{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV6A0C13N6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV6A0C13N6","canonicalUrl":"https://aoctrl.com/schneider/ATV6A0C13N6","factsUrl":"https://aoctrl.com/api/mcp/products/ATV6A0C13N6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV600, modular version, ATV6A0C13N6, 90 kW at 500 V normal duty, 75 kW heavy duty, integrated EMC filter C3, STO SIL 3.","salesMarkdown":"The ATV6A0C13N6 is a modular Altivar Process ATV600 drive sized for a 90 kW motor at 500 V normal duty (75 kW heavy duty). Line current draws 129 A normal duty, 110 A heavy duty at 500 V. Integrated EMC filter meets IEC 61800-3 category C3 for 300 m cable runs — no external filter needed for most industrial installations. Switching frequency adjustable 2 to 4.9 kHz with derating; for the full 90 kW output, stay at the lower end of that range. Safe torque off (STO) is built in to SIL 3, covering both motor and drive thermal protection, phase loss, overcurrent, and DC bus overvoltage. The modular build means slot A and slot B accept communication or I/O extension cards — Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, CANopen, plus digital/analog I/O or relay expansion. ## Fieldbus and integration Two-wire RS-485 Modbus serial runs at 4.8 to 38.4 kbit/s, RTU frame, up to 247 addresses. Ethernet/Modbus TCP handles 10/100 Mbit/s with half/full duplex autonegotiation. The control removable screw terminals accept 0.5 to 1.5 mm² (AWG 20–16). For the power connection, line side uses screw terminals; motor side uses M10 bars. Mounting is cabinet-mount, UL Type 1 or 12 per UL 61800-5-1 when integrated into a cabinet. Pollution degree 2 per IEC 61800-5-1. Vibration resistance 1.5 mm peak-to-peak at 2–13 Hz, 0.5 gn at 13–200 Hz. Marked CE. Complies with IEC 61800-3 (EMC), IEC 61800-5-1 (safety), IEC 61000-3-12 (harmonics), IEC 60721-3 (environmental), IEC 61508 and IEC 13849-1 (functional safety). Prospective line Isc rated 50 kA. Noise level 69 dB per 86/188/EEC.","metaTitle":"ATV6A0C13N6 Altivar Process ATV600, 90 kW at 500 V normal du","metaDescription":"ATV6A0C13N6 is a modular Altivar Process ATV600 drive from Schneider Electric. Rated 90 kW at 500 V normal duty, 75 kW heavy duty. Integrated EMC filter C3, STO SIL 3, current life","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drives (VFD)"],"specifications":{"title":"ATV6A0C13N6","Marking":"CE","Variant":"Modular version","Standards":"IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1","EMC filter":"Integrated 984.3 ft (300 m) IEC 61800-3 category C3","Data format":"8 bits, configurable odd, even or no parity Modbus serial","Noise level":"69 dB 86/188/EEC","Option card":"Slot A communication module, Profibus DP V1 Slot A communication module, PROFINET Slot A communication module, DeviceNet Slot A communication module, Modbus TCP/EtherNet/IP Slot A communication module, CANopen daisy chain RJ45 Slot A communication module, CANopen SUB-D 9 Slot A communication module, CANopen screw terminals Slot A/slot B digital and analog I/O extension module Slot A/slot B output relay extension module","description":"Variable speed drive, Altivar Process ATV600, APM, single 500 V, 90 kW","Line current":"129.0 A 500 V normal duty) 110.0 A 500 V heavy duty)","Maximum THDI":"<48 % full load IEC 61000-3-12","Exchange mode":"Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP","Mounting mode":"Cabinet mount","Apparent power":"112 kVA at 500 V normal duty 95 kVA at 500 V heavy duty","Motor power kW":"90.0 kW at 500 V normal duty 75.0 kW at 500 V heavy duty","Output voltage":"<= power supply voltage","Kit composition":"1 control unit mechanical mounting kits power connection set of fuses 1.0 power module 200 kW","Protection type":"Thermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Method of access":"Slave Modbus TCP","Pollution degree":"2 IEC 61800-5-1","Range of product":"Altivar Process ATV600","Shock resistance":"4 gn 11 ms IEC 60068-2-27","Supply frequency":"50...60 Hz - 5...5 %","Device short name":"ATV6A0","Relative humidity":"5...95 % without condensation