40N4","canonicalUrl":"https://aoctrl.com/schneider/ATV650U40N4","factsUrl":"https://aoctrl.com/api/mcp/products/ATV650U40N4","rawCanonicalId":null},"summary":{"shortDescription":"variable speed drive, Altivar Process ATV600, ATV650, 4kW, 400 to 480V, IP55","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Marking":"CE","Variant":"Standard version","Standards":"IEC 61800-3 IEC 61800-3 environment 1 category C2 EN/IEC 61800-3 environment 2 category C3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 UL 508C","EMC filter":"Integrated with 50 m conforming to IEC 61800-3 category C2 Integrated with 150 m conforming to IEC 61800-3 category C3","Noise level":"52 dB","Option card":"Slot A: communication module, PROFINET Slot A: communication module, DeviceNet Slot A: communication module, Modbus TCP/EtherNet/IP Slot A: communication module, CANopen daisy chain RJ45 Slot A: communication module, CANopen SUB-D 9 Slot A: communication module, CANopen screw terminals Slot A/slot B: digital and analog I/O extension module Slot A/slot B: output relay extension module Slot A: communication module, Ethernet IP/Modbus TCP/MD-Link Communication module, BACnet MS/TP Communication module, Ethernet Powerlink Slot A: communication module, Profibus DP V1","Line current":"5.1 A at 480 V (normal duty) 4.5 A at 380 V (heavy duty) 4 A at 480 V (heavy duty) 7.6 A at 380 V (normal duty)","Maximum THDI":"<48 % full load conforming to IEC 61000-3-12","Mounting mode":"Wall mount","Motor power hp":"5 hp normal duty","Motor power kW":"3 kW (heavy duty) 4 kW (normal duty)","Regulation loop":"Adjustable PID regulator","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Pollution degree":"3","Range of product":"Altivar Process ATV600","Shock resistance":"15 gn for 11 ms conforming to IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV650","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Operating altitude":"1000...4800 m with current derating 1 % per 100 m <= 1000 m without derating","Operating position":"Vertical +/- 10 degree","Discrete input type":"DI7, DI8 programmable as pulse input: 0...30 kHz, 24 V DC ( 1 MOhm 500 V DC for 1 minute to earth","Product destination":"Asynchronous motors Synchronous motors","Overvoltage category":"III","Vibration resistance":"1 gn (f= 13...200 Hz) conforming to IEC 60068-2-6 1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6","Discrete input number":"8","Nominal Output Current":"9.3 A","IP degree of protection":"IP55 conforming to IEC 60529 IP55 conforming to IEC 61800-5-1","Continuous output current":"5.6 A at 4 kHz for heavy duty 9.3 A at 4 kHz for normal duty","Product or component type":"Variable speed drive","[Us] rated supply voltage":"380...480 V","Communication port protocol":"Modbus TCP Modbus serial Modbus serial","Product specific application":"Process and utilities","Speed drive output frequency":"0.1...500 Hz","Electromagnetic compatibility":"Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2","Ambient air transport temperature":"-40...70 °C","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"40...50 °C (with derating factor) -15...40 °C (without derating)","Environmental class (during operation)":"Class 3C3 according to IEC 60721-3-3 Class 3S3 according to IEC 60721-3-3","Relative symmetric mains voltage tolerance":"10 %","Permitted relative humidity (during operation)":"Class 3K5 according to EN 60721-3","Relative symmetric network frequency tolerance":"5 %","Maximum acceleration under shock impact (during operation)":"150 m/s² at 11 ms","Maximum deflection under vibratory load (during operation)":"1.5 mm at 2...13 Hz","Maximum acceleration under vibrational stress (during operation)":"10 m/s² at 13...200 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e638201a6cf99dc31103c9f751339462.pdf","sourceUrl":"https://www.se.com/ie/en/product/ATV650U40N4/variable-speed-drive-altivar-process-atv600-atv650-4kw-400-to-480v-ip55/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ATV650U40N4/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV650U40N4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV650U40N4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}