IEC 60068-2-3","Transmission rate":"10/100 Mbit/s Ethernet IP/Modbus TCP 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial","Operating altitude":"< 2000 m with current derating above 1000m","Physical interface":"2-wire RS 485 Modbus serial","Transmission frame":"RTU Modbus serial","Number of addresses":"1...247 Modbus serial","Product destination":"Synchronous motors Asynchronous motors","Switching frequency":"2...4.9 kHz adjustable with derating factor","Degree of protection":"UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)","Frequency resolution":"Display unit 0.1 Hz Analog input 0.012/50 Hz","Prospective line Isc":"50 kA","Type of polarization":"No impedance Modbus serial","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Braking to standstill":"By DC injection","Electrical connection":"Control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 Line side screw terminal Motor M10 x 2 bars","Power dissipation in W":"Forced convection 2410 W 2.5 kHz normal duty) Forced convection 2090 W 2.5 kHz heavy duty)","IP degree of protection":"IP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529","Motor slip compensation":"Can be suppressed Adjustable Automatic whatever the load Not available in permanent magnet motor law","Number Of Preset Speeds":"16 preset speeds","Network number of phases":"3 phases","Continuous output current":"145.0 A at 2.5 kHz normal duty 125.0 A at 2.5 kHz heavy duty","Maximum transient current":"159.5 A 60 s normal duty) 187.5 A 60 s heavy duty)","Product or component type":"Variable speed drive","[Us] rated supply voltage":"500 V - 10...15 %","Communication port protocol":"Ethernet Modbus serial Modbus TCP","Nominal switching frequency":"2.5 kHz","Environmental characteristic":"Chemical pollution resistance class 3C3 IEC 60721-3-3 Dust pollution resistance class 3S3 IEC 60721-3-3 Humidity resistant class 3K3 IEC 60721-3-3","Product specific application":"Process and utilities","Speed drive output frequency":"0...500 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Synchronous motor control profile":"Permanent magnet motor Synchronous reluctance motor","Asynchronous motor control profile":"Constant torque standard Variable torque standard Optimized torque mode","Acceleration and deceleration ramps":"S, U or customized Linear adjustable separately from 0.01...9999 s","Ambient air temperature for storage":"-40...158 °F (-40...70 °C)","Permissible temporary current boost":"1.1 x In 60 s normal duty) 1.5 x In 60 s heavy duty)","Ambient air temperature for operation":"14...104 °F (-10...40 °C) without derating 104...122 °F (40...50 °C) with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/th/en/product/ATV6A0C13N6/variable-speed-drive-altivar-process-atv600-apm-single-500-v-90-kw/"},"ai":{"faq":[{"question":"What are the key power ratings for the ATV6A0C13N6?","answer":"Motor power is 90 kW at 500 V normal duty, 75 kW at 500 V heavy duty. Line current is 129 A normal duty, 110 A heavy duty at 500 V. Apparent power is 112 kVA normal duty, 95 kVA heavy duty at 500 V."},{"question":"What safety functions does the ATV6A0C13N6 include?","answer":"It includes Safe Torque Off (STO) to SIL 3, plus thermal protection, motor phase break, overcurrent, short-circuit, DC bus overvoltage, line supply over/undervoltage, phase loss, and overspeed protection."},{"question":"What communication options are available for the ATV6A0C13N6?","answer":"It has built-in Modbus serial (RS-485, RTU, 4.8–38.4 kbit/s) and Modbus TCP (10/100 Mbit/s). Slot A accepts Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, or CANopen modules. Slot A/B accept digital/analog I/O or relay expansion."},{"question":"What compliance documentation is available for the ATV6A0C13N6?","answer":"The drive is CE marked and complies with IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1. UL Type 1 and Type 12 per UL 61800-5-1 when cabinet-integrated."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV6A0C13N6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV6A0C13N6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}